12V DC Shared Feeder Wire Sizing Calculator

Check two simultaneous operating measurements on one shared 12V feeder. Combine documented cable resistance, installed loop length and price to test every mixed-cable arrangement against your entered terminal voltage and current references.

Shared feeder worksheet

Compare cable mixes for a shared 12 V feeder

One cable mix has the lowest qualifying cost.

Cable mix and operating margin

15 of 27 mixes meet all entered limits.

$45.00 lowest qualifying wire cost · B / B / A

Snapshot shown

Mix order is feeder, branch 1, branch 2. Automatic shows the cheapest qualifying mix or previews C / C / C when all miss.

B / B / A · Meets all entered limits · $45.00

Across both snapshots · 0.03 V lowest voltage margin · 1 A lowest current margin

Edit cable, path and load inputs

The sample uses invented cable data. Use the resistance at your operating condition and a current reference documented for each candidate and each intended placement.

Supply and return paths

Loop length is supply plus return for each segment.

Shared feeder

Branch 1

Branch 2

Three cable candidates

Cable A

Cable B

Cable C

Two simultaneous snapshots

Use loaded voltage at the feeder origin with the two currents for that same snapshot.

Lower load

Higher load

Voltage through the shared feeder

Both branches start at the same split voltage. Short marks near the endpoints show their entered minimums.

Voltage from source to split and two loadsHigher load. Source 12.2 V, split 11.71 V, branch 1 11.47 V and branch 2 11.53 V.12.2 V11.4 VSourceSplitLoads
  • Solid · Branch 1
  • Dashed · Branch 2
Source
12.2 V
At split
11.71 V
Branch 1
11.47 V
Branch 2
11.53 V

Resistive path loss in this snapshot · 4.93 W

Review candidate and circuit ledgers
Higher load · selected mix B / B / A
SegmentCurrent (A)Drop (V)Current margin (A)
Shared feeder70.491
Branch 140.244
Branch 230.182
All 27 mixes in feeder, branch 1, branch 2 order
MixWire costWorst voltage marginResult
A / A / A$25.00-0.59 VVoltage and current limits missed
A / A / B$30.00-0.59 VVoltage and current limits missed
A / A / C$40.00-0.59 VVoltage and current limits missed
A / B / A$35.00-0.39 VVoltage and current limits missed
A / B / B$40.00-0.35 VVoltage and current limits missed
A / B / C$50.00-0.35 VVoltage and current limits missed
A / C / A$55.00-0.39 VVoltage and current limits missed
A / C / B$60.00-0.3 VVoltage and current limits missed
A / C / C$70.00-0.255 VVoltage and current limits missed
B / A / A$35.00-0.17 VVoltage limit missed
B / A / B$40.00-0.17 VVoltage limit missed
B / A / C$50.00-0.17 VVoltage limit missed
B / B / A$45.000.03 VMeets all entered limits
B / B / B$50.000.07 VMeets all entered limits
B / B / C$60.000.07 VMeets all entered limits
B / C / A$65.000.03 VMeets all entered limits
B / C / B$70.000.12 VMeets all entered limits
B / C / C$80.000.165 VMeets all entered limits
C / A / A$55.000.04 VMeets all entered limits
C / A / B$60.000.04 VMeets all entered limits
C / A / C$70.000.04 VMeets all entered limits
C / B / A$65.000.24 VMeets all entered limits
C / B / B$70.000.28 VMeets all entered limits
C / B / C$80.000.28 VMeets all entered limits
C / C / A$85.000.24 VMeets all entered limits
C / C / B$90.000.33 VMeets all entered limits
C / C / C$100.000.375 VMeets all entered limits

Currents are fixed per snapshot. Check actual loads and installation limits separately, including protection, temperature and any startup behavior.

How to use this calculator

  1. Load the example and open Edit cable, path and load inputs. Enter total supply-plus-return length and fixed resistance for the common feeder and each branch.
  2. Pick three documented cable candidates. Enter each operating resistance, applicable current reference and price per foot.
  3. Enter two snapshots. For each use the voltage at the start of the shared feeder and the simultaneously measured current at both loads.
  4. Enter each load's minimum voltage. Compare the qualifying mixes, then choose a mix and snapshot to inspect the voltage profile.
  5. Open the circuit and candidate ledger for exact segment values or download all 27 combinations.

The Formula

The mathematical logic powering this calculation is:

Use a two-wire DC feeder with one shared segment and two branches. For each segment use the complete supply-and-return length L and one-conductor resistance r in Ω per 1,000 ft. That unit is numerically mΩ per foot. Loop resistance is r × L plus the entered fixed resistance in mΩ. Enter any characterized connector or common return loss once in its proper segment. The two conductors in each modeled segment use the same cable data.

In each measured snapshot, the feeder carries branch currents I₁ + I₂. Branch currents are independent inputs from that same operating point. Convert the product of amperes and milliohms to volts by dividing by 1,000. Subtract feeder drop from loaded source voltage to find split voltage, then subtract each branch drop from that voltage. Sum current times segment drop for total resistive path dissipation.

Evaluate all 3 × 3 × 3 cable combinations. Both branch voltages must reach their entered minima and all segment currents must be at or below the corresponding entered current references in both snapshots. Equality meets an entered mathematical limit. The common run carries both currents together. Enter a reference valid for every intended placement of that cable or compare each placement separately.

Wire cost is the sum of each entered loop length times the candidate USD/ft rate. Calculate in exact fractions and retain every equal-cost qualifying mix. An empty qualifying set remains visible; Automatic previews cable C in all positions when no mix qualifies. Export all modeled quantities and case margins as exact fractions.

Each measured source supports more than 0 through 60 V, branch currents 0–1,000 A, load minima 0–60 V, each direct loop 0–10,000 ft, fixed resistance up to 100,000 mΩ, cable resistance more than 0 through 1,000 Ω/1,000 ft, current references more than 0 through 1,000 A, and price up to 10,000 USD/ft. Inputs accept up to eight decimal places. These are computational bounds.

Source voltage is already loaded at the start of the common feeder. Real supply sag, changing loads, transients, temperature, insulation, installation details and protection can alter behavior and require separate assessment. Negative calculated terminal voltage indicates the fixed-current model cannot sustain the entered case. The examples are illustrative and do not supply cable ampacity, protection settings or electrical approval.

Worked Example

If you input:

  • Shared feeder and branches: 20, 20 and 10 ft loops respectively, with 10 mΩ additional resistance in the feeder.
  • Cable A / B / C: 6 / 3 / 1.5 Ω per 1,000 ft. Current references 5 / 8 / 12 A. Prices $0.50 / $1 / $2 per ft. Illustrative values.
  • Lower and higher loads: 12.6 V with 2 and 2 A, then 12.2 V with 4 and 3 A. Load minima 11.4 and 11.5 V.

Result:

The only lowest-cost mix is B / B / A at $45. At the higher load, the shared split is 11.71 V and the branch terminals are 11.47 V and 11.53 V.

Frequently Asked Questions

Why does the other branch change voltage at my load?

Both branches draw current through the shared feeder. More current in one branch increases shared drop, so both branches start from a lower split voltage.

What length goes into the model?

Enter the complete supply and return length for each segment. Use a fixed resistance for modeled in-line connections whose resistance you know.

Why enter a loaded supply voltage?

Enter the reading at the start of the feeder while the two loads draw the entered currents. This keeps measured battery or regulator sag in the source reading without counting downstream losses twice.

What if cheaper cable works on one branch only?

The worksheet independently chooses one of the three options for the feeder and each branch. The cheapest qualifying combination can mix all sizes.

Why does no mix qualify?

Inspect the voltage and current margins for each combination. If available source voltage is below a load's minimum, changing resistive cable alone cannot raise it.

Where do cable resistance and current references come from?

Use documented data for the actual cable and expected operating condition. Enter the current reference for the intended placement separately. The result checks those supplied values.

Similar Calculators