Grease Trap & Interceptor Peak Flow Calculator
Record separate kitchen discharge volumes, start times and durations. See where their mean flows overlap and which measured interval creates the peak demand. Compare two documented interceptor flow caps and quote prices for that entered timeline, with exact time and volume above each cap.
Compare measured grease interceptor discharge peaks
Check when recorded discharges overlap and which entered flow cap covers the resulting peak.
Edit measured discharge events
Edit documented caps and prices
Modeled peak
36 GPM
20 s at peak · 22 US gal total
First peak 10 to 30 s
Offer A · 36 GPM
$400.00
Covers the peak
0 s above cap · 0 US gal above cap
Offer B · 48 GPM
$575.00
Covers the peak
0 s above cap · 0 US gal above cap
Inspect discharge timing and coincident flow
Combined flow (GPM)
- Combined flow
- Offer A cap
- Offer B cap
Interval 2 · 10 to 30 s
36 GPM · 20 s at peak
12 US gal in this interval
- Discharge 1 · 24 GPM
- Discharge 3 · 12 GPM
Review exact flow intervals and export
| Interval | Start (s) | End (s) | Active discharges | Flow (GPM) | Volume (US gal) |
|---|---|---|---|---|---|
| 1 | 0 | 10 | 1 | 24 | 4 |
| 2 · Peak | 10 | 30 | 1, 3 | 36 | 12 |
| 3 | 30 | 60 | 2 | 12 | 6 |
The ledger shows fractions when a rounded decimal would lose precision.
How to use this calculator
- Copy the observed volume, start time and duration for each discharge using the same clock and captured-volume basis.
- Enter each written flow cap and same-scope quote price.
- Read the peak amount, overlap duration, and time and arithmetic volume above each cap.
- Move the interval control or jump to the first peak to see exactly which recorded sources contribute.
- Export the discharge and interval ledger.
The Formula
The mathematical logic powering this calculation is:
Use the measured US gallons and elapsed seconds of each discharge on a common clock. Modeled flow during that interval is its volume divided by duration and multiplied by 60 for gallons per minute. This constant interval flow is an average assumption for each entered discharge.
Sort and deduplicate event starts and ends, including time zero. Every event contributes over the half-open interval from its start through just before its end. At exactly the same timestamp, an ending discharge is gone when a starting discharge begins. Sum rates on the intervals between consecutive endpoints. The largest sum is the modeled peak. Join adjacent positive peak intervals even if their active discharge identities differ. The chart preserves the other active-set changes.
A documented cap covers the modeled peak when it is greater than or equal to that peak. Headroom equals cap minus peak. For each interval above the cap, add its duration to the excess time and its excess rate times its duration divided by 60 to the arithmetic excess gallons. This is the area above the cap line, separate from captured grease, stored liquid or overflow volume. Compare quote prices only among modeled flow matches. Quotes use the same included scope.
Enter 2–8 discharges, 0–86,400 s start, 0.001–3,600 s duration and 0–1,000 US gal. Flow caps accept 0–1,000,000 GPM. Times, volumes and rates accept up to three decimal places, while quote amounts accept 0–1,000,000 USD to cents. Comparisons, accumulation and CSV use exact reduced fractions.
This worksheet compares documented caps with measured scenario averages. Actual transient peaks, transport lag, fixture connection requirements, uncertain event times, grease retention, flow-control behavior and approval are separate evaluations. It does not determine the legally required interceptor size or service interval.Worked Example
If you input:
- Discharge 1: 12 US gal starting at 0 s for 30 s
- Discharge 2: 6 US gal starting at 30 s for 30 s
- Discharge 3: 4 US gal starting at 10 s for 20 s
- Offers: 36 GPM at $400 and 48 GPM at $575. These are illustrative quoted caps.
Result:
The modeled peak is 36 GPM from 10 s through just before 30 s. Both caps cover it and Offer A costs less. Moving Discharge 2 earlier by 0.001 s creates a 48 GPM peak for 0.001 s. Flow above Offer A’s cap integrates to 0.0002 US gal, and only Offer B matches the full peak.
Frequently Asked Questions
Why does one event ending as another starts produce no overlap?
The model includes the start and excludes the end of each event. This avoids double counting at a shared timestamp and does not add a zero-length interval.
What does the amount above a cap measure?
It is the integral of modeled flow minus the cap during intervals where flow is higher. It quantifies the comparison without predicting how an actual vessel stores or releases that water.
Are grease capacity and rated flow the same?
Product specifications list hydraulic flow and grease capacity separately. This worksheet uses only the hydraulic cap and the discharge log.
Can a recorded discharge contain a short spike above its average rate?
The model treats each recorded interval as constant flow, so a transient peak can be higher than its interval average. Use separate measured subintervals to capture a changing rate when those data are available.
Similar Calculators
Volumetric Flow Rate & Collection Audit Calculator
Calculate liquid flow from timed volume or mass collections. Compare measured bounds, duration-weighted flow, meter readings and target fill time.
Drain Pipe Slope & Invert Reconciliation Calculator
Audit measured plumbing drain pitch and cover, then find whether a straight grade from a fixed outlet fits every entered limit.
Septic Tank Size & Capacity Calculator
Compare residential septic tank liquid capacities, compartment requirements and design flow under Minnesota rules or a locally confirmed minimum.