Water Well Volume, Storage & Drawdown Calculator

Compare two sets of bore and water-level measurements. Enter one to three sections with measured inside diameters, the water level before pumping, a recorded pumping level and the depth of the intake. The profiles show where water was released and how much remains above or below the intake. Add measured total discharge to reconcile a recorded drawdown interval.

Well measurements

Compare water well storage and drawdown

See how measured bore sizes and water depths change the water held, the volume above an intake, and the balance of a recorded discharge trial.

Compare well storage

Well A

36.72 US gal

Above the intake at the observed level

Above intake by 25 ft

Static water held
139.54 US gal
Observed water held
73.44 US gal
Observed drawdown
45 ft
Storage released
66.10 US gal

Well B

73.44 US gal

Above the intake at the observed level

Above intake by 50 ft

Static water held
225.22 US gal
Observed water held
124.85 US gal
Observed drawdown
45 ft
Storage released
100.37 US gal

Well B minus Well A above intake +36.72 US gal

Edit well measurements

Use the same top reference for all depths in a well. Each cylindrical section starts where the previous one ends.

Section 1

Use total discharge over the recorded interval from the static reading to the observed pumping reading.

Well depth and water profile

Profiles share a depth scale. Bore widths use their own scale so changes in inside diameter remain visible.

  • Drawdown band
  • Observed water above intake
  • Observed water below intake
  • Intake mark
Well A
Well A bore and water levelsDepths measured down from the same reference. Static water 30 ft, observed water 75 ft, intake 100 ft, measured bottom 125 ft. Above intake at the observed level.037.575112.5150ft
Static depth
30 ft
Observed depth
75 ft
Intake depth
100 ft
Well bottom
125 ft
Well B
Well B bore and water levelsDepths measured down from the same reference. Static water 20 ft, observed water 65 ft, intake 115 ft, measured bottom 150 ft. Above intake at the observed level.037.575112.5150ft
Static depth
20 ft
Observed depth
65 ft
Intake depth
115 ft
Well bottom
150 ft

Measured trial balance

Discharged water minus storage released gives the estimated net water entering the bore over the recorded interval.

Well A

120.00 US gal discharged − 66.10 US gal released

53.90 US gal estimated net entry

3.59 US gal/min mean net entry during 15 min

Well B

135.00 US gal discharged − 100.37 US gal released

34.63 US gal estimated net entry

2.31 US gal/min mean net entry during 15 min

Show section volume ledger
Well A
Section depthInside diameterStatic heldObserved heldObserved above intakeReleased
0–125 ft6 in139.54 US gal73.44 US gal36.72 US gal66.10 US gal
Well B
Section depthInside diameterStatic heldObserved heldObserved above intakeReleased
0–50 ft8 in78.34 US gal0.00 US gal0.00 US gal78.34 US gal
50–150 ft6 in146.88 US gal124.85 US gal73.44 US gal22.03 US gal

Export the well comparison

Save every depth section, modeled water volume and measured trial balance.

Download well storage CSV
Show selectable CSV

How to use this calculator

  1. Choose Uniform vs stepped bore or At and below intake. Select Well A or Well B to edit its independent depth record.
  2. Enter Static water depth, Observed pumping depth and Pump intake mark from the same reference. Enter the bottom of each measured section and its inside diameter.
  3. For an existing measured trial, enable Include measured discharge. Enter its actual discharged gallons and the elapsed minutes for the two water readings.
  4. Compare the profiles and gallons above the intake. Open Show section volume ledger to trace each section’s contribution.
  5. Download well storage CSV to save both geometry records, levels, modeled gallons and any trial balance.

The Formula

The mathematical logic powering this calculation is:

Measure every depth down from a common reference within each well. Section 1 starts at 0 ft. Each next section starts at the preceding end depth, and the last end is the measured well bottom. A circular section of diameter d inches contains πd² × 12/(4 × 231) US gallons per foot of water column. This uses exactly 12 inches per foot and 231 cubic inches per US gallon.
For each section, volume in a depth band equals its gallons per foot times the positive overlap between the section and the depth band. Sum across all sections. Static water held uses the static water line to the well bottom. Observed water held uses the pumping water line to the bottom. Above-intake water uses the water line to the intake, or zero when the line reaches or passes it. Water below intake is total held minus above-intake volume. Intake clearance equals intake depth minus water depth, with positive meaning the water line is shallower than the intake. These volumes describe the space inside the measured bore.
Drawdown = observed pumping depth minus static depth. Storage released is the volume of the band between those two depths. With a measured trial, estimated net water entering the bore equals measured total discharge minus modeled storage released during that interval. Average discharge and average net entry each divide their respective volumes by the entered elapsed minutes. A negative result is retained and flagged as a mismatch with the storage estimate for the recorded interval. The average describes the submitted observation window. Water delivery over longer periods depends on site conditions and well testing.
Use 1–3 cylindrical sections per well, starting at 0 ft and ending at increasing depths through 20,000 ft. Inside diameters are 1–48 in. Static and observed levels may be at 0 ft or at the bottom. The observed level must be as deep as or deeper than static. The intake is a positive depth at or above the bottom. Optional discharge totals are 0–10,000,000 US gal and elapsed times are 0.0001–1,000,000 min. Entries allow up to four decimal places. Values are modeled in US gallons and feet, with display rounding only.
The piecewise cylinders use unoccupied internal dimensions. They omit irregular openings, sediment, equipment displacement and exterior formations. This worksheet covers geometric storage and already recorded measurements. It excludes pump selection, intake-setting advice, aquifer or recovery prediction, safe well capacity, and water quality.

Worked Example

If you input:

  • Well A: 6 in inside diameter through 125 ft. Static 30 ft, observed 75 ft, intake 100 ft. 120 US gal discharged over 15 min.
  • Well B: 8 in inside diameter through 50 ft then 6 in through 150 ft. Static 20 ft, observed 65 ft, intake 115 ft. 135 US gal discharged over 15 min.

Result:

Both observed levels are 45 ft deeper than static. Well A releases 66.10 US gal from storage and retains 36.72 US gal above its intake. Well B releases 100.37 US gal and retains 73.44 US gal above its intake. The measured discharge balances imply 53.90 and 34.63 US gal of net water entry over the respective recorded intervals.

Frequently Asked Questions

How much water is in a 6-inch well?

A circular bore with a 6-inch inside diameter holds about 1.47 US gallons per foot of standing water. A uniform 100-foot water column holds about 146.88 US gallons.

Why can a well hold water below the intake?

The bore can extend below the intake. If the water line is at or below the intake, the volume above it is zero. The measured depth profile can still show water in the lower part of the bore.

How do I enter a well that changes diameter?

Give each cylindrical section its own end depth and inside diameter. Its start depth is the previous section’s end. The model sums the parts of those cylinders that overlap each water band.

What does estimated net entry mean?

It is the measured discharge minus the portion explained by stored water released between the two levels. It reconciles the measured interval. A negative residual flags a mismatch between those readings and the geometry.

Are two wells with the same drawdown losing the same amount of water?

The same depth change can release different water volumes because volume per foot depends on inside diameter squared. Compare the drawn bands and inspect section-by-section release in the ledger.

Which depth should I use as the starting reference?

Use the common reference shown in the measurement record for that well. Give all section ends, water levels and the intake depth relative to that same point.

Similar Calculators