Heat Pump vs Gas Furnace Operating Cost Calculator

Use the same weather and heating demand for both systems. A heat pump can use less purchased energy when its COP is higher, but its operating cost also depends on the electricity rate and how much heat it can supply in cold bins. Compare actual modeled heat supplied before reading the energy costs for the entered period.

Heating energy comparison

Compare heat pump and gas furnace energy costs

Use the same heating demand across outdoor temperatures. Compare the heat each system delivers and the energy it buys.

Energy rates and furnace

Enter illustrative or documented marginal energy prices, useful output and effective furnace fuel efficiency. AFUE is a seasonal proxy.

Nonoverlapping weather bins

Use separate hours and document heat pump COP and available output for the same condition and delivery basis.

Bin 1
Bin 2
Bin 3

Gas furnace is $49.22 lower on the entered load.

52.8 MMBtu of demand across 2,400 entered hours.

Heat pump

$1,017.22

5,651.246 kWh purchased

Delivered
52.8 MMBtu
Unserved
0 MMBtu

Gas furnace

$968.00

586.6667 therms purchased

Delivered
52.8 MMBtu
Unserved
0 MMBtu

Demand and delivered heat by bin

Bars share a scale in MMBtu over each bin’s hours. The dotted portion shows heat left unserved.

7 °F · 200 h

Heat pump8 MMBtu delivered
Gas furnace8 MMBtu delivered

27 °F · 800 h

Heat pump22.4 MMBtu delivered
Gas furnace22.4 MMBtu delivered

47 °F · 1,400 h

Heat pump22.4 MMBtu delivered
Gas furnace22.4 MMBtu delivered

Energy cost per MMBtu delivered

Equal-cost heat pump COP

2.8775 COP

These unit rates apply to heat a system can deliver. Capacity and totals for the entered hours are shown separately.

7 °FGas furnace lower

Heat pump$29.31
Gas furnace$18.33

27 °FGas furnace lower

Heat pump$20.29
Gas furnace$18.33

47 °FHeat pump lower

Heat pump$14.65
Gas furnace$18.33
Open weather-bin ledger
Heating consumption and demand ledger
Outdoor binSystemDemandDeliveredUnservedPurchased energyEnergy cost
7 °FHeat pump8 MMBtu8 MMBtu0 MMBtu1,302.5922 kWh$234.47
7 °FGas furnace8 MMBtu8 MMBtu0 MMBtu88.8889 therms$146.67
27 °FHeat pump22.4 MMBtu22.4 MMBtu0 MMBtu2,525.0248 kWh$454.50
27 °FGas furnace22.4 MMBtu22.4 MMBtu0 MMBtu248.8889 therms$410.67
47 °FHeat pump22.4 MMBtu22.4 MMBtu0 MMBtu1,823.629 kWh$328.25
47 °FGas furnace22.4 MMBtu22.4 MMBtu0 MMBtu248.8889 therms$410.67
Show copyable CSV

How to use this calculator

  1. Collect disjoint hours and useful heating requirements at representative outdoor temperatures from the same building or heating zone.
  2. Enter the documented COP and usable heat pump output for each temperature basis. Keep the useful heat basis consistent across both systems.
  3. Enter the effective furnace fuel efficiency and useful output, plus each marginal energy rate from your utility bill.
  4. Review served heat and shortfalls before reading the energy cost ranking. Compare per-unit marginal rates and export the full worksheet.

The Formula

The mathematical logic powering this calculation is:

For each separate set of hours, multiply useful heating load by the number of hours. Each system’s delivered heat is hours times the smaller of useful load and available useful output. Unserved heat is demand minus delivered heat. Enter comparable performance measured at the same delivery basis and temperature conditions. Outdoor temperature labels the bin; the model does not use temperature to extrapolate load or performance.

Use 3.412 kBtu/kWh and 100 kBtu/therm from EIA as the worksheet conversion constants. A heat pump’s purchased electricity equals delivered kBtu ÷ (3.412 × heating COP). The furnace’s therms equal delivered kBtu ÷ (100 × effective fuel efficiency expressed as a fraction). Multiply each by the entered unit energy price. DOE defines COP on matching energy units and AFUE across the heating season. Enter a single effective furnace efficiency for this model. A label AFUE can only serve as an estimating assumption; the model applies the value uniformly.

Sum supplied heat, shortfalls and exact energy charges across all entered hours, then round for display. Compare the energy costs as a ranking only when each system supplies the whole positive demand for every bin. Marginal electricity cost per MMBtu supplied is 1,000 × electricity price ÷ (3.412 × COP); gas is 10 × gas price ÷ the efficiency fraction. At a positive gas price the equivalent COP is electricity price × 100 × efficiency fraction ÷ (3.412 × gas price). This expression compares equal heat supplied and is independent of capacity. Zero gas price has no finite unique crossover unless the unit rates are at parity for every COP because both prices are zero.

Enter one to ten unique representative temperatures from −80 to 100 °F, with nonoverlapping durations of at least 0.001 h and total hours no greater than 8,784. Enter useful output and demand rates from 0 to 300 kBtu/h, COP 0.1–15, efficiency 1–100%, electricity $0–$15/kWh and gas $0–$60/therm. Input precision is up to three decimals. Use representative equipment data and marginal energy rates. Entered prices and conditions are illustrative. This model excludes installation, fixed service fees, cooling, standby and fan electricity for the furnace, backup heat, defrost or cycling effects not captured in the COP, and any added distribution losses. The report covers only the entered hours.

Worked Example

If you input:

  • Heating profile: 47 °F for 1,400 h at 16 kBtu/h, 27 °F for 800 h at 28 kBtu/h, 7 °F for 200 h at 40 kBtu/h.
  • Heat pump: COP 3.6/2.6/1.8; useful output 36/31/42 kBtu/h at those respective conditions.
  • Furnace and rates: 50 kBtu/h useful output, effective efficiency 90%, $1.65/therm and $0.18/kWh.

Result:

Both supply 52.8 MMBtu in these bins. The heat pump uses 5,651.246 kWh for $1,017.22 and the furnace uses 586.6667 therms for $968.00. The gas energy cost is $49.22 lower for this same entered load. At the stated rates, equal energy cost per MMBtu corresponds to a heat pump COP of about 2.8775.

Frequently Asked Questions

What does COP mean here?

Heating COP is heat delivered divided by electrical energy required, both expressed in comparable units. Use a documented value representative of each entered condition.

Why does the comparison need both COP and available output?

COP determines the energy required per unit of heat. Available useful output determines how much of the entered heating demand the system could supply for that bin.

Why is a cost total shown when a system misses part of the load?

The total prices the heat that system delivered. The ranking is withheld whenever either system leaves a shortfall, because the systems then provide different amounts of heat.

Can I use the furnace AFUE?

A documented AFUE number can serve as a simplifying assumption for effective fuel efficiency. AFUE is a seasonal metric and does not specify a separate efficiency at every temperature or cover the gas furnace’s electrical use.

Does the equivalent COP show when to switch equipment?

It only identifies the equal energy price per unit of heat under entered rates. Weather, equipment capacity, controls and backup are outside that calculation.

How do I represent my heating season?

Enter distinct temperature bins whose hours do not overlap. Use your own load and equipment data; additional heating, cooling or standby hours are never filled in automatically.