Well Pressure Tank Size & Pump Cycle Calculator

Compare two tank banks at the same pressure-switch band using published or measured drawdown. Enter pump delivery, documented cycle targets and steady water demand. Inspect the first two drawdown and refill cycles and find the demand where starts per hour peak. Use the exact minimum tank count for each entered per-tank capacity to check quoted options.

Well pressure tanks

Compare pressure tank drawdown and pump cycling

Both tank banks meet the entered targets.

8 US gal of usable drawdown meets both targets. Runtime needs 8 gal and the cycling limit needs 8 gal.

Tank bank A

8 US gal usable

Nominal volume
26.7 US gal
Zero-demand refill
60 s · meets target
Peak cycling
15 starts/h · within limit
Minimum count at entered drawdown per tank
1

Tank bank B

10.8 US gal usable

Nominal volume
40 US gal
Zero-demand refill
81 s · meets target
Peak cycling
≈11.1111 starts/h · within limit
Minimum count at entered drawdown per tank
2
Edit pump, demand and tank banks

Use the same pressure-switch band for the pump flow and both drawdown figures. Use motor or controller documentation for the targets.

Tank bank A
Tank bank B

Usable water through a pump cycle

Each bank starts at the upper switch point. Falling lines show drawdown. Rising lines show refill.

  • Tank bank A
  • Tank bank B
Usable water by elapsed time for both tank banksThe first two cycles for each cycling bank share an elapsed-time scale. The ledger lists cycle phases and times.Usable water · 10.8 gal at top011.52Elapsed time (min)

Tank bank A

Pump off
≈2.6667 min
Pump on
1.6 min
Repeating starts
14.0625/h

Tank bank B

Pump off
3.6 min
Pump on
2.16 min
Repeating starts
≈10.4167/h

Where starts per hour peak

Peak cycling occurs at 4 US gal/min, half the pump delivery.

  • Tank bank A
  • Tank bank B
Sustained starts per hour by steady water demandBoth curves peak at half the pump delivery. The horizontal amber line is the entered limit of 15 starts per hour.Starts per hour · 16.2 at top08Steady demand (US gal/min)

Amber dashes show the entered 15 starts/h limit. Open circles mark the selected demand while cycling.

Show tank comparison CSV text

How to use this calculator

  1. Enter the documented pump delivery and the manufacturer’s minimum run time and maximum starts per hour.
  2. Enter both banks’ tank counts and nominal volumes. Use ratings or measurements for usable drawdown at the same pressure-switch band.
  3. Enter a representative steady demand. Read off-time, refill time and the peak of the starts-per-hour curve.
  4. Compare each entered bank with the minimum whole tank count and save the exact cycle ledger.

The Formula

The mathematical logic powering this calculation is:

Each bank uses identical tanks sharing one pressure-switch band. Multiply the count by the published or measured usable drawdown per tank to get bank drawdown V in US gallons. Enter pump delivery Q in US gallons per minute across the same band. The shortest modeled refill occurs at zero water demand and lasts 60 × V ÷ Q seconds. To meet an entered minimum run time T in seconds, the bank needs drawdown Q × T ÷ 60.

With steady demand D strictly between zero and Q, off time is V ÷ D minutes and on time is V ÷ (Q − D) minutes. The repeating starts per hour equal 60 divided by the sum of those times, or 60 × D × (Q − D) ÷ (V × Q). This quadratic peaks at D = Q ÷ 2. Peak starts per hour are 15 × Q ÷ V. To meet an entered maximum of S starts per hour, drawdown must be at least 15 × Q ÷ S. Use the larger of the two drawdown requirements. The minimum whole tank count is that volume divided by usable drawdown per tank, rounded up. Exact equality meets either target.

The trace begins at the upper switch point with the pump off and shows two cycles for each bank when cycling is possible. With zero demand the modeled bank stays full. At demand equal to Q, the pump starts after the reserve empties and stays on with no refill. At demand above Q the model also shows unmet flow D − Q after cut-in. The chart tracks usable water above cut-in. Treat pressure band, pump flow and the entered targets as fixed documented quantities. Actual flow can change with head, drawdown and pressure. Use the worksheet to compare documented tanks and targets for a fixed-speed, pressure-switch system.

Pump flow is 0.01–1,000 US gal/min, demand 0–2,000 US gal/min, minimum run time 1–3,600 seconds, and maximum starts 0.01–3,600 per hour. Enter one to 64 identical tanks in each bank and 0.01–10,000 US gal per tank for both documented usable drawdown and nominal volume. Nominal volume contains the usable drawdown. Decimals are evaluated exactly through 12 places. The examples illustrate a hard numerical boundary. Use the resolution supported by your records for planning.

Worked Example

If you input:

  • Pump delivery and targets: 8 US gal/min, at least 60 seconds per run, at most 15 starts/h
  • Tank bank A: One tank with 8 US gal of usable drawdown
  • Tank bank B: Two tanks with 5.4 US gal of usable drawdown each
  • Steady demand: 3 US gal/min

Result:

Both banks meet the targets. Bank A refills in exactly 60 seconds at zero demand and peaks at exactly 15 starts/h at 4 US gal/min of demand. Bank B has 10.8 US gal of usable drawdown and peaks at about 11.1111 starts/h.

Frequently Asked Questions

What does usable drawdown mean?

It is the quantity of water available between the pump stopping and starting pressure for the chosen band. Look up the drawdown for your exact tank and that pressure band or use a documented measurement.

Why is the highest cycling frequency at half the pump delivery?

At light demand the bank empties slowly. As demand approaches pump delivery it refills slowly. Half the pump delivery minimizes the sum of off and on times in this constant-flow model.

Can a large demand result in fewer starts?

Yes. As demand approaches the pump delivery, each refill takes longer. At equal or greater demand the pump stays on once the bank empties. Greater demand also creates a flow deficit.

Where do I find the targets?

Use the stated limits for the installed motor, pump or controller and rating conditions. The example values illustrate the calculation.

How do I compare two tank models on the same quote?

Use the two bank entries to compare alternatives. Each bank represents identical tanks at one pressure band. Check model-specific operating conditions and configuration with the manufacturer's documentation.