Volumetric Flow Rate & Collection Audit Calculator

Compare up to eight recorded liquid-flow runs. Use a measured volume or net mass and documented density. Get each run’s flow range, calculate an average across all sampled time, compare paired meter indications and estimate time for a target volume.

Timed liquid collections

Compare flow across measured collections

Use collected volume or net mass and elapsed time to trace individual runs and the combined flow.

Pooled measured flow
14.832960038 L/min
25.216032064 L in 102 s
Target duration
6.741742696 min
100 L target
Edit collections and target

The target is optional. Enter net mass without the container and pair each meter reading with the same collection time.

Timed jug · Measured volume
Timed scale · Net mass
Longer jug · Measured volume

Flow by collection

Select a collection to trace the volume, time and optional meter comparison.

Measured boundsStated ratePooled rateMeter indication

14.702970297 L/min to 15.303030303 L/min

14.787338652 L/min to 15.275834688 L/min

14.433399602 L/min to 14.849094567 L/min

14.3551 L/min15.3813 L/min

Pooled volume and time

Target duration

Measured pooled flow range
14.597393424 L/min to 15.071782261 L/min
Total collected
24.985871743 L to 25.446192385 L
Total time
101.3 s to 102.7 s
Target volume
100 L
Fastest modeled
6.634915385 min
At stated flow
6.741742696 min
Slowest modeled
6.850538113 min

This estimate assumes the pooled rate continues.

Paired meter comparison

Matched collections
2 of 3
Collected across pairs
12.885871743 L to 13.146192385 L
Meter volume across pairs
12.973 L to 13.173666667 L
Collected / indicated factor
0.995616935
Factor range
0.978153772 to 1.013350219

The factor compares collected volume with indicated volume over the matched run times.

Selected collection

Timed scale

Recorded collection

Input basis
Entered bounds
Net mass
7.92 kg to 8.08 kg
Elapsed time
31.8 s to 32.2 s
Entered density
0.998 kg/L
Volume used
7.935871743 L to 8.096192385 L
Stated rate
15.03006012 L/min
Flow range
14.787338652 L/min to 15.275834688 L/min

Meter on this run

Indicated rate
15.2 L/min
Measured minus indicated
-0.412661348 L/min to +0.075834688 L/min
Indicated volume
8.056 L to 8.157333333 L
Collected / indicated factor
0.972851227 to 1.004989124
Download collection audit CSV
Show selectable CSV

How to use this calculator

  1. Enter the volume units, an optional target and a density if any observations use net mass.
  2. Record each collection amount and duration. Choose Entered bounds for measurements with an amount and timing allowance.
  3. Enter an average meter indication only for the window represented by that run.
  4. Compare run and pooled flow, then select a run to trace its measurements and indicated difference.
  5. Download your input basis, rate bounds, combined meter comparison and estimated target duration.

The Formula

The mathematical logic powering this calculation is:

Volumetric flow is delivered volume divided by elapsed time. Enter the volume measured across your collection or the net liquid mass with a documented density. Net mass is liquid alone after accounting for the container. For a mass run, volume in liters equals mass in kilograms divided by density in kilograms per liter. The worksheet uses the same entered density for all mass runs. Based on an elapsed time t in seconds, flow in liters per minute is 60 × V ÷ t.

Choose Stated values to compute the entered amount and time exactly as recorded. Choose Entered bounds to provide a nonnegative amount allowance and a nonnegative time allowance. Amount ranges are clipped at zero on the lower side. The lowest time must remain strictly positive. The lowest flow uses the lowest amount with the longest time. The highest flow uses the greatest amount with the shortest time. These arithmetic bounds use your supplied values and fixed density. They carry no statistical coverage level.

Pool collections by dividing total volume by total time. This weights each run by its elapsed time and describes the combined observed intervals. Adding runs from a different operating condition changes this mixed-sample average. For the exact pooled lower bound, sum the smallest volumes and divide by the sum of the longest times. For the upper bound, sum the largest volumes and divide by the sum of shortest times.

An optional average meter indication refers to that collection window. Per-run difference is measured flow minus the entered indication. The collected-to-indicated factor is defined for a positive indication. The paired factor across runs divides the summed collected volume for recorded pairs by the sum of indicated rate times elapsed time on those same pairs. Blank meter values leave their rows out. Zero indications remain part of the paired totals. A zero total indicated volume leaves the multiplier unavailable. These comparisons use recorded indications as fixed and are specific to the entered runs.

If you enter a target volume, divide it by the pooled rate to estimate how long it would take if that rate continues. The fastest duration uses the upper flow. The slowest uses the lower flow. If the lower flow is zero and the upper is positive, the range has no finite upper duration. If even the upper flow is zero, a positive target cannot be reached at those rates. A zero target takes no modeled time.

Use one to eight collections and elapsed times from 0.001 to 1,000,000 seconds. Volume and target inputs accept zero to 10,000,000 L equivalent. Net mass accepts zero to 20,000,000 kg. Density accepts 0.001 to 20 kg/L. An entered meter indication may be zero through 1,000,000,000 L/min equivalent. These are worksheet limits. Values accept up to twelve decimal places or exact fractions. One U.S. gallon is exactly 231 cubic inches or 3.785411784 L. Unit changes preserve recorded amounts and rates. The export gives exact values in liters, seconds and liters per minute.

This worksheet compares recorded collections. A calibrated meter result also depends on method, instrument uncertainty, liquid conditions and repeatability. Use compatible observations and the appropriate density for your liquid.

Worked Example

If you input:

  • Collection runs: 5 L in 20 s, 8 kg in 32 s and 12.2 L in 50 s
  • Density: 0.998 kg/L for the net mass run
  • Amount and time allowances: ±0.05 L, ±0.08 kg and ±0.1 L. Time ±0.2 s, ±0.2 s and ±0.3 s.
  • Paired meter indications: 14.9 L/min, 15.2 L/min and blank
  • Target volume: 100 L

Result:

The combined sampled flow is 14.832960038 L/min, bounded by 14.597393424 to 15.071782261 L/min. The modeled time for 100 L at the stated rate is 6.741742696 min. The meter comparison has two paired observations and retains the third collection in the overall pooled flow.

Frequently Asked Questions

How do I calculate volumetric flow from a timed collection?

Divide collected volume by elapsed time. Multiply by 60 to express liters per minute when the amount is in liters and the elapsed time is in seconds.

Can I calculate volumetric flow from mass and time?

Yes. Divide the net liquid mass by the applicable density to get volume, then divide by elapsed time. The worksheet requires you to enter the density.

Why does the pooled flow differ from an average of the rows?

Longer runs contribute more observed time. Pooled flow divides all collected volume by all elapsed time, which weights each row by its duration.

When does a target have no finite upper duration?

A positive target has no finite slower-time bound if the supplied flow interval includes zero. If the whole interval is zero, the target cannot be reached at the observed rates.

What happens when a meter only has readings for some runs?

The paired factor uses collected and indicated volume over matching windows. Unpaired collections still contribute to overall measured flow.

Similar Calculators