Measured Pump Head Calculator & Tap Audit

Compare two recorded pump tests using suction and discharge gauge pressure, elevation and pipe inside diameter. Separate the signed pressure, elevation and velocity terms. See the head change between the two stations, plus a separately labeled estimate if you enter documented loss coefficients between the stations and the pump.

Recorded pump tests

Reconcile pump head from two measurement stations

Pump head results

Test A · DOE reference

275.52 ft tap-to-tap

276.81 ft adjusted

Mean speed 5.67 ft/s suction and 8.17 ft/s discharge

Test B · Equal-diameter example

221.53 ft tap-to-tap

Measured terms only

Mean speed 4.54 ft/s suction and 4.54 ft/s discharge

Test A tap-to-tap head 275.52 ft. Test B tap-to-tap head 221.53 ft

Recorded test inputs

Readings stay physically unchanged when you switch units. Converted fields can show exact fractions. For each test, use a gauge pressure reference and elevation datum common to both stations.

Trial conditions
Suction station
Discharge station

Enter only the documented losses between each measured station and its pump connection. The model references each dimensionless K to that station’s velocity.

Head contributions and losses

Signed head contributions

The zero marker divides energy gains to the right and decreases to the left.

  • Test A
  • Test B

Pressure head

A · 274.99 ftB · 219.53 ft

Elevation head

A · 0.00 ftB · 2.00 ft

Velocity head

A · 0.54 ftB · 0.00 ft

Tap-to-tap head

A · 275.52 ftB · 221.53 ft

Adjusted head

A · 276.81 ftB · Unavailable
0.00 ft276.81 ft
Velocity and correction detail

A separate scale makes the velocity term and entered loss corrections easier to compare.

  • Test A
  • Test B

Velocity head

A · 0.54 ftB · 0.00 ft

Suction correction

A · 0.25 ftB · Unavailable

Discharge correction

A · 1.04 ftB · Unavailable
0.00 ft1.04 ft

Pump head worksheet

Pressure, elevation and velocity head, totals and supplied corrections
Head termsTest A (ft)Test B (ft)
Pressure head274.99 ft219.53 ft
Elevation head0.00 ft2.00 ft
Velocity head0.54 ft0.00 ft
Tap-to-tap head275.52 ft221.53 ft
Suction correction0.25 ftUnavailable
Discharge correction1.04 ftUnavailable
Adjusted head276.81 ftUnavailable
Download pump head CSV
Open selectable pump head CSV

How to use this calculator

  1. Choose a recorded test and its entry units. Keep the input pressure reference and elevation datum consistent within that test.
  2. Enter liquid density and measured through-flow, plus the gauge pressure, elevation and actual inside diameter at each station.
  3. If applicable, enable documented loss coefficients and enter the suction and discharge values referred to the respective measurement station.
  4. Compare pressure, elevation and velocity terms, then compare the tap-to-tap head with any adjusted estimate.
  5. Download both measured tests, the recorded values and derived terms in meters and feet.

The Formula

The mathematical logic powering this calculation is:

For steady incompressible liquid flow through two circular sections in series, mean velocity v = 4Q/(πD²) using the measured common flow Q and the actual local inside diameter D. Use gauge pressures for both stations relative to the same reference and elevations from the same datum. Each recorded pressure and its paired elevation must refer to the same measurement location. Apply any necessary instrument elevation adjustment in the recorded input before entering it.

The change from suction to discharge is the sum of three signed terms: pressure head (p_d − p_s)/(ρg), elevation head z_d − z_s, and velocity head (v_d² − v_s²)/(2g). The measured tap-to-tap result keeps the kinetic energy coefficient at one and uses g = 9.80665 m/s². A negative total or component remains negative. At zero flow, the two speeds and velocity contributions are zero, while valid static terms remain available.

If you enable the optional corrections with documented K values, estimate each tap-to-pump loss as K × v²/(2g), with K referenced to that measurement station's section velocity. Add both losses to the measured tap-to-tap head and label the result adjusted. The measured result stays separate and remains usable if an enabled coefficient is missing. The program does not infer these values from pipe geometry alone.

Enter pressure and elevation in kPa gauge and meters, or psi gauge and feet. Inside diameter uses millimeters or inches. Through-flow uses m³/h or U.S. gallons per minute, with density in kg/m³ in both modes. International ft equals 0.3048 m and in equals 0.0254 m. A U.S. gallon equals 231 cubic inches. The psi conversion uses 0.45359237 kg per pound and standard gravity. The exact entry switch can express a non-terminating decimal as a fraction. Use up to six decimal places or an exact fraction with a positive denominator.

Canonical bounds are pressures within ±100 MPa, elevations within ±10,000 m, diameters 0.001–100 m, through-flow 0–1,000 m³/s, density 100–2,000 kg/m³, and K 0–1,000. These are numeric bounds. Exact rational arithmetic preserves same-diameter and zero-flow cancellation and carries π to about 60 significant decimal digits before numeric output. Head is displayed to 2 decimal places in ft or 6 in m, with scientific notation for a nonzero value that would display as zero.

The calculation compares already recorded observations. It gives no operating limits, installation or test procedure, pressure rating, equipment selection, efficiency, cavitation or NPSH assessment. The corrected result is an estimate based on the loss terms you supplied.

Worked Example

If you input:

  • DOE reference trial, Test A: 2,000 US gpm. Suction 5 psi gauge, 5 ft and 12 in ID. Discharge 124 psi gauge, 5 ft and 10 in ID. Entered density 998.2 kg/m³ and K values 0.5, 1.
  • Equal-diameter illustration, Test B: 1,600 US gpm at the same density. Suction 5 psi gauge and 5 ft. Discharge 100 psi gauge and 7 ft. Both IDs 12 in. Adjustments disabled.

Result:

Test A gives 274.99 ft pressure head, 0.00 ft elevation head and 0.54 ft velocity head, yielding 275.52 ft tap-to-tap. Its estimated K corrections are 0.25 ft and 1.04 ft, giving 276.81 ft adjusted. The entered density reproduces the rounded DOE example. Test B gives 221.53 ft measured tap-to-tap and no velocity difference.

Frequently Asked Questions

Does a pump's pressure difference equal its total head?

The static pressure difference is one component. Unequal measurement elevations add an elevation term and different mean speeds add a velocity term.

Why can the velocity term be negative?

At the same through-flow a wider discharge section has a lower mean speed. The calculation subtracts the suction velocity head from the discharge velocity head.

Which elevations should I enter?

Use a common elevation datum, with each number referring to where its entered pressure is defined. If pressure was corrected to the tap elevation, pair it with that tap elevation.

Why add the entered losses to get the adjusted estimate?

For the sketched suction-to-discharge passage, losses between the measurement stations and the corresponding pump connections reduce the observed energy rise. The supplied correction restores those modeled losses to the adjusted head.

Does changing units affect the comparison?

A valid entry-unit change preserves the physical inputs, sometimes as exact fractions. The separate result switch changes only the display in meters or feet.

Can I treat the adjusted result as a pump selection recommendation?

The estimate describes the submitted steady measurements and documented corrections. It does not establish a performance curve, operating limit or suitable equipment.