Well Yield, Pump Flow & Cistern Buffer Calculator
Enter documented sustained yield and pump-to-cistern flow. Define up to five demand blocks and each plan's permitted transfer windows. Track accepted water, unmet demand, unused transfer opportunity and ending storage.
Compare well yield and cistern demand buffers
Track what both cistern plans can deliver when demand and pump transfer change through the schedule.
Only Plan B covers every demand block.
186 US gal requested over 165 min · documented well yield 1.5 US gal/min.
Plan A
16.5 US gal unmet
Delivered 169.5 US gal · lowest stored 0 US gal.
Closing storage 60 US gal of 60 US gal usable capacity.
Starting storage restored or exceeded.
Unused transfer opportunity 63 US gal.
Plan B
0 US gal unmet
Delivered 186 US gal · lowest stored 7.5 US gal.
Closing storage 100 US gal of 100 US gal usable capacity.
Starting storage restored or exceeded.
Unused transfer opportunity 6.5 US gal.
Usable cistern storage through the schedule
Reconcile the accepted water
45 US gal starting + 184.5 US gal transferred = 169.5 US gal delivered + 60 US gal ending.
Edit documented well and cistern values
Use the same volume unit for every rate and amount. Enter starting storage and capacity above the same usable empty boundary.
Edit demand blocks and transfer windows
Review exact transfer and storage calculations
Plan A
Block 1 · minute 0 to 30
Potential transfer 3/2 US gal/min · requested 6 US gal.
Balance 45 + 21 = 6 + 60 US gal.
Unmet 0 US gal · unused transfer 24 US gal.
Full at exact minute 150/13.
Block 2 · minute 30 to 75
Potential transfer 3/2 US gal/min · requested 144 US gal.
Balance 60 + 135/2 = 255/2 + 0 US gal.
Unmet 33/2 US gal · unused transfer 0 US gal.
Empty at exact minute 1110/17.
Block 3 · minute 75 to 165
Potential transfer 3/2 US gal/min · requested 36 US gal.
Balance 0 + 96 = 36 + 60 US gal.
Unmet 0 US gal · unused transfer 39 US gal.
Full at exact minute 1425/11.
Plan B
Block 1 · minute 0 to 30
Potential transfer 3/2 US gal/min · requested 6 US gal.
Balance 45 + 45 = 6 + 84 US gal.
Unmet 0 US gal · unused transfer 0 US gal.
Block 2 · minute 30 to 75
Potential transfer 3/2 US gal/min · requested 144 US gal.
Balance 84 + 135/2 = 144 + 15/2 US gal.
Unmet 0 US gal · unused transfer 0 US gal.
Block 3 · minute 75 to 165
Potential transfer 3/2 US gal/min · requested 36 US gal.
Balance 15/2 + 257/2 = 36 + 100 US gal.
Unmet 0 US gal · unused transfer 13/2 US gal.
Full at exact minute 1750/11.
Show cistern CSV text
How to use this calculator
- Enter the documented well yield and matching volume unit.
- Copy the documented actual pump-to-cistern rate, usable tank capacity and starting usable amount for each plan.
- Enter timed demand blocks and whether each plan can transfer in each block.
- Inspect empty/full contacts, unmet use and whether ending storage recovers.
- Download the block-by-block mass balance and the entered schedule.
The Formula
The mathematical logic powering this calculation is:
Use one volume basis throughout, US gallons or liters. Enter a documented sustained source yield and separate documented pump-to-cistern rate for each plan. In an enabled block, potential inflow rate is the smaller of those two entered rates. In a paused block it is zero. Each block has its own constant entered water demand per minute.
The starting usable amount and capacity are measured relative to the same usable empty and full reference. Before limits, ending storage equals starting storage + (potential inflow rate − demand rate) × block duration. At the upper limit, excess potential flow is unused transfer opportunity. At the lower limit, demand beyond concurrent replenishment cannot be met. Contact time is the exact start-to-boundary distance divided by the net rate. Equality at the last instant records the boundary even when no water is curtailed or unmet.
Each block and each whole plan reconcile starting storage + accepted transfer = ending storage + delivered demand. Accepted transfer is the potential less unused transfer opportunity. Delivered demand is the request less unmet demand. The ending amount also indicates whether the modeled schedule returns to its starting storage.
Use documented inputs and a measured demand scenario. The model compares 2–5 blocks totaling at most 1,440 minutes. It uses exact rational arithmetic for amount, transfer and event times. Flow is treated as constant within each enabled block and does not change with equipment head, well water level or tank level. The schedule tracks the downstream usable tank volume. Aquifer assessment, pump selection, controls, pressure-vessel design, water quality and installation are separate.Worked Example
If you input:
- Documented source: 1.5 US gal/min
- Demand blocks: 30 min at 0.2, 45 min at 3.2, 90 min at 0.4 US gal/min
- Plans: 60 and 100 usable US gal, both starting at 45; documented transfer rates 1.5 and 2.0 US gal/min
Result:
Both transfer rates are capped at 1.5 US gal/min. Plan A leaves 16.5 US gal unmet and later refills. Plan B covers the entire 186 US gal demand and ends at 100 US gal.
Frequently Asked Questions
Why is rated pump transfer different from well yield?
The transfer restriction is the lower of the two entered documented rates. A larger pump flow number by itself does not raise the sustained source yield.
Does unused transfer opportunity mean the tank overflowed?
It is the amount of modeled potential supply that could not enter full usable storage after meeting simultaneous demand.
Can demand still be served when usable storage is zero?
Yes. A permitted inflow can meet some or all demand while the usable tank inventory stays at zero.
Does ending above the starting volume mean every block succeeded?
A supply can recover after an earlier shortage. Read unmet demand and ending storage separately.
Does the worksheet determine a well’s sustainable yield?
Enter an already established yield for the planned conditions. The comparison models the entered rate and schedule.
Similar Calculators
Water Well Volume, Storage & Drawdown Calculator
Calculate water in a uniform or stepped well bore. Compare static and pumping levels, volume above the intake, and a measured discharge trial.
Pump Curve & Operating Point Planner
Compare pump curves and speeds against system head. Visualize operating flow, runtime, electrical energy and whether your target volume fits the available hours.
Tank Volume & Dip Chart Calculator
Find tank volume from liquid depth or solve depth from volume. Compare fill levels and export dip charts for horizontal cylinders, upright cylinders and boxes.
Compressed Air Demand & Receiver Planner
Compare compressor CFM and receiver storage against timed demand. Visualize pressure reserve, recharge and unserved air, with exact stage ledgers and CSV export.
Well Pressure Tank Size & Pump Cycle Calculator
Compare well pressure tanks by usable drawdown, zero-demand refill time and starts per hour. See which tank count meets entered pump targets.