Room Heat Loss & Retrofit Calculator
Understand which rooms lose heat, which components matter, and how authored retrofit assumptions change the balance. Model up to twelve independently controlled rooms with external or fixed-temperature surfaces, shared partitions, infiltration, mechanical outdoor ventilation and explicit internal/solar gains. Compare three alternatives under three conditions and inspect a weather sweep that includes every in-range room balance temperature. This is a steady-state sensible heat-balance explorer for checking assumptions and comparing options. It is not a complete HVAC load calculation, Manual J or MCS assessment, equipment-sizing recommendation, latent cooling model or annual energy forecast. Enter your own areas, U-values, air properties and design temperatures; no building, climate or equipment data are inferred.
See where the heat goes.
Compare room heat balances, envelope improvements and ventilation recovery under your own winter and summer assumptions. Steady-state sensible loads—not equipment sizing.
Examples are editable assumptions. Enter net areas and known U-values; air infiltration and supplied outdoor ventilation are separate. Each room is held at its own target temperature.
Existing assumptions: ≈ 1,356.31 W heating and 0 W sensible cooling.
Your room heat balance
Outdoor temperature: −5 °C · Heating room targets. Positive losses require heating; gains can create sensible cooling demand.
Heating and cooling can both be positive. Transfers between rooms cancel in the building net but still affect each room.
Retrofit comparison
| Alternative | Heating (W) | Sensible cooling (W) | Signed net (W) |
|---|---|---|---|
| Existing assumptions | ≈ 1,356.31 W | 0 W | ≈ 1,356.31 W |
| Illustrative envelope and recovery | ≈ 448.58 W | 0 W | ≈ 448.58 W |
Alternative multipliers apply to external/fixed-boundary U-values and infiltration. Heat recovery applies only to mechanical ventilation. Shared partitions and gains are unchanged.
Outdoor-temperature sensitivity
- Existing assumptions
- Illustrative envelope and recovery
Full sensitivity table · all alternatives
| Outdoor temperature | Alternative | Heating | Sensible cooling | Signed net |
|---|---|---|---|---|
| −15 °C | Existing assumptions | ≈ 1,968.21 W | 0 W | ≈ 1,968.21 W |
| −15 °C | Illustrative envelope and recovery | ≈ 709.31 W | 0 W | ≈ 709.31 W |
| −12.25 °C | Existing assumptions | ≈ 1,799.93 W | 0 W | ≈ 1,799.93 W |
| −12.25 °C | Illustrative envelope and recovery | ≈ 637.61 W | 0 W | ≈ 637.61 W |
| −9.5 °C | Existing assumptions | 1,631.66 W | 0 W | 1,631.66 W |
| −9.5 °C | Illustrative envelope and recovery | ≈ 565.91 W | 0 W | ≈ 565.91 W |
| −6.75 °C | Existing assumptions | ≈ 1,463.39 W | 0 W | ≈ 1,463.39 W |
| −6.75 °C | Illustrative envelope and recovery | ≈ 494.21 W | 0 W | ≈ 494.21 W |
| −5 °C | Existing assumptions | ≈ 1,356.31 W | 0 W | ≈ 1,356.31 W |
| −5 °C | Illustrative envelope and recovery | ≈ 448.58 W | 0 W | ≈ 448.58 W |
| −4 °C | Existing assumptions | ≈ 1,295.12 W | 0 W | ≈ 1,295.12 W |
| −4 °C | Illustrative envelope and recovery | 422.51 W | 0 W | 422.51 W |
| −1.25 °C | Existing assumptions | ≈ 1,126.84 W | 0 W | ≈ 1,126.84 W |
| −1.25 °C | Illustrative envelope and recovery | ≈ 350.81 W | 0 W | ≈ 350.81 W |
| 1.5 °C | Existing assumptions | 958.57 W | 0 W | 958.57 W |
| 1.5 °C | Illustrative envelope and recovery | ≈ 279.11 W | 0 W | ≈ 279.11 W |
| 4.25 °C | Existing assumptions | ≈ 790.3 W | 0 W | ≈ 790.3 W |
| 4.25 °C | Illustrative envelope and recovery | ≈ 207.41 W | 0 W | ≈ 207.41 W |
| 7 °C | Existing assumptions | ≈ 622.03 W | 0 W | ≈ 622.03 W |
| 7 °C | Illustrative envelope and recovery | ≈ 135.71 W | 0 W | ≈ 135.71 W |
| 9.75 °C | Existing assumptions | ≈ 453.75 W | 0 W | ≈ 453.75 W |
| 9.75 °C | Illustrative envelope and recovery | ≈ 64.01 W | 0 W | ≈ 64.01 W |
| ≈ 10.84 °C | Existing assumptions | ≈ 386.9 W | 0 W | ≈ 386.9 W |
| ≈ 10.84 °C | Illustrative envelope and recovery | ≈ 35.53 W | 0 W | ≈ 35.53 W |
| 12.5 °C | Existing assumptions | 285.48 W | 0 W | 285.48 W |
| 12.5 °C | Illustrative envelope and recovery | ≈ 8.52 W | ≈ 16.2 W | ≈ −7.69 W |
| ≈ 13.02 °C | Existing assumptions | ≈ 253.5 W | 0 W | ≈ 253.5 W |
| ≈ 13.02 °C | Illustrative envelope and recovery | 0 W | ≈ 21.31 W | ≈ −21.31 W |
| 15.25 °C | Existing assumptions | ≈ 117.21 W | 0 W | ≈ 117.21 W |
| 15.25 °C | Illustrative envelope and recovery | 0 W | ≈ 79.39 W | ≈ −79.39 W |
| ≈ 16.36 °C | Existing assumptions | ≈ 49.07 W | 0 W | ≈ 49.07 W |
| ≈ 16.36 °C | Illustrative envelope and recovery | 0 W | ≈ 108.42 W | ≈ −108.42 W |
| ≈ 17.63 °C | Existing assumptions | 0 W | ≈ 28.67 W | ≈ −28.67 W |
| ≈ 17.63 °C | Illustrative envelope and recovery | 0 W | ≈ 141.54 W | ≈ −141.54 W |
| 18 °C | Existing assumptions | 0 W | ≈ 51.07 W | ≈ −51.07 W |
| 18 °C | Illustrative envelope and recovery | 0 W | ≈ 151.09 W | ≈ −151.09 W |
| 20.75 °C | Existing assumptions | 0 W | ≈ 219.34 W | ≈ −219.34 W |
| 20.75 °C | Illustrative envelope and recovery | 0 W | ≈ 222.78 W | ≈ −222.78 W |
| 23.5 °C | Existing assumptions | 0 W | 387.61 W | −387.61 W |
| 23.5 °C | Illustrative envelope and recovery | 0 W | ≈ 294.48 W | ≈ −294.48 W |
| 26.25 °C | Existing assumptions | 0 W | ≈ 555.88 W | ≈ −555.88 W |
| 26.25 °C | Illustrative envelope and recovery | 0 W | ≈ 366.18 W | ≈ −366.18 W |
| 29 °C | Existing assumptions | 0 W | ≈ 724.16 W | ≈ −724.16 W |
| 29 °C | Illustrative envelope and recovery | 0 W | ≈ 437.88 W | ≈ −437.88 W |
| 31.75 °C | Existing assumptions | 0 W | ≈ 892.43 W | ≈ −892.43 W |
| 31.75 °C | Illustrative envelope and recovery | 0 W | ≈ 509.58 W | ≈ −509.58 W |
| 34.5 °C | Existing assumptions | 0 W | 1,060.7 W | −1,060.7 W |
| 34.5 °C | Illustrative envelope and recovery | 0 W | ≈ 581.28 W | ≈ −581.28 W |
| 37.25 °C | Existing assumptions | 0 W | ≈ 1,228.97 W | ≈ −1,228.97 W |
| 37.25 °C | Illustrative envelope and recovery | 0 W | ≈ 652.98 W | ≈ −652.98 W |
| 40 °C | Existing assumptions | 0 W | ≈ 1,397.25 W | ≈ −1,397.25 W |
| 40 °C | Illustrative envelope and recovery | 0 W | 724.68 W | −724.68 W |
Where each room gains and loses heat
Each component uses one shared magnitude scale, ±364 W. Left is heat entering the room; right is heat leaving. Internal and solar gains are shown on the left.
Living room
Signed demand: ≈ 874.19 W
Bedroom
Signed demand: 482.12 W
| Room | Target | Heating | Sensible cooling | Outdoor balance |
|---|---|---|---|---|
| Living room | 21 °C | ≈ 874.19 W | 0 W | ≈ 17.63 °C |
| Bedroom | 19 °C | 482.12 W | 0 W | ≈ 16.36 °C |
A balance temperature solves zero signed demand for that room and these assumptions. It can lie outside the displayed sweep.
Shared-partition transfers
| Partition | From room | To room | Signed from → to | Conductance |
|---|---|---|---|---|
| Shared partition | Living room | Bedroom | 20 W | 10 W/K |
Positive transfer follows the entered from → to direction; negative transfer runs the other way. Building partition total: 0 W.
Complete component and surface ledger
| Room | Envelope | Infiltration | Mechanical ventilation | Partition loss | Internal gain | Solar gain | Signed demand |
|---|---|---|---|---|---|---|---|
| Living room | 364 W | ≈ 326.63 W | 313.56 W | 20 W | 150 W | 0 W | ≈ 874.19 W |
| Bedroom | 256.5 W | 180.9 W | 144.72 W | −20 W | 80 W | 0 W | 482.12 W |
| Room / surface | Net area | Effective U-value | Boundary temperature | Conductance | Signed heat loss |
|---|---|---|---|---|---|
| Living room / Living external wall | 20 m² | 0.4 W/(m²·K) | −5 °C | 8 W/K | 208 W |
| Living room / Living glazing | 4 m² | 1.5 W/(m²·K) | −5 °C | 6 W/K | 156 W |
| Bedroom / Bedroom external wall | 15 m² | 0.4 W/(m²·K) | −5 °C | 6 W/K | 144 W |
| Bedroom / Bedroom glazing | 2 m² | 1.5 W/(m²·K) | −5 °C | 3 W/K | 72 W |
| Bedroom / Floor to fixed boundary | 15 m² | 0.3 W/(m²·K) | 10 °C | 4.5 W/K | 40.5 W |
| Quantity | Value |
|---|---|
| Envelope | 620.5 W |
| Infiltration | ≈ 507.53 W |
| Mechanical ventilation | 458.28 W |
| Shared partitions | 0 W |
| Internal gains | 230 W |
| Solar gains | 0 W |
| Signed net | ≈ 1,356.31 W |
| Heating | ≈ 1,356.31 W |
| Sensible cooling | 0 W |
Export the complete comparison
Includes every condition, alternative, room, surface, partition and sweep point. Exact SI and display-unit values are included; spreadsheet software may reinterpret fractions or round large numbers.
Edit your assumptions
Rooms
Volume is enclosed air volume. ACH describes infiltration only; mechanical flow is supplied outdoor air. Gains are explicit sensible watts, not occupant or sunlight estimates.
1. Living room
2. Bedroom
External & fixed-boundary surfaces
Enter net areas: deduct windows from walls, then enter windows separately. Fixed boundaries use an assumed adjacent/ground temperature; this is not a ground-coupling solver.
1. Living external wall
2. Living glazing
3. Bedroom external wall
4. Bedroom glazing
5. Floor to fixed boundary
Shared partitions
Enter each pair of modeled rooms once. Partition U-values stay unchanged across retrofit alternatives. Remove or reassign dependencies before deleting a room.
1. Shared partition
Conditions
Choose which room targets apply. Gain multipliers from 0 to 2 apply to every room. Conditions are independent steady cases, not hours of an annual simulation.
1. Winter night
2. Summer sensible balance
Retrofit alternatives
A multiplier of 1 keeps the entered assumption; 0.5 halves it. Recovery reduces mechanical sensible exchange only. Zero U/ACH factors and 100% recovery are idealized cases.
1. Existing assumptions
2. Illustrative envelope and recovery
Air properties & weather sweep
Density and heat capacity are authored SI assumptions in both unit modes. All coefficients stay constant across the sweep. Fields accept up to six decimal places or exact fractions; blanks remain invalid.
How to use this calculator
- Start with Two-room retrofit example, or Partition-only example to see simultaneous room heating and cooling. Choose metric or imperial display units; existing quantities are preserved.
- Expand Rooms and enter enclosed volume, heating/cooling targets, infiltration ACH, mechanical outdoor airflow and explicit sensible gains. Enter density and heat capacity under Air properties & weather sweep when your assumptions differ.
- Enter net External & fixed-boundary surfaces with U-values. Do not double-count window areas. Add each Shared partition once between two rooms; fixed boundaries represent an assumed unmodeled adjacent temperature.
- Define Conditions with outdoor temperatures, target sets and internal/solar multipliers. Define Retrofit alternatives with external/fixed U and infiltration multipliers plus mechanical sensible recovery.
- Select a condition and alternative. Compare heating and sensible cooling separately, inspect the shared-scale weather curves, room component bars, partition transfers and complete ledgers. A room balance temperature can lie outside the sweep.
- Download CSV or show the selectable CSV text to retain every modeled condition, alternative and component. Complete highlighted fields before exporting; review the method limits before using the result in a design decision.
The Formula
The mathematical logic powering this calculation is:
Use canonical SI quantities and exact rational arithmetic. Volumetric air heat capacity Cv = air density × specific heat, in J/(m³·K). For each external or fixed-boundary surface, conductance H = net area × U-value × alternative U multiplier. Signed heat loss = H × (room target − boundary temperature). Outdoor surfaces follow the condition temperature; fixed surfaces retain their authored boundary temperature. Enter windows separately and deduct their areas from walls.
Infiltration conductance = Cv × room volume × ACH × infiltration multiplier / 3600. Mechanical outdoor ventilation conductance = Cv × flow in L/s / 1000 × (1 − sensible recovery percentage / 100). Multiply each by (room target − outdoor temperature) for its signed loss. Recovery does not reduce infiltration.
For a shared partition, H = area × U. Signed from-to transfer = H × (from-room target − to-room target). Add that loss to the from-room and subtract it from the to-room. Enter each room pair once. Shared partitions are not scaled by the external retrofit multiplier and cancel exactly in the building net.
Room signed demand = envelope + infiltration + mechanical ventilation + partition loss − internal gain × condition multiplier − solar gain × condition multiplier. Room heating = max(0, signed demand); sensible cooling = max(0, −signed demand). Building heating and cooling are sums of room requirements, not clamps of the building net. Both can be positive at once. Heating-target/cooling-target selection chooses temperatures only; it does not force the demand sign.
For an outdoor sweep, room demand Q(T) = K − Hout × T, where Hout includes outdoor surfaces and both air-exchange conductances but excludes fixed boundaries and shared partitions. The balance temperature is K/Hout when Hout is positive. If Hout is zero, demand is either zero at all temperatures or has no outdoor-temperature balance. The shared grid contains 21 evenly spaced points, the selected outdoor temperature if within bounds, and every in-range room balance temperature across alternatives. Coefficients and gains remain constant.
Input limits: 1–12 rooms, 0–48 external/fixed surfaces, 0–24 distinct shared partitions, 1–3 conditions and 1–3 alternatives. Volume and area must be positive and at most 1000000 SI units; U-values 0–20 W/(m²·K), ACH 0–50, mechanical flow 0–100000 L/s, each sensible gain 0–100000000 W. Room targets −20 to 60°C with heating no greater than cooling; outdoor/fixed/sweep temperatures −80 to 80°C. Sweep minimum must be less than maximum. Multipliers 0–2, recovery 0–100%, density 0.1–5 kg/m³ and heat capacity 100–5000 J/(kg·K). These numerical bounds are not recommended construction assumptions.
Inputs accept up to six decimal places and twelve significant digits, or exact fractions with numerator/denominator components up to 32 digits. Invalid drafts suppress dependent results and exports. Metric/imperial switches preserve quantities exactly or explain why conversion cannot proceed. Rounded input displays retain exact converted values until edited. Tiny nonzero results remain identified rather than rounded to zero. CSV includes exact SI and selected-unit values for every condition, alternative and sweep point; spreadsheet imports may reinterpret fractions or round large numbers.
Not included: latent moisture loads, dynamic thermal storage, time-dependent solar/shading, detailed thermal bridges, duct losses, equipment efficiency/defrost, shared controls or airflow redistribution, climate selection and full design-load standards. Each room is held independently at its target. Use an appropriate recognized design method and qualified equipment selection for actual HVAC sizing.Worked Example
If you input:
- Rooms: Living: 75 m³, 21/24°C heating/cooling targets, 0.5 ACH, 10 L/s ventilation, 150 W internal and 300 W solar gains. Bedroom: 45 m³, 19/25°C, 0.5 ACH, 5 L/s, 80 W internal and 100 W solar gains.
- Surfaces: Living: 20 m² wall at U 0.4 and 4 m² glazing at U 1.5. Bedroom: 15 m² wall at U 0.4, 2 m² glazing at U 1.5, and 15 m² floor at U 0.3 to a fixed 10°C boundary. U-values are W/(m²·K).
- Partition: 10 m² at U 1 between living and bedroom.
- Conditions: Winter −5°C with heating targets, full internal gains and no solar gains; summer 35°C with cooling targets and full gains.
- Alternatives: Existing U/ACH multipliers 1 and 0% recovery; illustrative retrofit U/ACH multipliers 0.5 and 75% mechanical recovery. Density 1.2 kg/m³; cp 1005 J/(kg·K).
Result:
Winter existing demand is 874.185 W in the living room and 482.12 W in the bedroom, totaling 1356.305 W heating with no cooling. The shared partition transfers 20 W from living to bedroom and cancels in the building net. The illustrative retrofit reduces winter heating to 448.5825 W. Summer existing sensible cooling totals 1213.0225 W; the retrofit requires 873.27125 W. These results compare authored steady assumptions, not equipment capacities or annual energy savings.
Frequently Asked Questions
Can I use this as a complete HVAC sizing calculator?
No. It explores selected steady-state sensible components and retrofit assumptions. Full design loads and equipment selection require additional climate, building, latent, solar, distribution and equipment considerations under a recognized method. It does not implement Manual J or claim MCS certification.
Why can heating and cooling both be required?
Rooms are modeled at independent targets. A warm room can lose heat through a partition while a cooler room receives more heat than it loses outdoors. The partition-only example needs 20 W heating in one room and 20 W cooling in the other, despite zero building net. A shared HVAC system may behave differently.
Does ventilation recovery reduce infiltration?
No. Recovery applies only to the entered mechanical outdoor flow. Infiltration is a separate ACH-based heat exchange. Do not enter the same air exchange in both fields. Supply temperature control, bypass behavior, moisture recovery and equipment power are not modeled.
What does a fixed-temperature boundary mean?
It represents an explicitly assumed temperature next to a surface, such as an unmodeled adjacent space. That temperature stays fixed across the outdoor sweep. It does not solve ground heat transfer or adjacent-space temperature. Shared partitions between modeled rooms should use the separate partition list.
Where should U-values and temperatures come from?
Use appropriate assembly information, measured or justified air-exchange assumptions and design conditions for your project. The examples are illustrative, not a lookup database or construction recommendation. Areas are net; enter windows separately and deduct them from walls.
What does the room balance temperature tell me?
For fixed coefficients, gains and room targets, it is the outdoor temperature at which that room has zero signed demand. The sweep includes each in-range balance point. With no outdoor-dependent heat exchange, the room can balance at every temperature or at none.
Do the retrofit results predict annual savings?
No. Multipliers are explicit what-if assumptions, and each condition is independent. There are no weather hours, occupancy schedules, energy prices, system efficiency or dynamic storage. Do not multiply one load by a year and present it as a forecast.
Are unit changes and exports exact?
The model uses exact rational SI arithmetic. Unit changes preserve quantities; displayed decimals may be rounded while the underlying value is retained until edited. A conversion that cannot fit the accepted input precision is blocked explicitly. CSV includes exact fractions, but spreadsheet software may reinterpret them on import.
Similar Calculators
Psychrometric Calculator
Compare moist-air properties and dry-air mixing on a pressure-specific temperature and humidity chart, with explicit saturation and phase limits.
HVAC Duct Pressure & Airflow Planner
Compare round and rectangular duct paths at a prescribed airflow. Visualize pressure losses, check entered pressure and velocity preferences, and export energy estimates.
Insulation Calculator & Package Cost Planner
Plan insulation quantities across zones, compare compatible package sizes and blown-material label limits, and visualize pooled purchasing savings, overage and project costs.
Tankless Water Heater Demand & Sizing Planner
Compare tankless water-heater demand across fixture schedules and seasonal inlet temperatures. Visualize peak heat, flow limits, activation gaps and exact energy costs.
Thermal Conductivity Calculator & Wall Heat Flow Planner
Find thermal conductivity from measured slab heat flow. Compare two wood-framed wall assemblies by U-factor, effective R-value, heat flow and layer temperatures.