Air Conditioner Electricity Cost & Duty Cycle Calculator
Use separate whole-system readings for compressor-on, fan-only and standby. Enter up to six daily time blocks and compare two schedules on the same prices. The charts show where each plan uses electricity and how the price of each time block affects its share of the bill.
Compare two air conditioner schedules
Apply the same entered electricity prices to measured power states and two daily schedules. See how timing changes the energy charge.
Set the billing period and measured power
Use whole-system electrical watts for each state at the same meter. Enter how many days repeat this profile.
Peak
Enter rates and duty by time block
Blocks must total 1,440 minutes. Within each block, standby fills the share left after compressor-on and fan-only time.
Compare electricity and billing cost
Plan B costs $14.27 less. Plan B uses 1.6711 kWh more each day.
Peak compressor duty under the $90.00 cap
Only compressor and standby shares in this block vary. Fan-only time and all other blocks stay fixed.
- Plan A
- 0% to 54.97%
- Plan B
- 0% to 53.39%
Daily cost by time block
Cost bars share a $1.99 daily scale. The energy chart below shares one kWh scale across the two plans.
Off peak
480 min · $0.12/kWh
Shoulder
600 min · $0.2/kWh
Peak
360 min · $0.39/kWh
Daily energy by power state
- Compressor on
- 12.35 kWh
- Fan only
- 0.112 kWh
- Standby
- 0.0774 kWh
- Compressor on
- 14.06 kWh
- Fan only
- 0.112 kWh
- Standby
- 0.0385 kWh
Reconcile the time-block worksheet
The CSV includes electricity and cost by state, plus exact numerators for each daily contribution.
Open usage and cost ledger
| Block and plan | Compressor | Fan only | Standby | Daily energy | Daily cost |
|---|---|---|---|---|---|
| Off peak · Plan A | 20% | 10% | 70% | 2.1696 kWh | $0.26 |
| Off peak · Plan B | 85% | 8% | 7% | 6.8348 kWh | $0.82 |
| Shoulder · Plan A | 40% | 5% | 55% | 5.268 kWh | $1.05 |
| Shoulder · Plan B | 45% | 10% | 45% | 4.5725 kWh | $0.91 |
| Peak · Plan A | 65% | 5% | 30% | 5.1018 kWh | $1.99 |
| Peak · Plan B | 46% | 10% | 44% | 2.8032 kWh | $1.09 |
View selectable electricity CSV
How to use this calculator
- Enter how many billing days repeat the same profile, then enter measured whole-system power for the three operating states of each plan.
- Enter the minutes and per-kWh price for each daily time block. Include unpriced or free periods and make the minutes add to 1,440.
- Enter each plan’s compressor-on and fan-only percentages in each block. Standby accounts for the remaining time.
- Compare daily electricity use, the two billing totals and the visual cost by block. Open the ledger or export the detailed CSV.
- To explore the optional energy charge cap, enter the amount and choose which time block can change. Compare the feasible compressor percentages for both plans.
The Formula
The mathematical logic powering this calculation is:
For each time block, multiply each plan’s compressor, fan-only and standby watts by the corresponding fraction of the block and the block duration in hours. Divide watt-hours by 1,000 to get kilowatt-hours. The standby share is 100% less the two entered shares. Three states cover every minute of a day. Use average measured electrical draw if power varies within a state.
Multiply block kilowatt-hours by that block’s price per kilowatt-hour. Sum across the day and multiply by the number of times the full day repeats. The comparison uses the full input precision. Currency is rounded for display, and the CSV includes exact numerators plus the shared denominators.
For an entered cost cap, vary compressor share in the selected block by steps of 0.01 percentage points. Keep fan time in that block and every other block fixed. The changed fraction comes from standby. Solve the resulting linear cost equation for all inclusive duty values at or under the cap. When the two affected states have the same effective price, all feasible duty values qualify or none qualify. The calculation uses the energy charge for this device and entered schedule, excluding recurring fees, demand charges, all other loads and taxes.Worked Example
If you input:
- Billing days: 30 repeating days
- Plan A measured compressor, fan and standby: 1,300 W / 70 W / 6 W
- Plan B measured compressor, fan and standby: 1,000 W / 50 W / 5 W
- Block minutes and prices: 480 min at $0.12, 600 min at $0.20, 360 min at $0.39 per kWh
- Plan A compressor and fan-only shares: 20% / 10%, 40% / 5%, 65% / 5%
- Plan B compressor and fan-only shares: 85% / 8%, 45% / 10%, 46% / 10%
- Energy-charge cap: $90, varying the 360-minute peak block
Result:
Plan A uses 12.5394 kWh per day and costs $99.11 over 30 days. Plan B uses 14.2105 kWh per day and costs $84.84. The $90 cap allows compressor share through 54.97% for A and through 53.39% for B in the selected block.
Frequently Asked Questions
Why does Plan B cost less in the example despite using more electricity?
Plan B uses more kWh during lower-priced hours while using less during the most expensive period. The flat-price example keeps the same measured loads and shares and reverses the cost ordering.
Does compressor-on power include fans that run at the same time?
Yes. Use the whole unit’s measured wattage while the compressor and its associated fans run. Only the separate fan-only state uses the fan-only wattage.
How can I model a day when the air conditioner draws no power for a block?
Set compressor-on and fan-only shares to zero. The remaining time uses the entered standby draw. Enter measured zero standby watts when the unit draws no power in that state.
How do I model days with different rates or schedules?
Use a separate worksheet for each repeating daily profile, with the matching number of days. Whole-bill rate structures can be explored in the Electricity Tariff Planner.
What does the compressor percentage under the cap mean?
It is the interval of modeled percentages that meets the cap with all other time blocks and fan-only time unchanged. The model does not estimate room temperature or propose a thermostat setting.
Similar Calculators
Electricity Bill & Rate Comparison Calculator
Compare electricity bills with flat, time-of-use or tiered rates. Enter usage and fees, then find how much peak electricity you would need to shift to break even.
Electricity Cost Calculator
Estimate appliance electricity cost from wattage, daily use, electricity rate, and billing fees.
Mini-Split Zone Capacity & Quote Planner
Compare mini-split installation quotes against matched room and outdoor-unit capacities. See individual and shared shortfalls at one common rating point.
HVAC Replacement & Operating Cost Planner
Compare HVAC replacement quotes, annual heating and cooling costs, maintenance and dated repairs. Visualize nominal and discounted costs, savings and payback reversals.
Energy Efficiency Ratio & Cooling Meter Calculator
Calculate measured cooling efficiency in Btu/Wh across matched meter intervals. Compare uncertainty, electricity use and headroom to your own EER target.
Window Air Conditioner Size & Opening Fit Calculator
Compare the measured width and height of a window with two air conditioners’ listed opening limits and your target cooling capacity. See which edge controls the fit.