Wire Weight & Reel Inventory Calculator
Estimate remaining wire on two reels from loaded weight and empty tare. Compare job coverage when reels can be pooled or the run needs one continuous length. Check both tags against a common mass per meter.
Weigh reels and check a planned wire run
Compare the remaining length on two reels of the same wire against the job and its reserve.
Job coverage
Required 310 m with reserve · predicted wire mass 15.5 to 17.05 kg
Wire mass basis · 50 to 55 g/m
Pooled stock
310 to 353 m
Covered at every entered bound
One continuous reel
200 to 228 m
Short at every entered bound
Mass per length consistent with entered tags · 51.1627907 to 52.08333333 g/m
Stock estimates use weighing and the selected mass basis. Tags are checked separately.
Edit wire, scale and job inputs
Reel A
200 to 228 m
Weighed wire · 11 to 11.4 kg
Tag fits this weighing alone
Tag-predicted wire · 10.75 to 11.825 kg
Reel B
110 to 125 m
Weighed wire · 6.05 to 6.25 kg
Tag fits this weighing alone
Tag-predicted wire · 6 to 6.6 kg
Remaining length and requested run
The shaded intervals span the weighing-based low and high lengths. The dashed line marks the requested run with reserve.
Open dot · least length under the entered bounds.
Review weighing ledger and exact CSV
| Reel | Gross | Tare | Net | Remaining |
|---|---|---|---|---|
| A | 13.1 to 13.3 kg | 1.9 to 2.1 kg | 11 to 11.4 kg | 200 to 228 m |
| B | 8.1 to 8.2 kg | 1.95 to 2.05 kg | 6.05 to 6.25 kg | 110 to 125 m |
How to use this calculator
- Use two reels of the same wire and one shared catalog or solid circular mass basis.
- Enter loaded and empty reel readings with their separate scale error bounds. Include comparable hardware in the tare.
- Enter a documented current length for each reel when available. Leave the tag blank if only an original ship length is known.
- Enter the intended run length and reserve. Compare pooled stock with the longest possible continuous run.
- Resolve tag disagreements with actual part and reel data. Open the ledger to download exact mass and length bounds.
The Formula
The mathematical logic powering this calculation is:
Use one cable construction on both reels. Enter catalog mass-per-length bounds in g/m. The numbers for kg/km are identical. Choose solid round geometry for a circular solid core and, optionally, a concentric jacket. The modeled linear mass is π/4 times [D²ρ_core + ((D + 2t)² − D²)ρ_jacket] in g/m, for core diameter D and radial jacket thickness t in mm and densities in g/cm³. The factor comes from one meter of an area measured in mm² having the same numerical volume in cm³. Use catalog mass for stranded or complex cable.
Calculate the raw net mass interval using loaded gross minus empty tare. The minimum uses the lowest gross and highest tare. The maximum uses highest gross and lowest tare. An entirely negative interval is inconsistent. If it straddles zero, intersect it with the physically possible nonnegative wire mass range.
With density per length μ in g/m and measured net wire mass M in kg, remaining length in meters is 1,000 M ÷ μ. Use the heavy per-meter bound and light mass for the lower length, and the light per-meter bound and heavy mass for the upper. Add both length bounds to compare pooled stock. When the run must remain continuous, take the largest lower bound and largest upper bound of the two reels. This assumes that each reel's wire is one unbroken length.
The job target is base run × (1 + reserve / 100). A lower estimate that equals the target covers the entered bounds. When the upper estimate is below the target, the reels are short. Otherwise coverage depends on actual stock. Multiplying target length by each linear mass bound gives the expected net wire mass for the job.
A positive tag length L implies a mass per length of 1,000 M ÷ L across the scale range. Intersect the tag-derived intervals of both reels with the selected catalog or geometry range. A zero tag is compatible only if the net mass range includes zero. Two tags can each fit their own reel but disagree about the common wire mass. The weighing-based estimates do not narrow using unverified tags.
Lengths and tag values accept 0–1,000,000 m, gross and tare readings and errors accept 0–100,000 kg, reserve accepts 0–1,000%, linear mass accepts a positive value up to 10,000,000 g/m, geometry diameters and thicknesses accept up to 1,000 mm and positive active densities accept through 100 g/cm³. Use up to eight decimal places. Geometry uses π rounded to 20 fractional digits. With that constant, the worksheet keeps exact fractions for bounds and exports. The interval models entered measurement errors independently. Use documented limits for the actual wire, scale, reel hardware and winding state.Worked Example
If you input:
- Same wire: 50 to 55 g/m, with a 310 m job target including reserve.
- Reel A: 13.2 kg ±0.1 loaded, 2 kg ±0.1 empty tare and 215 m tag.
- Reel B: 8.15 kg ±0.05 loaded, 2 kg ±0.05 empty tare and 120 m tag.
Result:
Reel A has 200–228 m and B has 110–125 m. Pooled stock has 310–353 m and covers the stated job. One reel cannot supply an uncut 310 m run.
Frequently Asked Questions
Can I enter a supplier figure in kilograms per kilometer?
Yes. One kilogram per kilometer equals one gram per meter, so enter the same number in the catalog fields.
Does wire weight include the reel or packaging?
Use plain wire mass including any insulation for the mass-per-length input. Subtract an empty reel tare that includes comparable hardware.
When should I use the geometry option?
Choose it for a solid round core and an optional concentric solid jacket. For stranded, armored or multicore cable use product-specific linear mass data.
Can I enter the original length on a partly used reel?
Use a current remaining-length reading only. An original shipment tag can conflict with the actual weight after some wire is used.
Why can both tags pass individually but fail together?
Each tag may need a different value inside the catalog range. If no single linear mass fits both, compare the part numbers, tags and scale readings.
Do two partial reels cover one long run?
The pooled estimate adds both reels. For an uncut run, use the single-reel estimate, which takes the longest length on one reel.
Similar Calculators
12V DC Shared Feeder Wire Sizing Calculator
Compare three 12V DC cable options in a shared feeder and two branches. See terminal voltage, current margins and the cheapest qualifying wire combination.
DC Voltage Drop & Cable Loss Calculator
Compare DC cable voltage drop, power losses and load limits with separate conductor lengths, connection resistance, constant-power loads and visual sweeps.
Rebar Weight Calculator & Bundle Scale Audit
Calculate nominal rebar weight by size, count and length. Reconcile each measured bundle with the net scale ticket and chart its signed variance.
Pipe Weight Calculator & Contents Planner
Compare empty, partly filled and full pipe weights from measured outside diameter and wall thickness, listed dry mass and separate fittings.
Fishing Reel Line Capacity & Backing Calculator
Compare fishing reel line and backing from a documented spool rating. Plot modeled fill and find the maximum backing or main-line length.
Electrical Wiring Cost & Cable Reel Cut Planner