Heat Pump vs Gas Furnace Operating Cost Calculator
Use the same weather and heating demand for both systems. A heat pump can use less purchased energy when its COP is higher, but its operating cost also depends on the electricity rate and how much heat it can supply in cold bins. Compare actual modeled heat supplied before reading the energy costs for the entered period.
Compare heat pump and gas furnace energy costs
Use the same heating demand across outdoor temperatures. Compare the heat each system delivers and the energy it buys.
Energy rates and furnace
Enter illustrative or documented marginal energy prices, useful output and effective furnace fuel efficiency. AFUE is a seasonal proxy.
Nonoverlapping weather bins
Use separate hours and document heat pump COP and available output for the same condition and delivery basis.
Gas furnace is $49.22 lower on the entered load.
52.8 MMBtu of demand across 2,400 entered hours.
Heat pump
5,651.246 kWh purchased
- Delivered
- 52.8 MMBtu
- Unserved
- 0 MMBtu
Gas furnace
586.6667 therms purchased
- Delivered
- 52.8 MMBtu
- Unserved
- 0 MMBtu
Demand and delivered heat by bin
Bars share a scale in MMBtu over each bin’s hours. The dotted portion shows heat left unserved.
7 °F · 200 h
27 °F · 800 h
47 °F · 1,400 h
Energy cost per MMBtu delivered
Equal-cost heat pump COP
2.8775 COP
These unit rates apply to heat a system can deliver. Capacity and totals for the entered hours are shown separately.
7 °FGas furnace lower
27 °FGas furnace lower
47 °FHeat pump lower
Open weather-bin ledger
| Outdoor bin | System | Demand | Delivered | Unserved | Purchased energy | Energy cost |
|---|---|---|---|---|---|---|
| 7 °F | Heat pump | 8 MMBtu | 8 MMBtu | 0 MMBtu | 1,302.5922 kWh | $234.47 |
| 7 °F | Gas furnace | 8 MMBtu | 8 MMBtu | 0 MMBtu | 88.8889 therms | $146.67 |
| 27 °F | Heat pump | 22.4 MMBtu | 22.4 MMBtu | 0 MMBtu | 2,525.0248 kWh | $454.50 |
| 27 °F | Gas furnace | 22.4 MMBtu | 22.4 MMBtu | 0 MMBtu | 248.8889 therms | $410.67 |
| 47 °F | Heat pump | 22.4 MMBtu | 22.4 MMBtu | 0 MMBtu | 1,823.629 kWh | $328.25 |
| 47 °F | Gas furnace | 22.4 MMBtu | 22.4 MMBtu | 0 MMBtu | 248.8889 therms | $410.67 |
Show copyable CSV
How to use this calculator
- Collect disjoint hours and useful heating requirements at representative outdoor temperatures from the same building or heating zone.
- Enter the documented COP and usable heat pump output for each temperature basis. Keep the useful heat basis consistent across both systems.
- Enter the effective furnace fuel efficiency and useful output, plus each marginal energy rate from your utility bill.
- Review served heat and shortfalls before reading the energy cost ranking. Compare per-unit marginal rates and export the full worksheet.
The Formula
The mathematical logic powering this calculation is:
For each separate set of hours, multiply useful heating load by the number of hours. Each system’s delivered heat is hours times the smaller of useful load and available useful output. Unserved heat is demand minus delivered heat. Enter comparable performance measured at the same delivery basis and temperature conditions. Outdoor temperature labels the bin; the model does not use temperature to extrapolate load or performance.
Use 3.412 kBtu/kWh and 100 kBtu/therm from EIA as the worksheet conversion constants. A heat pump’s purchased electricity equals delivered kBtu ÷ (3.412 × heating COP). The furnace’s therms equal delivered kBtu ÷ (100 × effective fuel efficiency expressed as a fraction). Multiply each by the entered unit energy price. DOE defines COP on matching energy units and AFUE across the heating season. Enter a single effective furnace efficiency for this model. A label AFUE can only serve as an estimating assumption; the model applies the value uniformly.
Sum supplied heat, shortfalls and exact energy charges across all entered hours, then round for display. Compare the energy costs as a ranking only when each system supplies the whole positive demand for every bin. Marginal electricity cost per MMBtu supplied is 1,000 × electricity price ÷ (3.412 × COP); gas is 10 × gas price ÷ the efficiency fraction. At a positive gas price the equivalent COP is electricity price × 100 × efficiency fraction ÷ (3.412 × gas price). This expression compares equal heat supplied and is independent of capacity. Zero gas price has no finite unique crossover unless the unit rates are at parity for every COP because both prices are zero.
Enter one to ten unique representative temperatures from −80 to 100 °F, with nonoverlapping durations of at least 0.001 h and total hours no greater than 8,784. Enter useful output and demand rates from 0 to 300 kBtu/h, COP 0.1–15, efficiency 1–100%, electricity $0–$15/kWh and gas $0–$60/therm. Input precision is up to three decimals. Use representative equipment data and marginal energy rates. Entered prices and conditions are illustrative. This model excludes installation, fixed service fees, cooling, standby and fan electricity for the furnace, backup heat, defrost or cycling effects not captured in the COP, and any added distribution losses. The report covers only the entered hours.Method sources
Worked Example
If you input:
- Heating profile: 47 °F for 1,400 h at 16 kBtu/h, 27 °F for 800 h at 28 kBtu/h, 7 °F for 200 h at 40 kBtu/h.
- Heat pump: COP 3.6/2.6/1.8; useful output 36/31/42 kBtu/h at those respective conditions.
- Furnace and rates: 50 kBtu/h useful output, effective efficiency 90%, $1.65/therm and $0.18/kWh.
Result:
Both supply 52.8 MMBtu in these bins. The heat pump uses 5,651.246 kWh for $1,017.22 and the furnace uses 586.6667 therms for $968.00. The gas energy cost is $49.22 lower for this same entered load. At the stated rates, equal energy cost per MMBtu corresponds to a heat pump COP of about 2.8775.
Frequently Asked Questions
What does COP mean here?
Heating COP is heat delivered divided by electrical energy required, both expressed in comparable units. Use a documented value representative of each entered condition.
Why does the comparison need both COP and available output?
COP determines the energy required per unit of heat. Available useful output determines how much of the entered heating demand the system could supply for that bin.
Why is a cost total shown when a system misses part of the load?
The total prices the heat that system delivered. The ranking is withheld whenever either system leaves a shortfall, because the systems then provide different amounts of heat.
Can I use the furnace AFUE?
A documented AFUE number can serve as a simplifying assumption for effective fuel efficiency. AFUE is a seasonal metric and does not specify a separate efficiency at every temperature or cover the gas furnace’s electrical use.
Does the equivalent COP show when to switch equipment?
It only identifies the equal energy price per unit of heat under entered rates. Weather, equipment capacity, controls and backup are outside that calculation.
How do I represent my heating season?
Enter distinct temperature bins whose hours do not overlap. Use your own load and equipment data; additional heating, cooling or standby hours are never filled in automatically.
Similar Calculators
HVAC Replacement & Operating Cost Planner
Compare HVAC replacement quotes, annual heating and cooling costs, maintenance and dated repairs. Visualize nominal and discounted costs, savings and payback reversals.
Mini-Split Zone Capacity & Quote Planner
Compare mini-split installation quotes against matched room and outdoor-unit capacities. See individual and shared shortfalls at one common rating point.
Room Heat Loss & Retrofit Calculator
Explore room heat loss and sensible cooling, compare envelope and ventilation retrofits, and visualize heat flows and outdoor-temperature sensitivity with exact CSV ledgers.
Hydronic Radiator Output & Water Temperature Planner
Compare hot-water radiator output by room. Check changing supply and return temperatures, room shortfalls and modeled minimum supply.
Furnace BTU Calculator for Output & Load Coverage
Compare documented low- and high-stage furnace output against the same heating loads. See unmet BTU, modeled runtime and fuel totals.
Geothermal Thermal Response Test Calculator
Fit a measured geothermal borehole thermal response trace. Compare ground conductivity, residuals and heat input stability across two time windows.