Motor Torque & Duty Cycle Calculator

Enter an output-speed schedule with ramps, steady motion and dwell. Compare two entered motor and transmission ratios against the same motion and signed output load. See what demands peak torque, whether a higher ratio changes the speed constraint, and which portions of the motion supply or return mechanical work.

Motor sizing

Compare motor options for the same move

Drive options and entered limits

The ratio is motor RPM divided by output RPM. Include motor and transmission inertia on their respective shafts.

Option A
Option B

Output motion and load

Each phase ramps to its ending RPM. Use the same positive direction for speed and required load torque.

Phase 1

Starts at 0 rpm

Phase 2

Starts at 600 rpm

Phase 3

Starts at 600 rpm

Phase 4

Starts at 0 rpm

Option A meets the entered limits.

Option B exceeds its speed limit.

Option A

Reflected inertia0.05 kg·m²

Peak torque
7.5531 N·m
Limit 8 N·m · phase 3Within
RMS torque
4.8618 N·m
Limit 5 N·mWithin
Maximum speed
1,200 rpm
Limit 1,500 rpmWithin
Shaft work supplied
1,888.2917 J
Shaft work returned
474.575 J
Net shaft work
1,413.7167 J

Option B

Reflected inertia0.0125 kg·m²

Peak torque
4.4049 N·m
Limit 5 N·m · phase 3Within
RMS torque
2.6772 N·m
Limit 3 N·mWithin
Maximum speed
2,400 rpm
Limit 2,000 rpmExceeded
Shaft work supplied
1,967.2486 J
Shaft work returned
553.5319 J
Net shaft work
1,413.7167 J
Motor demand over time
Motor torque by time for both motor options4 phases over 8 seconds. Motor torque is in N·m. Option A peaks at 7.5531 newton-meters; Option B at 4.4049 newton-meters.-7.55-3.7803.787.5508Elapsed time (s)

Vertical scale in N·m. Dashed vertical guides divide phases. Negative power returns mechanical work.

Shaft work assumes an ideal transmission. Returned work is shown as a positive magnitude. The comparison uses three independent entered limits.

View phase and work ledger
Motor demands by phase
PhaseOptionTime (s)Motor speed (rpm)Inertia torque (N·m)Load torque (N·m)Total torque (N·m)Shaft power (W)Work supplied (J)Work returned (J)Net work (J)
1Option A0 → 20 → 1,2005.02652.57.52650 → 945.8139945.81390945.8139
1Option B0 → 20 → 2,4002.82741.254.07740 → 1,024.77081,024.770801,024.7708
2Option A2 → 51,200 → 1,20002.52.5314.1593 → 314.1593942.47780942.4778
2Option B2 → 52,400 → 2,40001.251.25314.1593 → 314.1593942.47780942.4778
3Option A5 → 61,200 → 0-10.05312.5-7.5531-949.1501 → 00474.575-474.575
3Option B5 → 62,400 → 0-5.65491.25-4.4049-1,107.0638 → 00553.5319-553.5319
4Option A6 → 80 → 00000 → 0000
4Option B6 → 80 → 00000 → 0000
Show copyable CSV

How to use this calculator

  1. Choose a repeating cycle or single pass and enter the starting output RPM and driven inertia.
  2. Enter the duration, ending output RPM and signed load torque for each phase. A phase inherits the previous phase’s ending speed. Split a reversal into multiple phases if the applied load changes direction.
  3. Enter each option’s motor-to-output speed ratio, input-side inertia, and three quoted limits.
  4. Compare required peak torque, RMS torque and maximum speed. Switch the trace to speed or power and expand the phase ledger for timing and energy.
  5. Export the CSV to keep the modeled phases, assumptions and results.

The Formula

The mathematical logic powering this calculation is:

Ratio r = motor speed ÷ output speed. Enter the output-side inertia and the motor-side inertia for each option, including transmission inertia at the relevant shaft. Motor-side total inertia J = input inertia + output inertia ÷ r². Each phase changes the output speed linearly. Motor angular acceleration is the signed motor RPM change × π ÷ (30 × phase seconds).

Required motor torque = J × motor angular acceleration + signed output-load torque ÷ r. Peak demand is the largest absolute torque in any phase. RMS torque = √[sum of (motor torque² × phase seconds) ÷ total seconds]. Maximum speed is the largest absolute motor RPM at any phase endpoint. The three individually entered bounds are compared independently. They do not describe a motor’s full torque–speed envelope.

Shaft power = motor torque × signed angular velocity. Positive power supplies mechanical work and negative power returns it. Integrate each linear power segment, splitting any crossing of zero into its two parts. Returned energy is displayed as a positive magnitude. Net work is output load work plus the change in modeled rotational kinetic energy, avoiding loss of a small net value when large exchanges nearly cancel. A steady hold at zero speed uses zero mechanical work even with nonzero shaft torque. Electrical consumption, recovery and motor heating depend on equipment beyond this calculation.

Choose 1–12 phases, 0.001–3,600 seconds per phase, output speeds from −30,000 to 30,000 rpm, and signed load torque from −1,000,000 to 1,000,000 N·m. Inertias accept 0–10,000 kg·m², ratios 0.01–100, entered torque limits 0.000001–1,000,000 N·m and speed limits 0.000001–3,000,000 rpm. Enter up to six decimals. Repeat cycles must end at their starting speed. Comparisons use numerical roundoff tolerance at an entered boundary.

Worked Example

If you input:

  • Driven inertia and initial speed: 0.2 kg·m² at 0 rpm
  • Repeating cycle: Ramp to 600 rpm over 2 s, hold for 3 s, brake to 0 rpm in 1 s, idle for 2 s
  • Output-load effort: 5 N·m across the first three phases and 0 N·m during idle
  • Option A: 2:1 ratio, 0.03 kg·m², limits 8 N·m peak, 5 N·m RMS and 1,500 rpm
  • Option B: 4:1 ratio, 0.01 kg·m², limits 5 N·m peak, 3 N·m RMS and 2,000 rpm

Result:

A needs 7.5531 N·m peak, 4.8618 N·m RMS and 1,200 rpm. B needs 4.4049 N·m peak, 2.6772 N·m RMS and 2,400 rpm. B exceeds its entered speed limit despite lower torque demand. Both perform about 1,413.7167 J net modeled mechanical work.

Frequently Asked Questions

Why does a higher ratio change torque and speed differently?

The motor turns faster at a given output speed, while output-load torque and driven inertia reflect back by different factors. The motor’s own inertia does not shrink with the ratio.

What should I enter for signed output-load torque?

Enter the shaft torque needed to counter the load, using the same positive direction as the RPM entry. If load effort changes sign during a phase, divide the movement into phases with matching loads.

Why does the RMS result include dwell?

RMS averages squared torque over the complete entered time. Include dwell at its actual holding torque, whether that torque is zero or nonzero.

Does returned energy mean it goes back to the power supply?

Returned energy measures negative mechanical work at the modeled motor shaft. The drive may store, dissipate or recover that work depending on the equipment.

Why must a repeating profile return to its starting RPM?

Otherwise joining two cycles would require an instantaneous unmodeled change in speed. For a move without a return phase, choose Single pass.

Do the three limits establish motor suitability?

They are checks against separately entered limits. Actual suitability also depends on simultaneous torque and speed ratings, peak duration, the drive, cooling, gear losses and mechanical constraints.