Equivalent Resistance Calculator

Connect resistors between named nodes and see how the network divides voltage, current and power. Inspect each branch on the circuit diagram, compare entered resistor tolerances and export the complete calculation.

Circuit explorer

Trace the circuit. See where the power goes.

Voltage is terminal A minus terminal B. Negative values reverse polarity. This ideal DC source has no internal resistance or current limit.

Unit changes preserve quantities. Remove or reconnect branches before removing a referenced node. Open branches keep their entries.

Try an example

Enter 0 for an ideal wire. A positive value models a resistor.

0–50%. Applied only to included positive resistances; open branches and ideal wires ignore this entry.

3 of 24 branches. Up to 24 significant digits; decimal or scientific notation. Positive resistance: 1e−12–1e12 Ω. Source magnitude: 0 or 1e−12–1e6 V. No grouping commas or unit suffixes in values.

Paste branches from a spreadsheet

Six columns in this order: label, from, to, resistance, tolerancePercent, enabled. The exact header is optional; enabled must be true or false. Values use the current resistance unit. Select enough nodes before importing. Applying a valid list replaces all branches.

Equivalent resistance

220 Ω

Between A and B. Calculated from the entire connected network, including bridges.

Source current

≈ 0.054545455 A

Signed current delivered out of terminal A.

Source power

≈ 0.65454545 W

Power supplied to the ideal passive network.

Follow the connections

Only the named circles are junctions. Crossing lines do not connect.

Resistor network between A and B. Select a numbered branch to inspect it.123ABC

Numbered boxes identify branches; a rounded marker is an ideal wire, and a dashed path is open. Arrows follow nominal current; zero or unavailable currents have no arrow. Dark nodes are the source terminals. The drawing shows connectivity, not physical wire length.

Source: A relative to B. The branch selector and results table provide the same inspection by keyboard.

Inspect R1

A → C · resistor

Resistance
100 Ω
Voltage drop
≈ 5.4545455 V
Signed current
≈ 0.054545455 A
Nominal power
≈ 0.29752066 W

Voltage drop and current use A → C as the positive direction.

Equivalent resistance: 220 Ω. Complete export available.

Terminal bounds from resistor tolerances

Independent component limits at a fixed source voltage. These are not probability intervals or individual branch-power limits.

Equivalent resistance
209 Ω to 231 Ω
Signed source current
≈ 0.051948052 A to ≈ 0.057416268 A
Source power
≈ 0.62337662 W to ≈ 0.68899522 W

Each enabled positive resistor varies independently within its entered symmetric tolerance.

Equivalent resistance bounds use all-low and all-high resistances. Source bounds hold the signed ideal voltage fixed.

These are component-box bounds, not statistical confidence intervals or individual branch-power maxima.

Where nominal power is dissipated

Every branch uses the same scale. These are nominal operating values, not power-rating recommendations.

Scale maximum: ≈ 0.29752066 W.

≈ 0.29752066 W
R1: ≈ 0.29752066 W.
≈ 0.21421488 W
R2: ≈ 0.21421488 W.
≈ 0.14280992 W
R3: ≈ 0.14280992 W.

Network results and exact quantities

Node potentials are relative to the reference terminal. Signed branch values follow the entered From → To direction.

View branch results
Nominal branch results
BranchConnectionResistanceVoltage dropSigned currentPower

resistor

A → C100 Ω

Exact: 100 Ω

≈ 5.4545455 V

Exact: 60/11 V

≈ 0.054545455 A

Exact: 3/55 A

≈ 0.29752066 W

Exact: 36/121 W

resistor

C → B200 Ω

Exact: 200 Ω

≈ 6.5454545 V

Exact: 72/11 V

≈ 0.032727273 A

Exact: 9/275 A

≈ 0.21421488 W

Exact: 648/3025 W

resistor

C → B300 Ω

Exact: 300 Ω

≈ 6.5454545 V

Exact: 72/11 V

≈ 0.021818182 A

Exact: 6/275 A

≈ 0.14280992 W

Exact: 432/3025 W

View node potentials
Node potentials relative to B
NodeStateIdeal-wire groupPotentialExact potential
AreferencedA12 V12 V
BreferencedB0 V0 V
CreferencedC≈ 6.5454545 V72/11 V
View conservation checks

Total finite-resistor dissipation: ≈ 0.65454545 W

Source power minus resistor dissipation: 0 W

  • Current-law residual at group A: 0 A
  • Current-law residual at group B: 0 A
  • Current-law residual at group C: 0 A

A zero residual checks the ideal mathematical model. It does not validate component values, wiring or real-world safety.

Selectable CSV text

The selectable text and download use the same complete export, including raw entries, exact quantities, unavailable reasons and assumptions.

Method, assumptions and sources

The solver contracts ideal wires, excludes open branches and uses Kirchhoff’s current law to solve node potentials. Branch current is voltage drop divided by resistance; nominal power is current times voltage drop. A unit-voltage solution gives equivalent resistance even when the entered source is zero.

  • One ideal DC voltage source supplies passive linear resistors; the voltage is terminal A minus terminal B.
  • A positive branch current follows the entered from-to direction. Negative values mean the reverse direction.
  • Enabled zero resistance means an ideal wire; disabled branches are ideal opens. AC impedance, nonlinear devices and thermal limits are outside this model.
  • Exact rational values drive topology, signs, conservation and tolerance bounds; decimal displays are rounded only for presentation.
  • KCL checks sum finite-resistor outflow minus external source injection for each contracted ideal-wire group.

See OpenStax’s resistor-network relationships, UCF’s nodal-analysis explanation, and Yale’s effective-resistance and monotonicity notes. Tolerance bounds follow passive-network monotonicity under the entered independent resistance limits.

How to use this calculator

  1. Choose the number of nodes and two distinct source terminals, then enter the signed Source voltage. Select mV or V and mΩ, Ω, kΩ or MΩ; changing units preserves valid quantities instead of reinterpreting them.
  2. Add or select a branch, name its From and To nodes and enter its resistance. Enable zero resistance for an ideal wire, or disable a branch to make it open while retaining its draft. Node names define connectivity; a crossing on the drawing is not automatically a connection.
  3. Optionally replace the complete branch list using CSV or TSV. Each record has label, from, to, resistance, tolerancePercent and enabled; enabled must be true or false. The exact header is optional. Invalid imports preserve the existing network.
  4. Inspect the equivalent resistance and source results, then select a branch to compare voltage, signed current and dissipated power with the schematic and ledger. Read the reason for any open, shorted, floating or indeterminate result.
  5. Enable Compare entered resistor tolerances to inspect terminal bounds. Correct or disable invalid tolerance entries before requesting the complete CSV, or use the identical selectable CSV text. These bounds do not establish individual component ratings.

The Formula

The mathematical logic powering this calculation is:

One ideal DC voltage source fixes the potential of source terminal A relative to source terminal B. Branch current is positive from the entered From node to the To node. For a positive resistor, Iij = (Vi − Vj) / Rij and Pij = (Vi − Vj)² / Rij. Power dissipated by a resistor is nonnegative even when its signed current is negative.
At each non-source node, Kirchhoff's current law gives Σj (Vi − Vj) / Rij = 0. The calculator solves these simultaneous node equations with exact rational arithmetic. Series and parallel formulas are special cases: Rseries = ΣR and 1/Rparallel = Σ(1/R). Bridge connections do not need to be manually reduced.
Enabled zero-resistance branches contract their endpoints into one electrical node. Disabled branches are open connections. Equivalent resistance is found from the terminal network independently of the entered voltage, so a finite network still has a meaningful resistance at zero source voltage. Open and shorted terminal connections are explicit states.
For a finite network, Isource = Vsource / Req and Psource = Vsource × Isource. With a nonzero voltage across an ideal terminal short, no finite operating solution satisfies the source constraint. With a zero-voltage short, source current is indeterminate rather than automatically zero. Ideal-wire cycle currents are not assigned an arbitrary equal split.
For an enabled tolerance t, Rlow = R(1 − t/100) and Rhigh = R(1 + t/100). Rayleigh monotonicity gives equivalent-resistance bounds by solving all positive resistors at their lower and upper limits. At fixed source voltage, source current and power follow from those terminal bounds; signed current endpoints are ordered numerically. These are deterministic allowed-value bounds, not probability intervals or bounds for individual branch currents and powers.
Node potential is measured relative to the selected source reference. An isolated floating component has no determined absolute potential; source-free finite resistors within it carry zero current. Diagram crossings do not connect branches unless their entered endpoints share a node.
Inputs permit 2–12 nodes, 1–24 branches, resistance zero or 1e−12 through 1e12 Ω, and source voltage zero or magnitude 1e−12 through 1e6 V. Authored decimals/scientific notation allow 24 significant digits and 48 effective decimal places; tolerance allows 0–50% with at most 12 effective decimal places. Exact arithmetic has a bounded size and reports an arithmetic limit instead of a guessed answer. Display values may be rounded; the ledger and CSV retain exact fractions.
This is a passive, linear DC model. It does not model AC reactance, nonlinear devices, multiple sources, temperature, lead resistance, source impedance, transient behavior or component power-rating suitability.

Worked Example

If you input:

  • Number of nodes: 3
  • Source terminal A: A
  • Reference terminal B: B
  • Source voltage: 12
  • Voltage unit: Volts (V)
  • Resistance unit: Ohms (Ω)
  • Compare entered resistor tolerances: Yes
  • Import format: CSV (comma separated)
  • Branches to paste: label,from,to,resistance,tolerancePercent,enabled R1,A,C,100,5,true R2,C,B,200,5,true R3,C,B,300,5,true

Result:

At 12 V, the 200 Ω and 300 Ω branches from C to B combine to 120 Ω. Adding the 100 Ω branch from A to C gives 220 Ω equivalent resistance. Source current is 3/55 A, approximately 0.0545455 A, and total power is 36/55 W, approximately 0.654545 W. Node C is 72/11 V above B. The three branch currents are 3/55, 9/275 and 6/275 A; their dissipations are 36/121, 648/3025 and 432/3025 W. Independent ±5% resistor intervals give 209–231 Ω equivalent resistance and source-current bounds of 4/77 to 12/209 A. These terminal bounds are not individual branch-power limits.

Frequently Asked Questions

Can this solve circuits that are not simple series or parallel combinations?

Yes. Enter the endpoint nodes of each resistor, including parallel branches and bridge connections. The model uses Kirchhoff's current law to solve node voltages, then derives branch current and dissipation. It supports one ideal DC voltage source and up to 12 nodes and 24 branches; it is not a general electronic-device or AC simulator.

How do I enter wires and open branches?

An enabled branch with zero resistance is an ideal wire, so its endpoints share a potential. Disable a branch to make it open; its stored resistance and tolerance remain editable but do not affect the nominal circuit. Malformed disabled resistance must still be corrected before changing resistance units, because a unit conversion must not silently reinterpret retained text.

Why can an ideal wire or a shorted source have an unavailable current?

The ideal circuit may not determine how current divides between wire paths around a zero-resistance loop. The calculator reports that ambiguity instead of assuming an equal split. A nonzero ideal voltage applied across a wire short is inconsistent, so no finite operating currents or powers are supplied. At zero voltage across a terminal short, source current remains indeterminate; source power is zero. Equivalent resistance still identifies the short as zero.

What do a negative current and a floating node mean?

A negative branch current flows opposite its entered From-to-To orientation. Reversing the source polarity reverses solved currents without making resistor dissipation negative. A floating component has no determined voltage relative to the source reference. Its source-free finite resistors can have known zero voltage differences and currents even though its absolute node potentials are unavailable.

Are the tolerance results worst-case limits for every component?

No. For independent positive-resistance intervals on this fixed passive network, monotonicity bounds equivalent resistance using all-low and all-high resistor values. The fixed source voltage then gives source-current and source-power bounds. Individual branch current and power can redistribute differently, so those quantities are not advertised as bounded by the same two solves. Tolerance is not a probability distribution. Invalid active tolerance leaves nominal analysis available but blocks the complete export until corrected or disabled.

Can I use the calculated power to choose a resistor rating?

The result is ideal steady DC dissipation for the entered values, not a component-rating recommendation. Actual selection depends on the manufacturer's rating conditions, temperature, derating, transients and other circuit details that this tool does not model. The diagram is a connectivity schematic, not a wiring or physical-layout instruction.

How are precision, very small results and imports handled?

Decimal and scientific input strings are parsed exactly within declared limits; blank or malformed active inputs are not turned into zero. Calculations use reduced rational arithmetic, with explicit work-size limits. Display approximations and exact fractions are distinguished, including small nonzero values and truly balanced zero-current branches. CSV/TSV imports require exactly six columns, 1–24 records and no blank records or quoted line breaks. Labels can use CSV quote escaping, and exports protect spreadsheet formula-like labels.