Water Well Volume, Storage & Drawdown Calculator
Compare two sets of bore and water-level measurements. Enter one to three sections with measured inside diameters, the water level before pumping, a recorded pumping level and the depth of the intake. The profiles show where water was released and how much remains above or below the intake. Add measured total discharge to reconcile a recorded drawdown interval.
Compare water well storage and drawdown
See how measured bore sizes and water depths change the water held, the volume above an intake, and the balance of a recorded discharge trial.
Compare well storage
Well A
36.72 US gal
Above the intake at the observed level
Above intake by 25 ft
- Static water held
- 139.54 US gal
- Observed water held
- 73.44 US gal
- Observed drawdown
- 45 ft
- Storage released
- 66.10 US gal
Well B
73.44 US gal
Above the intake at the observed level
Above intake by 50 ft
- Static water held
- 225.22 US gal
- Observed water held
- 124.85 US gal
- Observed drawdown
- 45 ft
- Storage released
- 100.37 US gal
Well B minus Well A above intake +36.72 US gal
Edit well measurements
Use the same top reference for all depths in a well. Each cylindrical section starts where the previous one ends.
Use total discharge over the recorded interval from the static reading to the observed pumping reading.
Well depth and water profile
Profiles share a depth scale. Bore widths use their own scale so changes in inside diameter remain visible.
- Drawdown band
- Observed water above intake
- Observed water below intake
- Intake mark
- Static depth
- 30 ft
- Observed depth
- 75 ft
- Intake depth
- 100 ft
- Well bottom
- 125 ft
- Static depth
- 20 ft
- Observed depth
- 65 ft
- Intake depth
- 115 ft
- Well bottom
- 150 ft
Measured trial balance
Discharged water minus storage released gives the estimated net water entering the bore over the recorded interval.
Well A
120.00 US gal discharged − 66.10 US gal released
53.90 US gal estimated net entry
3.59 US gal/min mean net entry during 15 min
Well B
135.00 US gal discharged − 100.37 US gal released
34.63 US gal estimated net entry
2.31 US gal/min mean net entry during 15 min
Show section volume ledger
| Section depth | Inside diameter | Static held | Observed held | Observed above intake | Released |
|---|---|---|---|---|---|
| 0–125 ft | 6 in | 139.54 US gal | 73.44 US gal | 36.72 US gal | 66.10 US gal |
| Section depth | Inside diameter | Static held | Observed held | Observed above intake | Released |
|---|---|---|---|---|---|
| 0–50 ft | 8 in | 78.34 US gal | 0.00 US gal | 0.00 US gal | 78.34 US gal |
| 50–150 ft | 6 in | 146.88 US gal | 124.85 US gal | 73.44 US gal | 22.03 US gal |
Export the well comparison
Save every depth section, modeled water volume and measured trial balance.
Download well storage CSVShow selectable CSV
How to use this calculator
- Choose Uniform vs stepped bore or At and below intake. Select Well A or Well B to edit its independent depth record.
- Enter Static water depth, Observed pumping depth and Pump intake mark from the same reference. Enter the bottom of each measured section and its inside diameter.
- For an existing measured trial, enable Include measured discharge. Enter its actual discharged gallons and the elapsed minutes for the two water readings.
- Compare the profiles and gallons above the intake. Open Show section volume ledger to trace each section’s contribution.
- Download well storage CSV to save both geometry records, levels, modeled gallons and any trial balance.
The Formula
The mathematical logic powering this calculation is:
Measure every depth down from a common reference within each well. Section 1 starts at 0 ft. Each next section starts at the preceding end depth, and the last end is the measured well bottom. A circular section of diameter d inches contains πd² × 12/(4 × 231) US gallons per foot of water column. This uses exactly 12 inches per foot and 231 cubic inches per US gallon.
For each section, volume in a depth band equals its gallons per foot times the positive overlap between the section and the depth band. Sum across all sections. Static water held uses the static water line to the well bottom. Observed water held uses the pumping water line to the bottom. Above-intake water uses the water line to the intake, or zero when the line reaches or passes it. Water below intake is total held minus above-intake volume. Intake clearance equals intake depth minus water depth, with positive meaning the water line is shallower than the intake. These volumes describe the space inside the measured bore.
Drawdown = observed pumping depth minus static depth. Storage released is the volume of the band between those two depths. With a measured trial, estimated net water entering the bore equals measured total discharge minus modeled storage released during that interval. Average discharge and average net entry each divide their respective volumes by the entered elapsed minutes. A negative result is retained and flagged as a mismatch with the storage estimate for the recorded interval. The average describes the submitted observation window. Water delivery over longer periods depends on site conditions and well testing.
Use 1–3 cylindrical sections per well, starting at 0 ft and ending at increasing depths through 20,000 ft. Inside diameters are 1–48 in. Static and observed levels may be at 0 ft or at the bottom. The observed level must be as deep as or deeper than static. The intake is a positive depth at or above the bottom. Optional discharge totals are 0–10,000,000 US gal and elapsed times are 0.0001–1,000,000 min. Entries allow up to four decimal places. Values are modeled in US gallons and feet, with display rounding only.
The piecewise cylinders use unoccupied internal dimensions. They omit irregular openings, sediment, equipment displacement and exterior formations. This worksheet covers geometric storage and already recorded measurements. It excludes pump selection, intake-setting advice, aquifer or recovery prediction, safe well capacity, and water quality.Method sources
- Missouri DNR · inside diameter and static groundwater column volume
- Wisconsin DNR · approximate standing water storage by foot
- USGS Water Science School · water levels and the intake
- FERC-hosted water supply monitoring plan, Appendix L · observed discharge and storage balance
- NIST Handbook 133 Appendix E · customary volume conversions
Worked Example
If you input:
- Well A: 6 in inside diameter through 125 ft. Static 30 ft, observed 75 ft, intake 100 ft. 120 US gal discharged over 15 min.
- Well B: 8 in inside diameter through 50 ft then 6 in through 150 ft. Static 20 ft, observed 65 ft, intake 115 ft. 135 US gal discharged over 15 min.
Result:
Both observed levels are 45 ft deeper than static. Well A releases 66.10 US gal from storage and retains 36.72 US gal above its intake. Well B releases 100.37 US gal and retains 73.44 US gal above its intake. The measured discharge balances imply 53.90 and 34.63 US gal of net water entry over the respective recorded intervals.
Frequently Asked Questions
How much water is in a 6-inch well?
A circular bore with a 6-inch inside diameter holds about 1.47 US gallons per foot of standing water. A uniform 100-foot water column holds about 146.88 US gallons.
Why can a well hold water below the intake?
The bore can extend below the intake. If the water line is at or below the intake, the volume above it is zero. The measured depth profile can still show water in the lower part of the bore.
How do I enter a well that changes diameter?
Give each cylindrical section its own end depth and inside diameter. Its start depth is the previous section’s end. The model sums the parts of those cylinders that overlap each water band.
What does estimated net entry mean?
It is the measured discharge minus the portion explained by stored water released between the two levels. It reconciles the measured interval. A negative residual flags a mismatch between those readings and the geometry.
Are two wells with the same drawdown losing the same amount of water?
The same depth change can release different water volumes because volume per foot depends on inside diameter squared. Compare the drawn bands and inspect section-by-section release in the ledger.
Which depth should I use as the starting reference?
Use the common reference shown in the measurement record for that well. Give all section ends, water levels and the intake depth relative to that same point.
Similar Calculators
Pipe Volume, Fill & Flush Calculator
Calculate multi-section pipe liquid volume in litres, US gallons or cubic metres. Include equipment, estimate filling time and compare displacement with complete-mixing replacement.
Pump Curve & Operating Point Planner
Compare pump curves and speeds against system head. Visualize operating flow, runtime, electrical energy and whether your target volume fits the available hours.
Tank Volume & Dip Chart Calculator
Find tank volume from liquid depth or solve depth from volume. Compare fill levels and export dip charts for horizontal cylinders, upright cylinders and boxes.