Garage Heater Size & Door Recovery Calculator

Model the changing garage temperature between measured door events using an entered effective heat capacity and background losses. See each heater’s deadline margin, the first time it reaches the target and how a door opening changes the recovery curve.

Timed sensible heat balance

Compare garage heating across door openings

Edit temperatures and delivered output
Edit heating blocks and door events
Block 1
Block 2
Block 3
Both heaters meet the modeled deadline target.

Minimum delivered output

4,300 W

14,672.21 Btu/h

55 °F by 150 min

Heater A · 4,300 W delivered

55 °F at deadline

0 °F vs target · 8,600 Wh delivered heat

First target at 150 min

Heater B · 5,000 W delivered

58.5 °F at deadline

3.5 °F vs target · 10,000 Wh delivered heat

First target at 130 min

Inspect the recovery timeline

Modeled temperature (°F)

  • Heater A
  • Heater B
  • Target
  • Door loss

Block 2 · 60 to 90 min

Heating paused · 400 Wh background loss

2 °F door drop at block end · 800 Wh equivalent

Heater A · 49.25 to 48.25 °F before door loss

46.25 °F after the block · 0 Wh delivered

Heater B · 51 to 50 °F before door loss

48 °F after the block · 0 Wh delivered

Review exact heat and temperature ledger
Recovery heat and door-loss ledger
HeaterBlockStart (°F)Before door (°F)Final (°F)Delivered (Wh)Net change (Wh)
A14049.2549.254,3003,700
A249.2548.2546.250-1,200
A346.2555554,3003,500
B14051515,0004,400
B25150480-1,200
B34858.558.55,0004,200

How to use this calculator

  1. Enter a starting temperature, deadline target and a measured or documented effective storage value.
  2. Enter the useful heat delivered into the same garage by both options. Use heat output as delivered rather than fuel or appliance power input.
  3. Enter consecutive blocks and their measured or estimated background heat losses. Mark powered or paused periods and enter any additional observed loss when the door closes at a block boundary.
  4. Compare the deadline temperatures and minimum constant delivered output. Inspect the timeline before and after each door event.
  5. Download the exact heat and temperature ledger.

The Formula

The mathematical logic powering this calculation is:

Use one effective sensible heat capacity in Wh/°F for a comparable recorded garage condition. Each block has a constant background loss in W and available heating either throughout the interval or paused. Net stored Wh within the block equals the delivered watts minus background loss, multiplied by duration ÷ 60. Divide by heat capacity to convert net Wh to the block temperature change. Apply the entered additional door-opening temperature drop once at the end of that block. Use a drop that excludes any loss already represented by the background term.
Both options use the same block durations, door events and starting temperature. The first target encounter can occur inside a block or just before its door loss. Interpolate between the block's start and pre-door temperature to find that time. The deadline is the end of the last block, after its door opening when entered. Only the final temperature determines deadline coverage. Equality qualifies.
To calculate the minimum delivered output, add background loss and equivalent door-event heat loss to the required stored energy, capacity × (target − start). Divide a positive result by the total heating-enabled hours. If the result is zero or lower, no heating is needed to meet the modeled deadline. A positive requirement with zero enabled time cannot be met by adding power. Convert W to Btu_IT/h using 3,600 J/h per watt and 1,055.05585262 J per Btu_IT.
Enter 1–5 consecutive blocks of 0.001–1,440 min, temperatures −100 to 200 °F, heat capacity 0.001–1,000,000 Wh/°F, delivered output or background loss of 0–1,000,000 W, and 0–100 °F door loss per block. Numbers support up to three decimals. Comparisons and the CSV use exact rational quantities.
This one-temperature model requires entered losses, capacity and delivered output for relevant observed conditions. It does not infer building losses from area or weather, or model temperature-dependent leakage, thermostat cycling, ongoing open-door exchange, combustion, ventilation safety, electrical supply or equipment suitability.

Worked Example

If you input:

  • Garage: 400 Wh/°F, from 40 °F to a 55 °F deadline
  • Blocks: 60 min on at 600 W loss, 30 min paused at 800 W loss with a 2 °F door drop, 60 min on at 800 W loss
  • Delivered heat: Heater A 4,300 W and Heater B 5,000 W

Result:

At 150 min, Heater A reaches exactly 55 °F and Heater B reaches 58.5 °F. Heater B first reaches 55 °F at 130 min. Increasing the door loss to 2.001 °F raises minimum delivered output to 4,300.2 W, and only B meets the deadline target.

Frequently Asked Questions

Why can a heater reach the target earlier yet finish below it?

A subsequent paused block or door-opening step can lower the garage temperature. The deadline uses the recorded sequence through the last block, after its final door event.

Does the minimum required output use the duration of every block?

All blocks can lose heat. Only enabled blocks receive heat, so only their accumulated duration divides the required energy.

How should door loss and background loss be separated?

Use background loss for steady transfer over the block, and a separate additional measured temperature drop for the door event. Keep both quantities on the same overall garage heat-capacity basis.

Does the chart model thermostat cycling?

A heater delivers the same entered output during every enabled block. The chart continues through the deadline to show the resulting temperature under that schedule.