Greenhouse Heating Calculator & Overnight Capacity

Start with measured gable geometry, then compare roof and wall transmission and air exchange under two greenhouse envelopes. Schedule up to three outdoor-temperature blocks and identify exactly where a supplied heat output falls short in this steady-state model.

Greenhouse planning

Compare overnight heating demand

Use the same gable envelope and night profile to compare two cover assemblies and a recorded heat output.

Only assembly B covers every entered heating block.

Gable envelope and heat output
Cover assemblies and overnight blocks

Use transmission-only U-values because air change is entered separately. Set a block to zero hours when it is outside the night you are comparing.

Assembly A
Assembly B
Early block
Middle block
Late block
Assembly A peak load
98,680 BTU/h
9 h of modeled shortfall
Assembly B peak load
63,160 BTU/h
0 h of modeled shortfall

Gable profile and surfaces

Roof area
1,000 ft²
Wall and gable ends
1,110 ft²
Enclosed volume
9,400 ft³
8 ft eaves, +7.5 ft rise · 40 ft long

Heating demand through the night

BTU/h by elapsed hour. The length of each step shows its entered duration.

Early · 36°F · 3 h
Middle · 28°F · 4 h
Late · 20°F · 5 h
Solid teal is Assembly A and dashed blue is Assembly B. The dashed brown line is 75,000 BTU/h delivered.

Overnight energy reconciliation

Assembly A
Demand · 986,800 BTU
Unmet · 134,176 BTU
Peak headroom · -23,680 BTU/h
Assembly B
Demand · 631,600 BTU
Unmet · 0 BTU
Peak headroom · 11,840 BTU/h
Exact block ledger and CSV

Early block · 3 h

Assembly A
59208 BTU/h
Assembly B
37896 BTU/h

Middle block · 4 h

Assembly A
78944 BTU/h
Assembly B
50528 BTU/h

Late block · 5 h

Assembly A
98680 BTU/h
Assembly B
63160 BTU/h

How to use this calculator

  1. Measure the rectangular footprint, eave height and ridge rise of the same greenhouse for both envelopes.
  2. Enter surface-only roof and wall U-values, and separate air changes per hour for each assembly.
  3. Set the indoor target and enter the heater output actually delivered to the greenhouse under the conditions you plan to compare.
  4. Enter the outdoor temperature and duration of up to three consecutive blocks. Use zero hours for a block you are leaving out.
  5. Read the capacity line, peak load and total shortfall, then inspect the geometry and CSV details.

The Formula

The mathematical logic powering this calculation is:

Use the outside envelope of one freestanding rectangular greenhouse with a symmetric gable. Let L be its length, W its span, H its eave height and G the rise from eave to ridge. The rafter length is √[(W/2)² + G²]. The two sloping roof planes total 2 × L × rafter length. Four rectangular walls plus two triangular gable ends have area 2 × (L + W) × H + W × G. The enclosed air volume is L × W × (H + G/2). Enter a whole-wall effective conductance for the vertical envelope if wall sections have different materials.

In BTU/(h·°F), the roof and wall coefficients are area × U. The air coefficient is 0.02 × enclosed ft³ × entered air changes per hour, using the University of Georgia empirical model. The U-values should cover surface transmission alone because air exchange is already counted separately. Enter comparable values for the two assemblies, including any effective values you have established for a thermal screen or a different glazing.

For a block, the target-to-outdoor temperature difference is clamped at zero. Multiply the sum of the three coefficients by that difference to obtain a steady-state heating demand in BTU/h. The peak is the highest demand among nonzero-duration blocks. Heating headroom equals the entered delivered output less the modeled demand. Demand energy is the sum of demand × duration. Unmet energy sums max(0, demand − delivered output) × duration. The shortfall hours are the sum of whole block durations whose steady demand exceeds the supplied output. Equality is a fit within this comparison.

The worksheet excludes soil and foundation heat flow, thermal storage, wind changes within a block, light and equipment gains, condensation, humidity control, door cycles and equipment efficiency, derating or fuel use. Heat deficit reports an energy imbalance for the entered setpoint throughout a block. It does not predict the greenhouse temperature after a shortfall. Use delivered heat, rather than fuel or electrical input, and check any actual selection against local conditions and the equipment documentation.

Enter feet, °F, BTU/h and hours to four decimal places. Dimensions span 0.0001 to 10,000 ft. Temperatures span −100 to 150°F. U-values and air changes each span zero to 30 in their respective units. Delivered heat spans zero to 100,000,000 BTU/h. Enter zero hours for an inactive block, with more than zero hours and up to 24 hours across the night.

Worked Example

If you input:

  • Gable greenhouse: 40 × 20 ft footprint, 8 ft eaves and 7.5 ft ridge rise
  • Heating: 60°F target and 75,000 BTU/h delivered
  • Overnight blocks: 36°F for 3 h, 28°F for 4 h and 20°F for 5 h
  • Assembly A: Roof U 0.90, wall U 1.20, 1.25 air changes/h
  • Assembly B: Roof U 0.55, wall U 0.80, 0.75 air changes/h

Result:

The roof area is 1,000 ft², wall area 1,110 ft² and volume 9,400 ft³. At 20°F outside, Assembly A needs 98,680 BTU/h and Assembly B needs 63,160 BTU/h. At the entered output, A falls short for 9 h and B covers all 12 h in the model.

Frequently Asked Questions

Can I use this for a hoop house or a lean-to?

The surface and volume model uses one symmetrical gable roof with vertical walls. Curved frames, attached sides, internal partitions and shed roofs need a model for their own geometry.

Where should I enter a thermal curtain?

Use a published or measured effective U-value for the complete roof or wall assembly under its operating conditions. Assembly B can represent that estimate. A curtain may also change air exchange, which is a separate authored input.

Why are there both air changes and a roof U-value?

A roof U-value describes heat transmission through surfaces. Air changes estimate heat carried out as inside air leaks or exchanges with outside air. Enter surface-only U-values to keep those mechanisms separate.

What do shortfall hours mean?

These are the durations of blocks whose steady-state heating load exceeds the recorded delivered output. The result cannot predict how fast the air temperature would fall.

What if the outdoors is warmer than the target?

That block has zero calculated heating demand. This worksheet has no cooling or crop humidity model.

How is BTU different from BTU/h?

BTU/h is a rate, such as a heater’s delivered capacity. Multiplying a rate by a block’s hours gives energy in BTU.

Similar Calculators