Battery Pulse Voltage & Cutoff Calculator

Enter two comparable loaded voltage readings for each of two batteries. Fit a line through each pair and compare voltage and headroom at a shared current inside the measured ranges. Find the exact cutoff crossing or determine whether the full measured span meets the entered voltage limit.

Battery load comparison

Compare battery voltage under measured load

Battery A
Battery B

Both batteries meet the cutoff at the selected current.

Battery A highest qualifying current
6 A
Inside its entered current span
Battery B highest qualifying current
8 A
Inside its entered current span

Measured current and fitted terminal voltage

Each line stays inside its measured current span. The horizontal dashed line is the cutoff.

  • Battery A
  • Battery B

Battery A at 6 A

12 V fitted

0 V margin to cutoff

Battery B at 6 A

12.1 V fitted

0.1 V margin to cutoff

Review the exact pulse comparison

Battery A fitted line details
Fitted resistance
1/10 Ω
Fitted intercept
63/5 V
Measured current span
2 to 10 A
Battery B fitted line details
Fitted resistance
1/20 Ω
Fitted intercept
62/5 V
Measured current span
2 to 10 A

How to use this calculator

  1. Enter one shared current to inspect and the voltage cutoff from the comparison conditions.
  2. Enter each battery’s lower and higher measured current and measured voltage.
  3. Compare the estimated voltage, signed headroom and highest qualifying current inside each range.
  4. Inspect the fitted lines and exact fraction ledger, and download the worksheet.

The Formula

The mathematical logic powering this calculation is:

For lower current I₁ and higher current I₂ with measured voltages V₁ and V₂, fitted resistance R = (V₁−V₂)/(I₂−I₁). The fitted intercept is V₁+I₁R. Within [I₁,I₂], estimated voltage at I is V₁−(I−I₁)R. Voltage headroom is estimated voltage minus the entered cutoff. An exact zero margin meets the cutoff.
If V₂ is at least the cutoff, all measured-range currents meet it and the highest is I₂. If V₁ is below the cutoff, no current in the entered range meets it. Otherwise the highest passing current is I₁+(V₁−cutoff)/R. Equal measured voltages use a flat fit. Report the chosen current as outside the model if it falls outside either battery’s entered range.
Use already recorded readings at comparable charge state, temperature, pulse duration and measurement timing. This is two-point interpolation, with no predictions of run time, permissible discharge current, heating or protection behavior.

Worked Example

If you input:

  • Battery A: 12.4 V at 2 A; 11.6 V at 10 A
  • Battery B: 12.3 V at 2 A; 11.9 V at 10 A
  • Comparison: 6 A with a 12 V cutoff

Result:

A meets the cutoff exactly at 6 A and B reads 12.1 V in the model. The highest measured-range currents that meet the cutoff are 6 A for A and 8 A for B.

Frequently Asked Questions

Is the fitted intercept an actual open-circuit reading?

It is an intercept of the fitted line. It equals an entered zero-current reading when the lower observation was at zero.

Why is the comparison unavailable outside either measured range?

The estimates are confined to interpolation. You can inspect each battery’s stated range and change the current to a point they both cover.

Can the cutoff equal a measured or interpolated voltage?

Yes. Exact equality belongs to the passing range, including a range that consists of its lower measured current alone.

What if voltage rises at higher current?

This model uses a non-increasing fit. Recheck that the two entered observations are comparable, or use a different analysis for increasing or nonlinear behavior.

Is the cutoff current a rated discharge limit?

It is a boundary from the entered voltage data and cutoff only. Equipment ratings, protection limits and time-dependent behavior come from other specifications.

Similar Calculators