Mini-Split Zone Capacity & Quote Planner

Enter documented loads for the same rooms, then compare two scopes using the capacity of each indoor head and its assigned outdoor unit. The worksheet shows when a proposal with enough aggregate capacity still leaves a room short. Review two quote totals and the work covered by their prices.

Matched room and outdoor ratings

Compare mini-split capacity and quotes

Presets use two published 2017 Daikin rated cooling rows at a time. Room demands and prices are illustrative. Use current documentation for the combinations in your quotes.

Rated cooling

Indoor rating point
80 °F dry · 67 °F wet
Outdoor rating point
95 °F dry · 75 °F wet

Proposal A

Rating point matches

Modeled shortfall

1.58 kBtu/h

Modeled shortfall

Room head gap
1.58 kBtu/h
Additional shared gap
0 kBtu/h

Complete quoted total

$9,200.00

Proposal B

Rating point matches

Modeled shortfall

0 kBtu/h

Entered limits cover load

Room head gap
0 kBtu/h
Additional shared gap
0 kBtu/h

Complete quoted total

$9,800.00

Only Proposal B covers the entered load within its supplied limits.

Proposal B costs $600.00 more at the entered prices.

Only Proposal B covers the entered load within its supplied limits.

Room and outdoor-unit capacity

The room bars use that indoor head’s cap. Outdoor bars use the cap shared by the rooms listed below. The same scale ends at 23.4 kBtu/h.

Proposal A

Outdoor unit 1

Daikin 3MXS24NMVJU · 09+12 · 2017 rated cooling

Demand22 kBtu/h
Entered cap21.4 kBtu/h
Outdoor cap less demand
-0.6 kBtu/h
Coverage upper bound
20.42 kBtu/h

0 kBtu/h additional shared gap

  • Living room
    Demand10.5 kBtu/h
    Entered cap8.92 kBtu/h

    1.58 kBtu/h head gap

  • Kitchen
    Demand11.5 kBtu/h
    Entered cap12.48 kBtu/h

    0 kBtu/h head gap

Proposal B

Outdoor unit 1

Daikin 3MXS24NMVJU · 12+12 · 2017 rated cooling

Demand22 kBtu/h
Entered cap23.4 kBtu/h
Outdoor cap less demand
1.4 kBtu/h
Coverage upper bound
22 kBtu/h

0 kBtu/h additional shared gap

  • Living room
    Demand10.5 kBtu/h
    Entered cap11.7 kBtu/h

    0 kBtu/h head gap

  • Kitchen
    Demand11.5 kBtu/h
    Entered cap11.7 kBtu/h

    0 kBtu/h head gap

Edit common rating point

Compare documented loads and actual equipment combinations at one common point. Check each proposal’s documents before confirming a new point.

Edit room loads

Enter the same documented simultaneous room loads for both proposals.

Room 1

Room 2

Edit Proposal A capacities

Enter the indoor and outdoor figures for each actual combination at this point.

Outdoor unit 1

Living room

Kitchen

Confirm that the supplied indoor and outdoor data use the current mode, temperatures and capacity basis.

Rating point matches

Edit Proposal B capacities

Enter the indoor and outdoor figures for each actual combination at this point.

Outdoor unit 1

Living room

Kitchen

Confirm that the supplied indoor and outdoor data use the current mode, temperatures and capacity basis.

Rating point matches

Written quote scope

Compare the costs your quotes cover. Unknown prices stay visible.

Entered quote lines and price coverage
ScopeProposal AProposal B
Equipment$5,500.00$6,200.00
Installation labor$3,000.00$3,100.00
Electrical$500.00$500.00
Other quoted work$200.00Included
Complete quote$9,200.00$9,800.00
Edit Proposal A quote

An included line adds no charge. Choose Unpriced when its cost is unsupported by the quote.

Edit Proposal B quote

An included line adds no charge. Choose Unpriced when its cost is unsupported by the quote.

Capacity ledger and export

Show room and group figures

In kBtu/h. The group gap combines head gaps and any additional shared gap. Room rows show their own head gap.

Proposal A

Proposal A · Outdoor unit 1
LoadNeedCapGap
Group2221.41.58
Living room10.58.921.58
Kitchen11.512.480

Proposal B

Proposal B · Outdoor unit 1
LoadNeedCapGap
Group2223.40
Living room10.511.70
Kitchen11.511.70
Download mini-split comparison CSV
Show selectable CSV text

How to use this calculator

  1. Enter the common heating or cooling point, rated or maximum basis and applicable indoor and outdoor temperatures.
  2. Add the rooms and enter their documented loads at that point.
  3. For each proposal, enter the outdoor-unit count and capacities. Assign each room to its outdoor unit and enter its actual matched head capacity.
  4. Confirm that each source record matches the current point. Compare room gaps, shared gaps and the coverage bound. Enter the rates and coverage stated in each written quote.
  5. Download the rating point, matched capacities, room assignments and quote lines as CSV.

The Formula

The mathematical logic powering this calculation is:

The worksheet compares one documented heating or cooling point. Enter a common rated or maximum basis and indoor/outdoor dry-bulb values. Add wet-bulb values when the compared records use them. Every head and outdoor-unit capacity must come from its applicable actual combination at the same point and basis. Confirm the match for each proposal. Changing an active point field invalidates confirmations tied to a different point. A dry-only record omits both wet-bulb fields and ignores their inactive drafts.

Each room has a documented demand D and an indoor-head capacity C at that point. The room deficit is max(0, D − C). The largest room contribution to this modeled demand is min(D, C). For one outdoor unit, add these usable room contributions into H. If its entered concurrent cap G is below H, the additional shared shortfall equals H − G. The group’s coverage upper bound is min(H, G). Total modeled shortfall is the sum of head deficits and additional shared deficits. An outdoor group’s raw capacity less total room demand is reported separately. A surplus in one room or group cannot cover another room’s head deficit or the capacity of another group.

The method compares numerical ceilings supplied by the user. A shared shortfall remains assigned to the outdoor group because actual indoor distribution and controls are unknown. Satisfying the worksheet ceilings establishes numeric coverage under the assumptions only. The model does not estimate physical room loads, actual air delivery, cycling, equipment compatibility, comfort, temperature interpolation, site suitability, refrigerant work, efficiency or regulatory requirements.

Quotes are entered in USD as equipment, installation labor, electrical and other quoted work. A priced line adds its own amount. A confirmed included line has no incremental amount because it is contained elsewhere in that quote. An unpriced line keeps the known subtotal visible and leaves the complete total unavailable. At least one explicit price is required for a complete total. The difference compares entered complete totals and assumes the buyer has checked comparable written scope. Tax or discounts may be included in the relevant entered price. No extra rates or charges are inferred.

Enter 1–6 rooms and 1–3 outdoor units per proposal. Capacities and room loads are 0–1,000 kBtu/h with three decimals, stored as whole Btu/h. Temperatures are −40°F through 140°F with one decimal, with wet bulb at or below dry bulb. Prices are $0–$10,000,000 per line with cents. Labels use 1–44 characters for rooms and groups and 1–100 for an outdoor-unit source.

Worked Example

If you input:

  • Rated cooling point: Indoors 80°F dry bulb, 67°F wet bulb. Outdoors 95°F dry bulb, 75°F wet bulb.
  • Documented room loads: Illustrative 10.50 and 11.50 kBtu/h. Total 22 kBtu/h.
  • Proposal A: Daikin 09+12 combination. Heads 8.92 and 12.48 kBtu/h, outdoor rating 21.40 kBtu/h, illustrative total $9,200.
  • Proposal B: Daikin 12+12 combination. Heads 11.70 and 11.70 kBtu/h, outdoor rating 23.40 kBtu/h, illustrative total $9,800.

Result:

Proposal A’s first room has a 1.58 kBtu/h head gap. A's outdoor rating is 0.60 kBtu/h below total room demand, but its usable room output is at most 20.42 kBtu/h. The modeled shortfall is 1.58 kBtu/h. Proposal B has no numerical gap under the supplied ceilings and the entered quote is $600 higher.

Frequently Asked Questions

Why can enough outdoor capacity still leave a room short?

The group total can exceed combined demand while a specific room’s indoor head limits its contribution. That room’s head gap stays visible even when the group has positive raw headroom.

When does a shared gap appear?

If the sum of usable room contributions exceeds the group’s concurrent outdoor capacity, the excess is a shared gap. The worksheet keeps it at group level because input ratings alone do not determine its distribution among rooms.

Can I enter the nominal capacity printed in a unit model number?

Use the documented capability for the actual indoor–outdoor combination at your stated point and basis. The same heads can have different capacities in a different combination. Nominal class does not establish available room output.

Can I compare a rated source with a maximum source?

Use one shared basis for both proposals and confirm that each source applies at that basis. Changing the basis or temperature point requires confirmation against the applicable documentation again.

Which room load should I enter?

Enter the documented heating or cooling demand for each room at the common conditions. The comparison does not estimate these loads from floor area or infer diversification.

How do I include optional or missing quote work?

Use Included when the quote confirms there is no separate charge. Use Unpriced when its cost is unknown and still needs confirmation. That proposal keeps a known subtotal and waits for a complete price.

Does clearing the entered limits mean a proposal will heat or cool the rooms?

It means the documented numerical ceilings can cover the entered demand in this model. A qualified project review considers installation constraints, equipment pairing, control behavior, actual distribution and operation.