Range Hood CFM & Published Pressure Calculator
Check published airflow and static pressure points at the documented fan speed and duct configuration. Interpolate only within the entered pressure range. Compare a separately recorded airflow measurement and its uncertainty with the same target.
Compare range hood airflow at documented pressure
Use published rating points and a measured CFM interval to check your entered airflow target.
Hood A’s published airflow estimate reaches the target.
Target 285 CFM at 0.2 in. w.g..
Hood A
286.666667 CFM
Interpolated from two published points
Above the entered airflow target.
Highest supported pressure at target 0.2125 in. w.g..
Hood B
280 CFM
Interpolated from two published points
Below the entered airflow target.
Highest supported pressure at target 0.175 in. w.g..
Published airflow across static pressure
The plot stops at each hood’s final documented point.
Independent field measurement
The field measurement interval overlaps the target.
Recorded 287 ± 3 CFM · interval 284–290 CFM.
Edit the documented pressure and airflow target
Edit both published rating tables
Use each hood’s published points from one speed and duct configuration. Enter increasing pressures in table order.
Edit the independent field measurement
Enter a recorded airflow and its stated tolerance. This interval uses the target from the comparison.
Review exact airflow and measurement calculations
Hood A
Pressure bracket 1/10 to 1/4 in. w.g..
Airflow 860/3 CFM · airflow minus target 5/3 CFM.
Exact highest supported pressure 17/80 in. w.g..
Hood B
Pressure bracket 1/10 to 1/4 in. w.g..
Airflow 280 CFM · airflow minus target -5 CFM.
Exact highest supported pressure 7/40 in. w.g..
Field interval 284 to 290 CFM from the entered nominal reading and tolerance.
Show range hood CSV text
How to use this calculator
- Set a documented static pressure and your project airflow target.
- Copy table points at the same speed and duct configuration for each candidate.
- Compare plotted airflow and the highest entered-domain pressure at which each reaches the target.
- If a commissioned field airflow reading is available, add its documented tolerance and review its separate interval.
- Download the comparison and exact rational audit.
The Formula
The mathematical logic powering this calculation is:
Copy two to four pressure and airflow pairs for each exact fan configuration, speed and table. Pressure must increase strictly, and airflow must be non-increasing. Use documented static pressure in inches water gauge and airflow in CFM. Free-air maximum power ratings are a separate benchmark unless the table identifies the value as a comparable pressure point.
At a published point use its entered airflow. Within successive points (P₀, Q₀) and (P₁, Q₁), use linear interpolation Q = Q₀ + (P − P₀)(Q₁ − Q₀)/(P₁ − P₀). Outside the bracket leave airflow unavailable. This curve interpolates entered points with exact decimal arithmetic. It does not model installed duct losses or actual hood capture.
For the same airflow target, find the highest pressure within the entered domain where airflow meets or exceeds that target. Traverse a flat segment at the exact target to its highest pressure. If the final rated point still meets the target, report that point as the end of the entered range. When the target exceeds all entered airflow values the inverse is unavailable.
An independent field record has a nominal measured CFM and a symmetric entered tolerance. Its interval runs from max(0, measured − tolerance) to measured + tolerance. Compare its lower and upper endpoints separately against the target. An interval entirely at or above the target reaches it. An interval entirely below misses it. A remaining interval overlaps it. The field measurement has its own result and does not modify the published airflow comparison.
This worksheet compares documented pressure-dependent CFM and a recorded measurement. Use the same documented configuration at each entered point. Installation, pressure testing, pollutant capture, safety, make-up air and code checks are separate.Worked Example
If you input:
- Compared pressure: 0.20 in. w.g.
- Entered target: 285 CFM
- Hood A: BBN2 vertical rectangular: 300 CFM at 0.10 and 280 CFM at 0.25 in. w.g.
- Hood B: BBN2 horizontal rectangular: 300 CFM at 0.10 and 270 CFM at 0.25 in. w.g.
- Illustrative field measurement: 287 ± 3 CFM
Result:
At 0.20 in. w.g., Hood A interpolates to about 286.667 CFM and Hood B to 280 CFM. The 284–290 CFM independent field interval overlaps 285 CFM.
Frequently Asked Questions
Why does pressure matter for range hood airflow?
The labeled CFM value depends on the pressure under which a complete hood was tested. Use the matched table rather than comparing raw blower maxima.
What happens outside the published pressure points?
The worksheet leaves that airflow estimate open. A plotted or tabulated value at the needed pressure supplies the extra coverage.
What if two pressure points have the target airflow?
The inverse selects the highest pressure in the entered interval at which the airflow remains at least the target, including the end of a flat segment.
Does an entered field measurement replace the product rating?
It is viewed separately and compared with the same typed airflow target. It does not change the shape of the published curve.
Can this calculate the needed airflow from my cooktop rating?
Enter the target from your own specification. The worksheet models how the entered ratings and readings relate to that target.
Similar Calculators
Bathroom Fan CFM Calculator & Humidity Timer
Compare two delivered bathroom exhaust airflows and see the modeled humidity at timer shutoff. Calculate the airflow or runtime for an entered target.
HVAC Duct Pressure & Airflow Planner
Compare round and rectangular duct paths at a prescribed airflow. Visualize pressure losses, check entered pressure and velocity preferences, and export energy estimates.
Compressed Air Demand & Receiver Planner
Compare compressor CFM and receiver storage against timed demand. Visualize pressure reserve, recharge and unserved air, with exact stage ledgers and CSV export.
Pump Curve & Operating Point Planner
Compare pump curves and speeds against system head. Visualize operating flow, runtime, electrical energy and whether your target volume fits the available hours.
Range Hood Height Calculator & Chimney Cover Fit
Compare requested range hood clearance with two documented chimney cover ranges and the measured ceiling height and tolerance.
Exhaust Fan CFM & Curve Operating Point Calculator
Compare airflow where two exhaust fan pressure curves meet the same path. Find all modeled intersections and check them against an entered CFM band.