Capacitor Series/Parallel & Voltage Share Calculator
Compare two ideal capacitor arrays at the same user-entered applied voltage. Use measured capacitances or add explicit lower and upper values. See which group has the largest voltage share, where a calculated range crosses an entered ceiling and what applied-voltage bound follows from all declared ceilings.
Compare capacitance and group voltage
Trace two series/parallel arrays from entered device capacitances. Compare ideal voltage shares and the effect of independent capacitance ranges.
Edit source and capacitor groups
Groups connect in series, and the devices in each group share one voltage. Enter per-device capacitance. Leave unknown ceilings blank.
A · Uneven series
Parallel pair
Single group
B · Matched groups
First pair
Second pair
Equivalent capacitance across both arrays
The band spans the entered capacitance limits. The dot is nominal and the gold line is your minimum target.
- Capacitance range
- 57.6 µF to 75.428571429 µF
- Nominal capacitance
- 66.666666667 µF
Range crosses capacitance target
Range crosses an entered ceiling
- Capacitance range
- 90 µF to 110 µF
- Nominal capacitance
- 100 µF
Range meets capacitance target
Within entered voltage ceilings
Group voltage and applied-voltage bound
Uneven series
Bound from entered ceilings
11.6875 V
Range crosses an entered ceiling
- Applied voltage
- 12 V
- Ceilings entered
- 2 of 2
- Limiting groups
- Single group
Charge and energy
- Nominal series charge
- 800 µC
- Charge range
- 691.2 µC to 905.142857143 µC
- Nominal stored energy
- 4.8 mJ
- Stored energy range
- 4.1472 mJ to 5.430857143 mJ
Each voltage band reflects one group at its own lower and upper shares. The gold line marks an entered ceiling.
Parallel pair
2 in parallel · Entered range
- Voltage range
- 3.272727273 V to 4.888888889 V
- Nominal voltage
- 4 V
- Entered group ceiling
- 7.5 V
- Group capacitance
- 200 µF
- Applied bound from this group
- 18.409090909 V
Within entered voltage ceilings
Single group
1 in parallel · Entered range
- Voltage range
- 7.111111111 V to 8.727272727 V
- Nominal voltage
- 8 V
- Entered group ceiling
- 8.5 V
- Group capacitance
- 100 µF
- Applied bound from this group
- 11.6875 V
Range crosses an entered ceiling
Show selectable CSV
How to use this calculator
- Enter one applied voltage and choose capacitance units. An optional minimum capacitance target applies to both arrays.
- Add each group in series. Enter identical parallel count and nominal capacitance per device within each group.
- Choose nominal-only or enter the lower and upper capacitance. Enter documented group voltage ceilings to compare them.
- Compare equivalent capacitance, then select an array to inspect its per-group voltage and applied-voltage bound.
- Download the full comparison, including exact capacitance, charge, energy and voltage quantities.
The Formula
The mathematical logic powering this calculation is:
Each array consists of parallel groups connected in series. One group can contain one or more capacitors sharing the same voltage. Enter a per-device nominal capacitance and the number of devices in the group. Group capacitance is their sum. For devices with the same authored value or range, multiply each capacitance by the count. A single group gives the parallel-only case; groups of one give the series-only case.
For group capacitances Cᵢ, the equivalent capacitance is 1 ÷ Σ(1 ÷ Cᵢ). The model assumes linear ideal capacitors and initially uncharged internal nodes. Each series group acquires the same charge Q = Cₑ × V, where V is the applied voltage. Group voltage is Q ÷ Cᵢ. The nominal group voltage shares sum to one, and their voltages sum to the applied voltage. At a given voltage, charge and stored energy follow the equivalent capacitance. Stored energy is Cₑ × V² ÷ 2.
The nominal-only input uses one fixed value. Range input requires both per-device endpoints surrounding the nominal. The equivalent capacitance is smallest with every group at its lower capacitance and largest with every group at its upper capacitance. To find the largest voltage share of one group, put that group at its lower capacitance and all other groups at their upper capacitance. The smallest share uses the opposite combination. The stage ranges refer to independent endpoint combinations, so their simultaneous extrema generally do not sum to the source voltage. Multiply each share by the applied voltage for its voltage interval.
The optional capacitance target is a minimum. Equality at the lower end meets it across the entered range. An interval entirely below the target misses it. Compare each group’s voltage interval to its authored ceiling. A group can touch its ceiling and meet the comparison at exact equality. When the lower group voltage exceeds the ceiling, the entire interval is above it. When only the upper voltage exceeds it, the interval crosses the ceiling. The smallest quotient of entered group ceiling divided by that group’s largest share gives the applied-voltage bound for the entered ceilings. Missing ceilings remain unresolved even when the known checks pass. A zero ceiling produces a known zero bound.
The worksheet accepts one to eight groups per array and one to sixteen parallel devices per group. Positive per-device capacitance ranges from 0.000001 pF through 1 mF. Minimum equivalent target is optional, from zero to 16 mF. Applied voltage and any group ceilings accept 0–48 V. These are computational worksheet limits. Numeric entries allow twelve decimal places or exact fractions. Unit switches preserve capacitances and their target. Calculations and CSV use exact rational values. Rounded display values leave comparison decisions unchanged.
The comparison represents ideal electrostatic division. Actual capacitor behavior can depend on leakage, trapped charge, voltage-dependent capacitance, temperature, transients and component design. Use the entered ceilings as comparison criteria for ideal values. Practical voltage distribution and equipment decisions require their own evidence.Worked Example
If you input:
- Applied voltage: 12 V
- Minimum capacitance: 60 µF
- Uneven series: One pair of 100 µF devices with 80–120 µF each, in series with one 100 µF device at 90–110 µF
- Voltage ceiling: 7.5 V on the parallel pair and 8.5 V on the single group
- Matched groups: Two parallel pairs in series, each device 100 µF with a 90–110 µF range. A 7 V ceiling applies to each group.
Result:
The uneven series array is 66.666666667 µF at nominal and spans 57.6–75.428571429 µF. The single group can reach 8.727272727 V, so its range crosses the entered 8.5 V ceiling. The corresponding bound on applied voltage is 11.6875 V. The matched array is 100 µF nominal and spans 90–110 µF. Both modeled group ranges meet their entered 7 V ceilings.
Frequently Asked Questions
How do I calculate total capacitance in series and parallel?
Add capacitances within each parallel group. Then add the reciprocals of all series-group capacitances and take the reciprocal of that sum.
Which capacitor group sees the most voltage?
At nominal capacitances, the smallest group carries the greatest voltage for a positive source voltage in this ideal model. Range results reflect each group’s smallest and largest possible capacitance.
Why do the top ends of all the voltage ranges add to more than the source?
Each top end belongs to its own endpoint combination. The group being examined is low while its neighbors are high. The nominal voltages use one network and reconcile to the source voltage.
How do I enter an unknown voltage ceiling?
Leave it blank. The worksheet compares any ceilings you recorded and preserves the distinction between a complete and partial set.
Does the calculated applied-voltage bound describe real component behavior?
It is the smallest bound implied by the entered ceilings under ideal electrostatic division. Actual voltage distribution can be affected by leakage, temperature and circuit behavior outside this model.
Similar Calculators
Passive Filter Bode Plot & Load Planner
Plot gain and phase for two loaded RC or series RLC filters. Compare cutoff shifts, half-power frequencies and source-referenced gain at your test frequency.
Equivalent Resistance Calculator
Solve a DC resistor network, including series, parallel and bridge connections. Inspect node voltages, branch currents, power and terminal tolerance bounds.
AC Power & Power Factor Calculator
Calculate AC watts, vars, volt-amps and power factor for single-phase or balanced three-phase loads. Combine leading and lagging loads, compare an ideal target PF and export the ledger.
Series RLC Step Response & Ringdown Calculator
Compare two series RLC transients. Inspect damping, capacitor voltage, current and energy after a constant source step or during source-free ringdown.
Capacitor Precharge Resistor Window Calculator
Find the nominal resistor range that satisfies an inrush cap and precharge deadline across resistor and capacitor tolerances.