Tank Volume & Dip Chart Calculator
Turn liquid depth into tank volume, compare a target level, and build a reusable dip chart from your tank’s inside dimensions.
See how depth becomes volume
Translate a measured level into contents, compare another level and build a theoretical dip chart.
Try a tank
Tank and current level
Use inside dimensions and a level liquid surface. The horizontal cylinder has flat ends and a horizontal axis.
Each mode keeps its own entry; switching may change the level. Percentage refers to volume, not height.
Compare a level or a depth scenario
A comparison you choose, not a recommended operating limit or a filling instruction.
A lower and upper depth around your entered level. This is not a confidence interval.
≈ 1,842.55 L of liquid at 0.5 m depth; ≈ 19.5501% of the tank’s volume.
Liquid volume
≈ 1,842.55 L
Geometric capacity: ≈ 9,424.78 L
Volume filled
≈ 19.5501%
Volume fraction, not percentage of height.
Liquid depth
0.5 m
Distance below the top: 1.5 m
Unfilled geometric volume
≈ 7,582.22 L
Geometric space only; not an approved working capacity.
Your target comparison
75% corresponds to ≈ 7,068.58 L at ≈ 1.40397 m depth.
Target − current: ≈ 5,226.03 L. The target contains more liquid than the current level.
This compares two levels; it is not an instruction to fill or drain the tank.
Depth scenario range
0.49 m to 0.51 m gives ≈ 1,790.77 L to ≈ 1,894.69 L.
Deterministic depth-scenario range, clipped to the tank. It is not a confidence interval.
See the level and its volume
- Current reading
- Target
- Depth scenario band
Circular end cross section; both axes are in metres with equal physical scales. Equal physical scales; shaded liquid does not represent a safe operating limit.
The horizontal-cylinder curve is nonlinear: equal depth increments hold different volumes. Upright cylinders and boxes give a straight line. Points closer than a pixel may overlap; inspect their values below.
Tank levels and dip chart
Includes empty and full, with up to 501 rows. A shorter final interval is retained; the increment is never silently increased.
21 theoretical readings, including both endpoints. These ideal geometric values are not a certified tank calibration.
Inspection adds a square marker to both diagrams without changing the current reading.
View all 21 dip readings
| Row | Liquid depth | Liquid volume | Volume filled | Unfilled volume | Depth interval | Volume in interval | Inspect |
|---|---|---|---|---|---|---|---|
| 0 · Empty | 0 m | 0 L | 0% | ≈ 9,424.78 L | — | — | |
| 1 | 0.1 m | ≈ 176.178 L | ≈ 1.8693% | ≈ 9,248.6 L | 0.1 m | ≈ 176.178 L | |
| 2 | 0.2 m | ≈ 490.503 L | ≈ 5.2044% | ≈ 8,934.27 L | 0.1 m | ≈ 314.326 L | |
| 3 | 0.3 m | ≈ 886.497 L | ≈ 9.40602% | ≈ 8,538.28 L | 0.1 m | ≈ 395.993 L | |
| 4 | 0.4 m | ≈ 1,341.89 L | ≈ 14.2378% | ≈ 8,082.89 L | 0.1 m | ≈ 455.389 L | |
| 5 | 0.5 m | ≈ 1,842.55 L | ≈ 19.5501% | ≈ 7,582.22 L | 0.1 m | ≈ 500.669 L | |
| 6 | 0.6 m | ≈ 2,378.02 L | ≈ 25.2316% | ≈ 7,046.76 L | 0.1 m | ≈ 535.466 L | |
| 7 | 0.7 m | ≈ 2,939.77 L | ≈ 31.1919% | ≈ 6,485.01 L | 0.1 m | ≈ 561.745 L | |
| 8 | 0.8 m | ≈ 3,520.44 L | ≈ 37.353% | ≈ 5,904.34 L | 0.1 m | ≈ 580.672 L | |
| 9 | 0.9 m | ≈ 4,113.39 L | ≈ 43.6444% | ≈ 5,311.39 L | 0.1 m | ≈ 592.953 L | |
| 10 | 1 m | ≈ 4,712.39 L | 50% | ≈ 4,712.39 L | 0.1 m | ≈ 598.998 L | |
| 11 | 1.1 m | ≈ 5,311.39 L | ≈ 56.3556% | ≈ 4,113.39 L | 0.1 m | ≈ 598.998 L | |
| 12 | 1.2 m | ≈ 5,904.34 L | ≈ 62.647% | ≈ 3,520.44 L | 0.1 m | ≈ 592.953 L | |
| 13 | 1.3 m | ≈ 6,485.01 L | ≈ 68.8081% | ≈ 2,939.77 L | 0.1 m | ≈ 580.672 L | |
| 14 | 1.4 m | ≈ 7,046.76 L | ≈ 74.7684% | ≈ 2,378.02 L | 0.1 m | ≈ 561.745 L | |
| 15 | 1.5 m | ≈ 7,582.22 L | ≈ 80.4499% | ≈ 1,842.55 L | 0.1 m | ≈ 535.466 L | |
| 16 | 1.6 m | ≈ 8,082.89 L | ≈ 85.7622% | ≈ 1,341.89 L | 0.1 m | ≈ 500.669 L | |
| 17 | 1.7 m | ≈ 8,538.28 L | ≈ 90.594% | ≈ 886.497 L | 0.1 m | ≈ 455.389 L | |
| 18 | 1.8 m | ≈ 8,934.27 L | ≈ 94.7956% | ≈ 490.503 L | 0.1 m | ≈ 395.993 L | |
| 19 | 1.9 m | ≈ 9,248.6 L | ≈ 98.1307% | ≈ 176.178 L | 0.1 m | ≈ 314.326 L | |
| 20 · Full | 2 m | ≈ 9,424.78 L | 100% | 0 L | 0.1 m | ≈ 176.178 L |
View CSV text
The same text is used for the download. Focus this field to select all of it, then copy with your usual keyboard shortcut.
Full calculation values and inverse-depth details
| Quantity | Calculation value | Exact value or expression (units stated) |
|---|---|---|
| Capacity | 9424.77796076938 L (approximate) | (3) × π m³ (expression in SI units) |
| Liquid depth | 0.5 m | 1/2 m (exact) |
| Distance below top | 1.5 m | 3/2 m (exact) |
| Liquid volume | 1842.5545479131356 L (approximate) | Approximate numerical result |
| Unfilled volume | 7582.223412856244 L (approximate) | Approximate numerical result |
| Volume filled | 19.550110947788536 % (approximate) | Approximate numerical result |
| Volume unfilled | 80.44988905221146 % (approximate) | Approximate numerical result |
Method, assumptions and sources
This is a theoretical geometry planner for inside dimensions, a level liquid surface and ideal flat-ended shapes. It does not account for tilt, dished ends, fittings, deformation or real-tank calibration. It does not establish safe working levels or provide fuel-handling instructions.
The horizontal cylinder uses a circular-segment integral; upright cylinders and boxes use constant cross-sectional area. Small filled and empty caps are retained separately. Near-full results can be shown as capacity minus a small remaining volume instead of falsely appearing full.
OpenStax’s volume-by-slicing method explains the cross-sectional integral and the constant-area cylinder case.
Entries support up to 16 significant digits and 12 effective decimal places. Inside dimensions range from 0.001 to 1000 m. Unsupported precision or unresolved numerical boundaries return an error. Unit changes preserve physical entries and require all affected retained drafts to be valid, including inactive ones.
- Inside clear dimensions of one ideal level tank. Horizontal cylinders have flat ends and a horizontal axis.
- Depth is measured vertically from the inside bottom. Percentage is liquid volume divided by capacity, not percentage of height.
- No tilt, dished heads, internal displacement, temperature correction, calibration allowance or safe operating fill limit is inferred.
- Unit factors are exact: US liquid gallon 0.003785411784 m³; Imperial gallon 0.00454609 m³; international foot 0.3048 m.
- The theoretical table includes empty and full. A nondividing increment leaves a shorter final interval; current and target markers are separate.
- Rational input boundaries are checked before numerical conversion. Irrational outputs and inverse depths are numerical approximations; their precision does not certify the measurements.
Compute geometric capacity
C = π × (inside diameter / 2)² × axial length or heightMap depth to volume
V(h) = L ∫₀ʰ 2√(Dy − y²) dy; evaluate the smaller liquid or empty cap directly.Solve a known volume or percentage
Use the smaller fill fraction and a bounded monotone inverse. Retain liquid depth and freeboard independently.Build the dip chart
Depths 0, increment, 2 × increment, …, full height. Integrate each interval directly so a small final volume remains positive.NBS Circular C416 (1937) documents the flat-ended horizontal-cylinder dip-table convention. Its rounded historical tables are not a certification of this calculation or your tank.
NIST SP1038 gives the exact inch and US gallon definitions; NIST’s foot table distinguishes the international foot. NIST SP811 lists the Imperial gallon and litre conversions. US liquid and Imperial gallons are separate units here.
How to use this calculator
- Choose a horizontal cylinder with flat ends, an upright cylinder or a rectangular box. Select length and volume units, then enter inside dimensions. For a horizontal cylinder, length is along the tank axis; depth is measured vertically from the lowest inside bottom.
- Choose the known measurement: liquid depth, liquid volume or volume filled (%). Enter that reading and inspect the resulting contents, depth, distance below the top and unfilled geometric volume. Each reading mode retains its own entry; switching modes may change the current level.
- Optionally compare a target volume percentage and a depth scenario band. The target is your comparison, not a recommended operating limit. Review any clipping of the band at empty or full, especially when it surrounds a depth inferred from volume.
- Inspect the equal-scale tank section and the depth-versus-volume curve. For horizontal cylinders, note that a quarter of the height is less than a quarter of the capacity. Selecting a dip-chart row changes only the inspection marker, not your current reading.
- Enter a dip-chart depth increment. The chart includes empty and full and allows at most 501 rows. Correct an invalid or too-small increment before exporting the complete CSV; the valid main calculation remains available. Download the file or select the identical CSV text.
The Formula
The mathematical logic powering this calculation is:
Let h be liquid depth from the inside bottom, H the full inside height, r the inside radius and L the tank length. All tanks are level, with flat ends or bases.
Horizontal cylinder: H = 2r, capacity C = πr²L, and V(h) = L[r² arccos((r − h)/r) − (r − h)√(2rh − h²)]. Equivalently, V(h) = 2L ∫₀ʰ √(2ry − y²) dy. The calculation evaluates small liquid or empty segments directly instead of subtracting nearly equal rounded quantities.
Upright cylinder: C = πr²H and V(h) = πr²h. Rectangular box: C = WLH and V(h) = WLh. Volume filled (%) = 100V/C; this equals percentage of height only for the upright cylinder and box.
Known volume or volume percentage determines h by inversion. Horizontal inversion solves the smaller liquid/empty segment with a bounded bracket; a numerical limit is reported when the requested precision cannot be resolved. Empty volume and distance below the top are retained separately.
A target percentage p has target volume pC/100. Its signed difference is target volume − current volume. A depth scenario half-width t gives effective depths max(0,h − t) and min(H,h + t), with each clipped endpoint identified. This range is a geometry scenario, not a confidence interval.
For positive dip increment s, rows are 0, s, 2s, … up to H, with H appended once when needed. Row count = ceil(H/s) + 1, limited to 501. The last interval may be shorter; interval volumes are evaluated without losing a tiny positive final segment. No increment is silently coarsened.
Exact unit definitions: 1 ft = 0.3048 m; 1 in = 0.0254 m; 1 L = 0.001 m³; 1 US liquid gallon = 0.003785411784 m³; 1 Imperial gallon = 0.00454609 m³. Cylinder geometry and inverse results remain numerical approximations, even though these conversion factors are exact.Worked Example
If you input:
- Tank shape: Horizontal cylinder · flat ends
- Length unit: Metres
- Volume unit: Litres
- Inside diameter: 2
- Inside length: 3
- Known measurement: Liquid depth
- Liquid depth from bottom: 0.5
- Compare target: Yes
- Target volume filled (%): 75
- Include depth scenario band: Yes
- Depth scenario half-width: 0.01
- Dip-chart depth increment: 0.1
Result:
A level horizontal cylinder with inside diameter 2 m and length 3 m has capacity 3π m³, about 9,424.777961 L. At depth 0.5 m, its liquid volume is π − 3√3/4 m³, about 1,842.554548 L: 19.5501% of capacity, even though the depth is 25% of the diameter. The distance below the top is 1.5 m and unfilled volume is about 7,582.223413 L. A 0.1 m dip increment produces 21 rows, including 0 and 2 m. The enabled 75% target and ±0.01 m depth band are editable comparisons, not safe-fill limits or confidence intervals.
Frequently Asked Questions
Which tank dimensions and shapes does this support?
Use inside clear dimensions for one ideal tank: a level horizontal circular cylinder with flat ends, an upright circular cylinder with a flat base, or a rectangular box. Liquid depth is vertical from the inside bottom. For a horizontal cylinder, the diameter is its full height and the length runs along its axis. Tilt, domed or dished ends, conical bottoms, internal fittings, baffles, distortion and tank-specific calibration corrections are not inferred from these dimensions.
Why is a quarter-depth horizontal tank less than a quarter full?
Near the bottom of a circular section, each small increase in depth spans a narrow strip. The strip becomes wider toward the middle, so equal depth increments add different volumes. At one quarter of the diameter, an ideal horizontal cylinder contains approximately 19.5501% of its capacity. At half its diameter it contains half its capacity. Upright cylinders and boxes have a constant horizontal cross-sectional area, so their volume percentage equals their height percentage.
Can I find liquid depth from a known volume or percentage?
Yes. Choose Liquid volume or Volume filled (%) as the known measurement. Percentage refers to volume, not height. The horizontal-cylinder calculation solves the monotonic volume relation; the other two shapes have a linear depth relation. Each mode keeps its own draft, so switching modes can change the current reading. A numerical solver limit is reported explicitly rather than presenting its last iteration as a solved depth.
Is this a certified tank calibration or a safe filling limit?
No. The dip chart is a theoretical relationship for the selected ideal geometry and your dimensions. It does not establish actual tank capacity, usable reserve, operating limits, product compatibility or a legal-for-trade calibration. Temperature, deformation, inclination and displaced volume can change a real tank's relationship. The optional target is an editable comparison, not a recommended level or an instruction to operate equipment.
What do the target and depth scenario band mean?
The target gives the volume and depth corresponding to your selected percentage of capacity. Its signed volume difference is target minus current; a negative difference means the target is below the current volume. A depth band recalculates the geometry at the current depth minus and plus your entered half-width. The effective endpoints are clipped at empty and full with explicit flags. In volume or percentage mode the band surrounds the inferred depth. It is not a statistical confidence interval or a measurement of tank accuracy.
How are dip-chart rows and the last interval generated?
Rows begin at zero and advance by your positive depth increment. The full inside height appears once even when the increment does not divide it, so the final interval may be shorter. An increment greater than the tank height gives the two endpoints. There may be at most 501 rows; an excessive request produces a table error and does not silently change your increment. Current calculations and the fixed-resolution curve remain available, but the complete CSV is unavailable until the table is valid. Inspecting a row does not overwrite the current reading.
Do unit changes preserve the tank and distinguish gallon types?
Length and volume unit changes preserve physical entries using the exact conversion definitions, including retained drafts for other shapes or reading modes. An incomplete affected draft prevents that unit change and stays editable. US liquid gallons and Imperial gallons have different volumes and are labeled separately. The litre is exactly 0.001 m³; the international foot is exactly 0.3048 m. Exact conversion factors do not make measured dimensions or numerical cylinder volumes exact.
How are very small contents, near-full levels and input limits handled?
Used inside dimensions range from 0.001 to 1,000 m. Depth must be between empty and full; volume and percentage cannot exceed capacity. Authored numbers allow 16 significant digits and 12 effective decimal places, with a 160-character limit. A depth band may be 0–1,000 m, and an oversized band is explicitly clipped. The model retains small liquid and empty quantities separately instead of losing them through subtraction of rounded totals. A cylinder's capacity contains π, so pasting a rounded capacity as a volume is not an exact full-tank instruction; use full depth or 100% for that endpoint. Unsupported numerical precision and unresolved close comparisons are reported explicitly.
Similar Calculators
Pool Salt Calculator
Estimate pool salt mass from measured and target salinity, water volume and purity. Compare the amount to add with whole bags to buy and measurement scenarios.
Concrete Slab Calculator
Estimate concrete slab volume, cubic yards, bag count, waste allowance, and material cost.
Pump Flow per Hour Calculator
Pump Flow per Hour for the exact fields in this tool, with clear inputs and an immediate result for planning or comparison.
Propane Usage & Supply Planner
Estimate propane usage across appliances and changing daily routines. Compare fuel demand, reserve timing, supply shortfalls and replacement costs with exact ledgers.
Cone & Frustum Capacity Calculator
Compare cone, frustum and cylinder capacity, liquid depth and surface areas. Inspect fill curves, solve target-volume depth and explore ideal sector or rectangle development.
