Window Air Conditioner Size & Opening Fit Calculator

Use the clear opening’s measurements and allowances, the minimum and maximum width from each unit’s installation guide, and its listed minimum height and cooling capacity. Compare the full measured range and see when a closer measurement would change the result.

Measured opening and listed capacity

Compare window air conditioner sizes

Edit the measured opening and listed sizes
Unit A
Unit B

Only Unit A meets the entered opening and capacity limits.

Target cooling capacity 6,000 to 8,000 BTU/h

Unit A

Full opening and capacity match
Opening width
Entirely within
26 to 36 in
Clear height
Entirely within
14 in minimum
Cooling capacity
Entirely within
6,500 BTU/h listed

Unit B

Opening partly inside listed dimensions
Opening width
Partly within
26.125 to 38 in
Clear height
Partly within
14.125 in minimum
Cooling capacity
Entirely within
8,000 BTU/h listed

Use the manufacturer’s instructions to verify the window type, support, clearances and power for the exact model and kit.

Inspect your opening and listed fit range

Opening width close-up

Lower listed boundary

25.9813 in26.1438 in
  • Listed opening
  • Measured range

Unit A · Opening width

Measured range 26 to 26.125 in

Listed opening 26 to 36 in

Entirely within

0 in full-range margin

0.0625 in maximum symmetric allowance at nominal

Review the exact window AC fit ledger
Exact opening intervals and capacity checks
UnitCheckMeasured lowMeasured highRequired lowRequired highFull-range marginCoverage
AOpening width (in)26209/826360Entirely within
AClear height (in)1457/414–0Entirely within
ACooling capacity (BTU/h)6500650060008000500Entirely within
BOpening width (in)26209/8209/838-1/8Partly within
BClear height (in)1457/4113/8–-1/8Partly within
BCooling capacity (BTU/h)80008000600080000Entirely within

How to use this calculator

  1. Record the clear width and height using the references named in the candidate units’ documentation.
  2. Enter any uncertainty or tape rounding allowance in inches, with separate values for width and height.
  3. Enter your room’s selected cooling capacity range. Copy the published opening width band, minimum height and listed capacity of each unit.
  4. Inspect each comparison and its remaining width or height allowance. Download the exact result if needed.

The Formula

The mathematical logic powering this calculation is:

For a measured width or height w and a user-entered symmetric measurement allowance a, the worksheet compares the full interval [w − a, w + a]. The width must stay inside the same model and kit’s documented minimum and maximum. The height must stay at or above its minimum. The two allowances represent uncertainty in the measurements only. A lower clear dimension can control even if the nominal dimension meets the limit.
For a two-sided band, the full-range margin is the smaller of measured low minus listed low and listed high minus measured high. For a minimum-only check it is measured low minus listed minimum. The maximum symmetric allowance at a fixed nominal measurement is its distance to the closest relevant listed bound, if the nominal value is inside. If the two intervals are disjoint, report the shortest separation. Overlap at exactly one point is included in the overlap but does not cover the full range unless the measured interval is itself a point.
The equipment’s listed BTU/h is compared with the user’s entered cooling capacity interval, including both endpoints. A unit meets the entered scope when both measured opening intervals are fully covered and the listed capacity is in range. Enter the capacity band from your room-specific assessment. The ENERGY STAR source explains how room conditions affect sizing. No generic room-load estimate is applied.
Use the actual model and its specified window type, opening reference and kit. The comparison covers listed opening dimensions and capacity. Mounting, structure, obstructions, outdoor clearance, electrical supply and applicable requirements rely on the product documentation. Measurements accept up to four decimal inches, 0–1,000 in. Opening dimensions and listed minimums are positive. Enter allowances smaller than their nominal dimensions and whole positive BTU/h values through 1,000,000. Exact comparisons and CSV use rational arithmetic.

Worked Example

If you input:

  • Opening: 26.0625 in clear width ± 0.0625 in and 14.125 in clear height ± 0.125 in
  • Capacity target: 6,000–8,000 BTU/h
  • Unit A: 26–36 in width, 14 in minimum height, 6,500 BTU/h
  • Unit B: 26.125–38 in width, 14.125 in minimum height, 8,000 BTU/h

Result:

Unit A covers the complete 26–26.125 in width interval and 14–14.25 in height interval. Unit B’s allowable width touches the measured interval only at 26.125 in, and its required height covers only part of the measured range.

Frequently Asked Questions

Why might the listed window width differ from the air conditioner’s outer width?

An opening specification may account for the exact window kit or the side panels and their adjustment range. Copy the opening requirements rather than the bare cabinet size.

What if the window’s measurements vary by position?

Use the measurement locations and clearances specified for that installation. The entered interval can represent the range you are comparing. The arithmetic cannot determine which opening location or obstruction controls in a specific frame.

What does a partial match mean?

Some values in your measured interval meet the listed limit, while others miss it. Review the boundary and narrow the input range only if better measurements support it.

Does an opening and capacity match approve mounting?

It confirms the two dimensions and the one capacity comparison you entered. The manufacturer’s instructions address window type, support, conditions, clearances and power.