Air Conditioner Electricity Cost & Duty Cycle Calculator

Use separate whole-system readings for compressor-on, fan-only and standby. Enter up to six daily time blocks and compare two schedules on the same prices. The charts show where each plan uses electricity and how the price of each time block affects its share of the bill.

Energy cost

Compare two air conditioner schedules

Apply the same entered electricity prices to measured power states and two daily schedules. See how timing changes the energy charge.

Set the billing period and measured power

Use whole-system electrical watts for each state at the same meter. Enter how many days repeat this profile.

Peak

Plan A measured draw
Plan B measured draw

Enter rates and duty by time block

Blocks must total 1,440 minutes. Within each block, standby fills the share left after compressor-on and fan-only time.

Block 1
Plan A
Plan B
Block 2
Plan A
Plan B
Block 3
Plan A
Plan B

Compare electricity and billing cost

Plan A · 30 days
$99.11
$3.30 per day · 12.5394 kWh per day
Plan B · 30 days
$84.84
$2.83 per day · 14.2105 kWh per day

Plan B costs $14.27 less. Plan B uses 1.6711 kWh more each day.

Peak compressor duty under the $90.00 cap

Only compressor and standby shares in this block vary. Fan-only time and all other blocks stay fixed.

Plan A
0% to 54.97%
Plan B
0% to 53.39%

Daily cost by time block

Cost bars share a $1.99 daily scale. The energy chart below shares one kWh scale across the two plans.

Off peak

480 min · $0.12/kWh

Plan A$0.26
Plan B$0.82

Shoulder

600 min · $0.2/kWh

Plan A$1.05
Plan B$0.91

Peak

360 min · $0.39/kWh

Plan A$1.99
Plan B$1.09

Daily energy by power state

Plan A12.5394 kWh
Compressor on
12.35 kWh
Fan only
0.112 kWh
Standby
0.0774 kWh
Plan B14.2105 kWh
Compressor on
14.06 kWh
Fan only
0.112 kWh
Standby
0.0385 kWh

Reconcile the time-block worksheet

The CSV includes electricity and cost by state, plus exact numerators for each daily contribution.

Open usage and cost ledger
Block and planCompressorFan onlyStandbyDaily energyDaily cost
Off peak · Plan A20%10%70%2.1696 kWh$0.26
Off peak · Plan B85%8%7%6.8348 kWh$0.82
Shoulder · Plan A40%5%55%5.268 kWh$1.05
Shoulder · Plan B45%10%45%4.5725 kWh$0.91
Peak · Plan A65%5%30%5.1018 kWh$1.99
Peak · Plan B46%10%44%2.8032 kWh$1.09
Download electricity cost CSV
View selectable electricity CSV

How to use this calculator

  1. Enter how many billing days repeat the same profile, then enter measured whole-system power for the three operating states of each plan.
  2. Enter the minutes and per-kWh price for each daily time block. Include unpriced or free periods and make the minutes add to 1,440.
  3. Enter each plan’s compressor-on and fan-only percentages in each block. Standby accounts for the remaining time.
  4. Compare daily electricity use, the two billing totals and the visual cost by block. Open the ledger or export the detailed CSV.
  5. To explore the optional energy charge cap, enter the amount and choose which time block can change. Compare the feasible compressor percentages for both plans.

The Formula

The mathematical logic powering this calculation is:

For each time block, multiply each plan’s compressor, fan-only and standby watts by the corresponding fraction of the block and the block duration in hours. Divide watt-hours by 1,000 to get kilowatt-hours. The standby share is 100% less the two entered shares. Three states cover every minute of a day. Use average measured electrical draw if power varies within a state.

Multiply block kilowatt-hours by that block’s price per kilowatt-hour. Sum across the day and multiply by the number of times the full day repeats. The comparison uses the full input precision. Currency is rounded for display, and the CSV includes exact numerators plus the shared denominators.

For an entered cost cap, vary compressor share in the selected block by steps of 0.01 percentage points. Keep fan time in that block and every other block fixed. The changed fraction comes from standby. Solve the resulting linear cost equation for all inclusive duty values at or under the cap. When the two affected states have the same effective price, all feasible duty values qualify or none qualify. The calculation uses the energy charge for this device and entered schedule, excluding recurring fees, demand charges, all other loads and taxes.

Worked Example

If you input:

  • Billing days: 30 repeating days
  • Plan A measured compressor, fan and standby: 1,300 W / 70 W / 6 W
  • Plan B measured compressor, fan and standby: 1,000 W / 50 W / 5 W
  • Block minutes and prices: 480 min at $0.12, 600 min at $0.20, 360 min at $0.39 per kWh
  • Plan A compressor and fan-only shares: 20% / 10%, 40% / 5%, 65% / 5%
  • Plan B compressor and fan-only shares: 85% / 8%, 45% / 10%, 46% / 10%
  • Energy-charge cap: $90, varying the 360-minute peak block

Result:

Plan A uses 12.5394 kWh per day and costs $99.11 over 30 days. Plan B uses 14.2105 kWh per day and costs $84.84. The $90 cap allows compressor share through 54.97% for A and through 53.39% for B in the selected block.

Frequently Asked Questions

Why does Plan B cost less in the example despite using more electricity?

Plan B uses more kWh during lower-priced hours while using less during the most expensive period. The flat-price example keeps the same measured loads and shares and reverses the cost ordering.

Does compressor-on power include fans that run at the same time?

Yes. Use the whole unit’s measured wattage while the compressor and its associated fans run. Only the separate fan-only state uses the fan-only wattage.

How can I model a day when the air conditioner draws no power for a block?

Set compressor-on and fan-only shares to zero. The remaining time uses the entered standby draw. Enter measured zero standby watts when the unit draws no power in that state.

How do I model days with different rates or schedules?

Use a separate worksheet for each repeating daily profile, with the matching number of days. Whole-bill rate structures can be explored in the Electricity Tariff Planner.

What does the compressor percentage under the cap mean?

It is the interval of modeled percentages that meets the cap with all other time blocks and fan-only time unchanged. The model does not estimate room temperature or propose a thermostat setting.