Wheatstone Bridge Balance & Tolerance Calculator
Enter three fixed arms and compare two candidate resistors for the fourth arm of a Wheatstone bridge. Calculate the exact null, identify the full resistance range within an entered residual voltage limit, and see whether each candidate remains inside that limit throughout its stated tolerance. Switch between an ideal open detector and a finite input resistance.
Find a bridge’s null and tolerance window
Compare bottom right resistors against a residual limit with a finite or open detector.
Only candidate A stays within the limit across its full tolerance.
Signal across each resistor tolerance
Shading marks the accepted residual within ±25 mV. The dot is the nominal signal.
Candidate A
Full tolerance fitsLow signal -17.857143 mVHigh signal 25 mVNominal 0 mV
Candidate B
Part of the tolerance fitsLow signal -25.000067 mVHigh signal 16.509354 mVNominal -7.812573 mV
Review the exact bridge audit
Candidate A values
- Resistance tolerance
- 750 to 1250 Ω
- Exact nominal in this mode
- 0 mV
- Exact open nominal
- 0 mV
Candidate B values
- Resistance tolerance
- 3300003/4000 to 1100001/800 Ω
- Exact nominal in this mode
- -12500125/1600001 mV
- Exact open nominal
- -50000500/2100001 mV
The signal is the left midpoint minus the right midpoint. The acceptable window includes finite positive endpoints.
How to use this calculator
- Enter your positive DC supply and the three fixed arm resistances. Resistance is in ohms.
- Choose a finite detector input resistance or select the open-circuit detector model. Enter the maximum absolute residual signal in millivolts.
- Enter two nominal resistors and their tolerances for the bottom right arm. The current model evaluates the full interval for each candidate.
- Review each signed signal range, the ideal null and the acceptable resistance window. Download the exact fraction audit.
The Formula
The mathematical logic powering this calculation is:
R₁ and R₂ are the top and bottom resistances on the left. R₃ and R₄ are the top and bottom on the right. Report the left midpoint minus the right midpoint. With an open detector, ΔV = Vₛ[R₂/(R₁ + R₂) − R₄/(R₃ + R₄)]. The null is R₄ = R₂R₃/R₁; a positive finite detector does not move the null.
For detector resistance D, multiply the open voltage by D/[D + (R₁∥R₂) + (R₃∥R₄)]. With the other arms and detector fixed, this is a strictly decreasing linear fractional function of R₄. The endpoints of its positive-resistance domain come from R₄ = 0 (excluded) and R₄ → ∞. Solve ΔV = +limit and ΔV = −limit for any finite bounds within that domain. If the limit covers an asymptote, that side does not impose a positive finite bound.
A candidate with nominal resistance R and tolerance t% has inclusive endpoints R(1−t/100) and R(1+t/100). The output extrema occur at those endpoints. If both are within ±limit, the entire candidate tolerance fits. A partial fit means only some values fit. This ideal DC worksheet holds the other arms and supply fixed. It does not include wire resistance, temperature effects, detector offset or component power checks.Worked Example
If you input:
- Supply and fixed arms: 1 V ideal supply; 1,000 Ω for each fixed arm
- Detector: 500 Ω input resistance; absolute residual limit 25 mV
- Candidate A: 1,000 Ω ± 25%
- Candidate B: 1,100.001 Ω ± 25%
Result:
The exact null is 1,000 Ω and the acceptable range is 750–1,375 Ω. Candidate A’s 750–1,250 Ω fits, including its 25 mV boundary. Candidate B reaches 1,375.00125 Ω, so only part of its tolerance fits.
Frequently Asked Questions
Does detector loading move the ideal null?
No. When both midpoints have equal voltage, no current flows through the detector. Any positive finite detector resistance leaves that exact null at the same fourth arm value.
What does the signed residual mean?
It is the left midpoint voltage minus the right midpoint voltage. Its sign identifies the higher midpoint. The acceptance limit applies to its absolute value.
Why do the two candidate spans differ?
The tolerance is a percentage of each nominal resistance. The mapping from bottom right arm resistance to loaded voltage is also curved, so equal resistance changes do not have equal voltage effects on both sides of the null.
What happens when the limit is zero?
Only the exact null qualifies. A nonzero tolerance containing the null has a partial fit, while a nominal value at the null with zero tolerance has a full fit.
Which resistors contribute tolerances in this worksheet?
Only the bottom right candidate. Use measured fixed-arm values if available. Changes in supply, the other arms, lead resistance or detector offset can move the measured results.
Similar Calculators
Thévenin Equivalent Calculator & Load Audit
Find Thévenin voltage and resistance for a resistive bridge or divider. Compare loaded terminal voltage, current, power and measurement error.
Equivalent Resistance Calculator
Solve a DC resistor network, including series, parallel and bridge connections. Inspect node voltages, branch currents, power and terminal tolerance bounds.
Ohm's Law Calculator
Calculate voltage, current, or resistance using Ohm's Law — enter any two values to find the third.
Four-Wire Resistivity & Conductivity Calculator
Find bulk resistivity and conductivity from two measured four-wire runs. Remove a constant voltage offset and compare exact uncertainty bands at one temperature.