Parallel Pipe Flow Split Calculator
Use two to four series of pressure-drop measurements for parallel pipes with common endpoints. See the common drop, each branch’s flow, and where the measured ranges stop supporting a request.
Find the flow split between parallel pipes
Use measured branch curves to find one pressure drop and the flow through each branch.
Branch measurements and request
Enter branch ID, flow in L/min, and pressure drop in kPa. Start each branch with 0 flow and 0 drop.
Use nonnegative values with up to six decimal places.
The branch curves cover the request.
Flow split at the requested point
- Common pressure drop
- 3.5 kPa
- Combined flow
- 10 L/min
- Shared measurement limit
- 7 kPa · 16 L/min
- Branches setting the limit
- B
Branch A
6.5 L/min65%
Branch B
3.5 L/min35%
- Total
- Branch A
- Branch B
Open circles mark entered samples for branch A. The square marks its flow at the pressure shown.
Branch A measurement bracket
- Lower sample
- 1 kPa · 4 L/min
- Upper sample
- 5 kPa · 8 L/min
Flow is interpolated between these two samples.
Combined curve between 2 kPa and 5 kPa.
Export the flow split audit
View CSV text
How to use this calculator
- Enter a branch ID, flow in litres per minute and pressure drop in kilopascals on each line.
- Start each branch at zero and list its other points in increasing order.
- Choose known total flow or known pressure drop, then inspect the branch split and the measured range.
- Select a branch to see the two samples used and export the complete exact audit.
The Formula
The mathematical logic powering this calculation is:
Enter steady passive branches that connect the same two points. Each branch sees the same difference between those points, and the branch flows add to the total. Use pressure-drop samples that represent a common pressure reference and comparable conditions. Each series starts at zero flow and zero drop, then strictly increases in both quantities.
For pressure p between branch samples (p₀,Q₀) and (p₁,Q₁), interpolate Q(p) = Q₀ + (p − p₀)(Q₁ − Q₀)/(p₁ − p₀). Add each branch’s interpolated flow at the given pressure. The maximum shared pressure is the smallest of the branches’ final sampled pressures. Collect all sample-pressure knots up to that limit. Between adjacent knots the sum is linear and strictly increasing.
With a requested total flow, find the two combined knots enclosing it and invert that segment by linear interpolation. Evaluate every branch at the resulting common pressure. With a requested pressure, evaluate the branches directly. The range includes both endpoints. Any request above the common range shows the limiting point and the excess in the input quantity. Branch shares divide by combined flow when it is positive.
Use 2–4 branches, each with 2–7 points. Samples accept 0 to 1,000,000 L/min and kPa. The known total accepts up to 4,000,000 L/min. Values use at most six decimal places. Arithmetic and bounds are exact for the entered piecewise-linear curves. The results depend on the measured data and unchanged flow configuration between samples.Worked Example
If you input:
- Branch A (flow, drop): (0,0), (4,1), (8,5), (10,9)
- Branch B (flow, drop): (0,0), (2,2), (5,5), (7,7)
- Known total: 10 L/min
Result:
The common drop is 3.5 kPa. Branches A and B carry 6.5 and 3.5 L/min. Branch B sets the shared measured limit at 7 kPa and 16 L/min combined.
Frequently Asked Questions
Why is the pressure drop the same in each branch?
Each route runs between the same inlet and outlet. The difference between those reference points is shared. The branch’s own curve determines its flow at that difference.
Why does the chart stop before one branch’s last sample?
The combined curve requires coverage by every branch. The lowest final sample pressure sets the common limit, even if other branches have readings above it.
What do the points in the branch bracket show?
They are the measured samples used to interpolate that branch’s flow. When the common pressure is an observed sample, both bracket values display that one sample.
Does solving from pressure give the same split as solving from flow?
Yes for a matching pressure and total within the shared data range. The positive slopes make the combined relationship invertible.
Similar Calculators
Measured Pump Head Calculator & Tap Audit
Calculate pump head from recorded suction and discharge pressures, pipe sizes, elevations and flow. Compare measured head and entered loss corrections.
Pipe Pressure Drop Calculator
Compare pipe pressure loss across inside diameters. Calculate Darcy friction, fitting losses, velocity and Reynolds number with explicit transition limits.
Pump Curve & Operating Point Planner
Compare pump curves and speeds against system head. Visualize operating flow, runtime, electrical energy and whether your target volume fits the available hours.