Thermal Conductivity Calculator & Wall Heat Flow Planner
Use measured specimen thickness, area, surface temperatures and net conducted power to infer conductivity. In the wall worksheet, compare two assemblies with the same area and temperatures. Add common layers and enter a framing area share to see how much of the modeled heat passes through the framing.
Compare conductivity and wall heat flow
See how framing, cavity materials and continuous layers affect heat flow and interface temperatures.
Shared boundaries
Use surface temperatures, or include air films as fixed resistances and use the corresponding air temperatures. Intended for independent wood-framed paths.
Design A assembly
Inside layers (1)
Outside layers (1)
Design B assembly
Inside layers (1)
Outside layers (2)
Design B transfers 112.5 W less.
Heat flow and path shares
Positive flow goes from inside to outside. Path conductance shares also describe heat shares when temperatures differ.
Design A
300 W
- U-factor
- 0.5 W/(m²·K)
- Equivalent R
- 2 m²·K/W
- US R
- 11.3565 h·ft²·°F/Btu
Framing share of wall area25%
Framing share of conductance50%
Design B
187.5 W
- U-factor
- 0.3125 W/(m²·K)
- Equivalent R
- 3.2 m²·K/W
- US R
- 18.1704 h·ft²·°F/Btu
Framing share of wall area25%
Framing share of conductance40%
Temperature through the assembly
Both plots share the same distance and temperature scales. A vertical step represents resistance at zero entered thickness.
Open interface and heat ledger
Design A · Cavity
30 m² · 150 W signed flow
- Interior board
- 20 mm · 19 °C · added R 0.2 m²·K/W
- Cavity core
- 120 mm · 6.5 °C · added R 2.5 m²·K/W
- Exterior board
- 135 mm · 5 °C · added R 0.3 m²·K/W
Design A · Framing
10 m² · 150 W signed flow
- Interior board
- 20 mm · 17 °C · added R 0.2 m²·K/W
- Framing core
- 120 mm · 9.5 °C · added R 0.5 m²·K/W
- Exterior board
- 135 mm · 5 °C · added R 0.3 m²·K/W
Design B · Cavity
30 m² · 112.5 W signed flow
- Interior board
- 20 mm · 19.25 °C · added R 0.2 m²·K/W
- Cavity core
- 120 mm · 9.875 °C · added R 2.5 m²·K/W
- Exterior board
- 135 mm · 8.75 °C · added R 0.3 m²·K/W
- Continuous insulation
- 175 mm · 5 °C · added R 1 m²·K/W
Design B · Framing
10 m² · 75 W signed flow
- Interior board
- 20 mm · 18.5 °C · added R 0.2 m²·K/W
- Framing core
- 120 mm · 14.75 °C · added R 0.5 m²·K/W
- Exterior board
- 135 mm · 12.5 °C · added R 0.3 m²·K/W
- Continuous insulation
- 175 mm · 5 °C · added R 1 m²·K/W
Infer conductivity from a measured specimen
Use an approximately steady, uniform slab and heat flow measured through that slab. Enter the two measured surface temperatures.
Inferred k 0.04 W/(m·K)
Export calculated quantities
Show CSV text
How to use this calculator
- Enter the wall area and the same indoor and outdoor boundary temperatures for both designs.
- Enter each core's thickness, wood framing area share and cavity and framing conductivity.
- Open the inside and outside layer editors. List each layer in order from the inside boundary toward the outside boundary. Choose solid conductivity or a fixed areal resistance.
- Compare signed watts, effective U and R, and the path shares. Open the interface ledger to read layer locations alongside the plotted profile.
- For a uniform slab, open the specimen worksheet and enter measured area, depth, surface temperatures and net conducted power. Apply the inferred value to a cavity only if it describes that material.
- Download the calculated assembly or opened specimen records as CSV.
The Formula
The mathematical logic powering this calculation is:
Heat conduction through a uniform slab follows Q = k × A × ΔT / d, with rate Q in watts, k in W/(m·K), area A in square metres, temperature difference ΔT in kelvin, and depth d in metres. In the measurement worksheet, enter positive measured conducted watts, thickness and area, and two distinct surface temperatures. Rearrange the equation to k = |Q| × d / (A × |ΔT|). Use net measured conduction through the specimen. Heater output and surface temperatures measured away from the slab cannot establish that quantity on their own. Copying a supported result to a design keeps the exact fraction.
For each common solid layer and each path's core, divide its depth in metres by its conductivity to get areal resistance in m²·K/W. Fixed-resistance layers take the entered value directly. Add the inside, core and outside resistances separately for the cavity and framing. Each path's conductance in W/K is its area divided by that path's resistance. Add the two conductances and divide by the total area for equivalent U-factor. Its reciprocal is equivalent areal R. Convert SI R to US R using the exact international foot, Fahrenheit temperature interval, hour and International Table Btu.
Multiply each path's conductance by the signed inside-minus-outside temperature difference for its heat flow. Positive is outward. The framing share of conductance is the framing conductance divided by the combined conductance, and equals its share of heat magnitude when the boundaries differ. Equal boundaries yield zero heat flow and retain the same U and R. For path temperatures, divide the temperature difference by the path resistance to get flux per square metre. Subtract flux times each layer's resistance from the prior temperature. The plot shows a vertical step when a fixed resistance has zero entered depth. A path with zero area contributes zero heat and the ledger labels its temperatures as hypothetical. The comparison uses the magnitudes of flows for the same boundary temperatures.
Inputs support 0.000001–1,000,000 m² area, −200 to 300 °C temperature, 0–100% framing, 0.000001–100,000 mm positive thickness, 0.000001–5,000 W/(m·K) conductivity, and 0.000001–100 m²·K/W fixed resistance. Fixed layers allow zero thickness. Use up to three common layers on each face. Measured conducted power accepts 0.000001–100,000,000 W. Draft amounts accept up to six decimal places or exact fractions. The limits are arithmetic bounds. This steady one-dimensional model assumes constant conductivities, independent wood-framed paths and uniform boundary temperatures. Add known film resistances only when using corresponding air temperatures. Detailed two-dimensional junctions, metal framing, air leakage, thermal storage, moisture, annual energy, structural suitability and code compliance require other methods.Worked Example
If you input:
- Shared boundaries: 40 m². Inside 20 °C and outside 5 °C.
- Design A: 25% framing, 100 mm core, and 0.04/0.2 W/(m·K) cavity/framing conductivity, with common R of 0.5 m²·K/W.
- Design B: Same wall with another 40 mm of continuous insulation at 0.04 W/(m·K).
Result:
Design A transfers 300 W outward at U 0.5 W/(m²·K). Framing carries 50% of the modeled heat through 25% of the wall. Design B transfers 187.5 W at U 0.3125 W/(m²·K), which is 112.5 W less. In the separate specimen example, 4 W through 50 mm and 0.25 m² across 20 °C gives 0.04 W/(m·K).
Frequently Asked Questions
What is the difference between thermal conductivity and a wall U-factor?
Thermal conductivity describes the material. The wall U-factor represents the heat transfer rate per square metre and kelvin across the entire modeled assembly, including its layers and active paths.
Why is the effective R-value lower than the cavity path R?
An active framing path can have lower resistance and carry a greater share of heat than its share of wall area. The calculator combines the paths by conductance.
Should I enter wall surface or room air temperatures?
Use the temperatures at your modeled boundaries. If you use ambient air temperatures, include your known surface film resistances. Enter measured material surface temperatures for conductivity inference.
Can the calculated interface temperatures predict condensation?
The profile models dry, steady conduction for the entered assembly. Moisture, vapor transport and transient exposure require additional inputs and a separate analysis.
Can I use the equivalent U-factor for a room heat comparison?
You can enter it in the Room Heat Balance Explorer for the same net area and compatible boundaries, after checking that the assembly assumptions fit your project.
Similar Calculators
Room Heat Loss & Retrofit Calculator
Explore room heat loss and sensible cooling, compare envelope and ventilation retrofits, and visualize heat flows and outdoor-temperature sensitivity with exact CSV ledgers.
Insulation Calculator & Package Cost Planner
Plan insulation quantities across zones, compare compatible package sizes and blown-material label limits, and visualize pooled purchasing savings, overage and project costs.
Spray Foam Thickness, Yield & Quote Planner
Compare spray foam quotes and proposed depth by zone. Estimate board feet, check entered kit yield ranges and separate missing installation charges.
Window Replacement Cost & Quote Calculator
Compare window replacement quotes by opening, installation, allowances and rebates. Explore optional heating savings, payback and net present value with charts and CSV.