VSWR Calculator & Reflection Sweep Audit
Enter measured reflection magnitude or finite VSWR at up to twelve frequencies. Compare entered uncertainty bounds with a VSWR ceiling. Trace which measured samples give the largest reflection and see how far apart the sampled points are.
Compare measured reflection and VSWR
Check sample ranges against a VSWR ceiling and see which measured frequencies determine the result.
Edit samples and ceiling
Leave both window endpoints blank to analyze all sample frequencies. Enter VSWR as a number such as 2 for 2:1.
Sample 1 · 900 MHz
Sample 2 · 925 MHz
Sample 3 · 950 MHz
Sample 4 · 975 MHz
Sample 5 · 1000 MHz
Sample 6 · 1025 MHz
Reflection by measured frequency
Vertical marks show the entered bounds. Dots show stated readings. Select a sample for its values.
Within the VSWR ceiling
Within the VSWR ceiling
Range crosses the ceiling
Entirely above the ceiling
Within the VSWR ceiling
Outside analyzed window
Coverage of the entered points
Sample spacing
- Analyzed samples
- 5 of 6
- First analyzed point
- 900 MHz
- Last analyzed point
- 1,000 MHz
- Largest sample spacing
- 25 MHz
- Window start to first point
- 0 MHz
- Last point to window end
- 0 MHz
Worst analyzed endpoint
- Sample frequencies
- 975 MHz
- Upper reflection magnitude
- 0.444444444
- Upper VSWR
- 2.6:1
- Upper reflected power
- 19.75308642%
- Ceiling reflected power
- 11.111111111%
Consecutive within-limit samples
- 900 MHz through 925 MHz · 2 samples
- 1,000 MHz · 1 sample
The results describe the sampled frequencies. Reflection between measurements remains unresolved.
Selected frequency
975 MHz
Measured magnitude and ratio
- Input format
- VSWR · Entered bounds
- Stated reflection magnitude
- 0.411764706
- Reflection magnitude range
- 0.375 to 0.444444444
- Stated VSWR
- 2.4:1
- VSWR range
- 2.2:1 to 2.6:1
- Ceiling check
- Entirely above the ceiling
Reflected power and return loss
- Stated reflected fraction
- 16.955017301%
- Reflected-power range
- 14.0625% to 19.75308642%
- Stated return loss
- 7.70701763 dB
- Return-loss range
- 7.04365036 dB to 8.51937465 dB
Return loss is a logarithmic display. The ceiling check uses exact reflection magnitude.
Show selectable CSV
How to use this calculator
- Enter a finite VSWR ceiling and, if useful, the endpoints of an analysis window.
- Enter the recorded sample frequencies in order and choose magnitude or finite VSWR for each sample.
- Choose stated readings or supply lower and upper measured bounds.
- Select a point on the sample list to inspect its magnitude, VSWR, reflected power and return loss.
- Review sample coverage and export the measurements and comparison results.
The Formula
The mathematical logic powering this calculation is:
Reflection magnitude ρ is the absolute value of the complex reflected-to-incident wave ratio. Enter a measured magnitude from zero to one, or enter a finite voltage standing-wave ratio S of at least one. A finite ratio converts to ρ = (S − 1) ÷ (S + 1). To convert back, use S = (1 + ρ) ÷ (1 − ρ) where ρ is below one. At full reflection the finite ratio fails to exist because its denominator is zero.
The reflected-power fraction for the same reference basis is ρ². Positive return loss is −20 × log₁₀(ρ) dB. At full reflection, return loss is 0 dB. At magnitude zero, the return loss has no finite value. VSWR and reflected power rise as the magnitude rises. Positive return loss falls, so its lower endpoint comes from the upper reflection endpoint. The chart and ceiling test use magnitude, and the displayed return loss is logarithmic.
Choose Stated reading to evaluate one entered value or Entered bounds to supply a lower and upper reading that enclose it. For a finite authored VSWR ceiling, convert it exactly to a magnitude ceiling. A sample is within the limit when its largest entered magnitude meets or equals that ceiling. It is entirely above when its smallest magnitude is greater. Otherwise the sample crosses the ceiling. The square of the limit gives the corresponding reflected-power fraction.
The analysis uses only entered measurements inside the optional frequency window, including its endpoints. With a blank window it considers all entered points. A worst bound can tie across multiple measured samples. The tool reports the first and last analyzed frequencies, largest separation between consecutive analyzed points, and empty distances to the authored window edges. Where consecutive samples meet the ceiling, the list describes that sequence of discrete points. It leaves the behavior between those points unresolved.
Use one to twelve samples, entered in strictly increasing frequency order. Frequency accepts 1 Hz through 1,000 GHz equivalent in kHz, MHz or GHz. A finite authored VSWR accepts 1 through 1 billion. Values accept up to 12 decimal places or exact fractions. Unit switching preserves physical frequency. Magnitude, VSWR, reflected fraction and threshold classifications use exact rational arithmetic. Return-loss figures are approximate displays and do not enter the comparisons.
Use readings sharing the relevant measurement reference conditions. The worksheet compares passive magnitude data for the submitted points. Magnitude omits phase, so the results cannot reconstruct complex impedance or determine what happens in unmeasured intervals.Worked Example
If you input:
- VSWR ceiling and analysis window: 2:1 across the entered 900–1,000 MHz window
- 900 and 925 MHz: Magnitude 0.16–0.20 and VSWR 1.4:1–1.6:1 respectively
- 950 and 975 MHz: Magnitude 0.28–0.36 and VSWR 2.2:1–2.6:1 respectively
- 1,000 and 1,025 MHz: Stated magnitude zero and one respectively. The latter lies outside the selected window.
Result:
Five sampled points are inside the window. Three are within the ceiling, one crosses it and one is entirely above. The largest analyzed upper VSWR is 2.6:1 at 975 MHz, equivalent to 19.75308642% reflected power. The spacing between consecutive analyzed samples is 25 MHz.
Frequently Asked Questions
How do I calculate VSWR from reflection magnitude?
For a magnitude below one, add one to the magnitude and divide by one minus the magnitude. Magnitude one has no finite VSWR.
What is the difference between reflection magnitude and reflected power?
Magnitude is the amplitude ratio. Squaring it gives the reflected-power fraction on the same reference basis.
Why is high return loss associated with low reflection?
Positive return loss is minus twenty times the base-ten logarithm of reflection magnitude. A smaller magnitude produces a larger positive result.
How does the worksheet handle a reading that touches my ceiling?
The comparison includes exact equality. A whole sample interval can meet the ceiling if its upper endpoint equals that ceiling.
Can I treat passing samples as a continuous bandwidth?
Each result describes the entered frequency only. The sample list and gap summary show where the worksheet has evidence, without establishing behavior between measurements.
Similar Calculators
Wavelength & Phase Path Calculator
Calculate frequency and wavelength in up to four media. Compare path delay, wrapped phase and the shared frequency range for entered lengths.
Passive Filter Bode Plot & Load Planner
Plot gain and phase for two loaded RC or series RLC filters. Compare cutoff shifts, half-power frequencies and source-referenced gain at your test frequency.
Antenna Length & Dipole Cut Planner
Compare two half-wave dipole wire lengths from the ARRL estimate or a measured reference. Check per-arm cut allowance and wire stock across your frequency band.
Impedance Matching Calculator & L-Network Smith Chart
Match a measured complex load to a real reference at one frequency. Compare valid series and shunt reactive branches on a Smith chart.