Thévenin Equivalent Calculator & Load Audit

Replace an ideal-source DC resistor network with its Thévenin equivalent at terminals A and B. Compare two separately connected loads, see how each shifts both terminal voltages, and find the minimum finite input resistance for your allowed loss of open-circuit voltage.

Ideal DC resistive network

Find the equivalent and compare two loads

Neither load meets the voltage-loss limit.

Open-circuit voltage
5 V
Equivalent resistance
1,500 Ω
Power at matched load
4.166667 mW
Minimum resistance for entered limit
148,500 Ω

Circuit and load inputs

Network and output terminals

Output is A minus B. The open-circuit node voltages are 7.5 V at A and 2.5 V at B. The load bridges the two divider midpoints.

Voltage and power across load sizes

Solid blue tracks retained voltage. Dashed green tracks delivered power. The logarithmic scale compares load resistance with the equivalent source resistance.

Load A at 1,500 Ω delivers 2.5 V and 4.166667 mW. Shares use the open-circuit voltage magnitude and theoretical peak power.

Loaded terminal audit
QuantityLoad ALoad B
Terminal A6.25 V7.463054 V
Terminal B3.75 V2.536946 V
A − B voltage2.5 V4.926108 V
A to B current1.666667 mA0.04926108 mA
Load power4.166667 mW0.2426654 mW
Voltage loss50 %1.477833 %
Entered limitAbove limitAbove limit

Exact equivalent voltage 5 V and resistance 1500 Ω. The theoretical short current is 3.333333 mA from A to B. It is a mathematical reference.

Copyable load data

How to use this calculator

  1. Choose a voltage divider or a four-resistor bridge.
  2. Enter the signed ideal supply voltage and label each resistor by its position in the diagram.
  3. Enter two hypothetical load resistances. The calculator connects them separately between A and B.
  4. Enter the maximum loss of open-circuit voltage and compare the load marks on the power and voltage graph.
  5. Use the terminal ledger to check the two node voltages or download the exact fractional results.

The Formula

The mathematical logic powering this calculation is:

At open circuit, V_A = V_S R₂/(R₁ + R₂). For a bridge, V_B = V_S R₄/(R₃ + R₄). For a two-resistor divider, B is the zero-volt reference. The signed equivalent voltage is V_Th = V_A − V_B.

With the ideal supply set to zero, its two rails become one node. Looking into A and B, the equivalent resistance of a bridge is (R₁ ∥ R₂) + (R₃ ∥ R₄), where X ∥ Y = XY/(X + Y). A divider has only the first term. Swapping the midpoint voltages flips V_Th. It leaves the equivalent resistance and delivered load power unchanged when the two sides exchange places.

For a positive finite load R_L, model current I = V_Th/(R_Th + R_L), signed output V_L = I R_L and delivered power P_L = I² R_L. The left node changes by −I(R₁ ∥ R₂). In a bridge, the right node changes by +I(R₃ ∥ R₄). The theoretical short-circuit current is V_Th/R_Th. The load R_L = R_Th gives the maximum power V_Th²/(4R_Th) for nonzero output.

At nonzero open-circuit output, the relative loss of output magnitude is R_Th/(R_Th + R_L). For a fractional loss limit t between zero and one, the inclusive minimum load is R_Th(1 − t)/t. Zero allowed loss requires an open circuit. At 100% allowed loss, every positive load meets the limit. A zero-output bridge or zero-volt supply has zero loaded power and no voltage deviation. Its relative voltage and power shares are undefined.

All inputs are finite decimals with up to six fractional digits. The allowed supply is −1,000 to +1,000 V. Resistances may range from 0.001 to 1,000,000,000 Ω. This ideal model uses an ideal voltage source with positive linear resistors at DC. Short current and matched power are mathematical values and do not account for ratings, heating or source current limits.

Worked Example

If you input:

  • Supply: 10 V
  • Left arm: 1,000 Ω then 3,000 Ω
  • Right arm: 3,000 Ω then 1,000 Ω
  • Load A and B: 1,500 Ω and 100,000 Ω
  • Maximum voltage loss: 1%

Result:

The open-circuit midpoints are 7.5 V and 2.5 V. The resulting equivalent is 5 V in series with 1,500 Ω. Load A receives 2.5 V and about 4.167 mW. The inclusive minimum for 1% loss is 148,500 Ω, so neither entered load meets the limit.

Frequently Asked Questions

Why does an instrument change the voltage it reads?

Its finite input resistance draws current. That current creates a voltage drop across the Thévenin resistance. Larger input resistance reduces the size of the drop for this ideal DC network.

Why do the bridge midpoint voltages both change?

The load transfers current from one midpoint to the other. Each midpoint responds through the equivalent parallel resistance of its two surrounding resistors.

When is a bridge balanced?

The open-circuit output is zero for any supply when the left and right resistor ratios match. Both terminals remain at the same potential under any positive load in this ideal model.

Does maximum power also preserve the measured voltage?

At matched load resistance the load receives half the open-circuit voltage magnitude. For small measurement error, the load resistance needs to be much larger.

Can the output voltage be negative?

Yes. The calculator uses A minus B and labels current from A toward B. A negative current means it flows in the opposite direction. Delivered power remains nonnegative.

Similar Calculators