Transient Thermal Impedance Calculator

Enter Foster resistance and time-constant pairs for a fixed device case. Compare the first and last pulse of a power train with its long-run cycle, then check each peak against your target.

Transient thermal

Compare first, finite and repeating pulse heating

Pulse and thermal model

The case stays at its entered temperature. The first pulse starts after the off power has reached thermal equilibrium.

Foster branch terms

Use coefficients for the same device and case boundary. Convert a time constant in seconds to milliseconds.

Branch 1
Branch 2

Junction temperature peaks

First pulse
59.70377 °C
3.296231 °C below target
Pulse 5
65.43661 °C
2.436607 °C above target
Repeating limit
66.33162 °C
3.331622 °C above target
First above target at pulse 3
Off equilibrium
44 °C
Further rise at limit
0.8950141 °C
Duty cycle
30%
Average dissipation
8.6 W
Temperature through one cycle

Rise above off-power equilibrium in °C. Vertical scale 0–22.33162.

Pulse heating and cooling comparisonThe first pulse is gray and dashed, the entered-count pulse is green and solid, and the periodic limit is violet and dotted. On and off phases each use half of the horizontal axis.On phaseOff phase
30 ms on70 ms off
First pulseRepeating limitEntered pulse Entered target

Both phases use equal chart width. The durations above are the actual times.

Cycle ledger and CSV
Calculated cycle temperatures in degrees Celsius
CycleStart °CPeak °CEnd °C
First4459.7037747.13058
Pulse 550.7511865.4366151.16033
Repeating51.7910366.3316251.79103
Branch peak rise above off equilibrium (°C)
TermFirstEnteredLimit
111.4135711.4281211.42812
24.29019410.0084910.9035

How to use this calculator

  1. Enter the measured or assumed fixed case temperature and a junction temperature target from your analysis.
  2. Enter on and off dissipated power, both dwell times in milliseconds and the number of on pulses. The first pulse starts at the off-power thermal equilibrium.
  3. Enter one to four Foster terms from a matching junction-to-case model. Convert supplied time constants in seconds to milliseconds.
  4. Compare the first, entered-count and repeating-cycle peaks. Check which pulse first exceeds the target within the run, then inspect the phase plot and branch ledger.

The Formula

The mathematical logic powering this calculation is:

For one Foster term, the unit-step thermal impedance is R(1 − exp(−t/τ)), with resistance R in K/W and time constant τ in the same units as time t. First add the steady off-power rise Poff ∑R to the fixed case temperature. The formulas below describe the extra rise above that baseline.

Let T = ton + toff and ΔP = Pon − Poff. For a branch, the first peak is F = ΔP R(1 − exp(−ton/τ)). Its peak after N pulses is F(1 − exp(−NT/τ))/(1 − exp(−T/τ)). The repeating-cycle peak uses the same denominator with numerator multiplier 1. At low power, each branch decays from its peak by exp(−toff/τ). Each cycle starts from the previous cycle's end. Because on power is at least off power and the first cycle starts from off equilibrium, the warm-up peaks are monotone.

The sum of branch rises gives junction temperature relative to the off equilibrium. The target check uses monotone search through the entered pulse count and treats values within floating-point tolerance as at the target. The model keeps the remaining rise to the repeating peak using the exponential tail, even when rounded temperatures match. Duty is ton/T. The cycle average power alone does not determine the peak.

Enter one to four terms with R from 0.000001 to 1,000 K/W, τ and both durations from 0.001 to 100,000,000 ms, nonnegative powers up to 10,000 W, and temperatures from −150 to 1,000 °C. These values accept up to six decimals. Enter one to one billion pulses. The plot divides the on and off phases into equal visual widths and samples each phase at 48 steps.

Use a junction-to-case Foster fit for the device and reference surface. The model keeps that surface at the entered fixed temperature and assumes the thermal coefficients remain constant. It does not model case-to-ambient heating, local hot spots or device operating limits.

Worked Example

If you input:

  • Case temperature (°C): 40
  • Target junction (°C): 63
  • On power (W): 24
  • Off power (W): 2
  • On duration (ms): 30
  • Off duration (ms): 70
  • Pulse count: 5
  • Resistance (K/W): 0.6 and 1.4
  • Time constant (ms): 15 and 200

Result:

The 2 W off-power equilibrium is 44 °C. The first pulse reaches about 59.70377 °C, pulse 5 reaches 65.43661 °C and the repeating-cycle limit peaks at 66.33162 °C. The first peak above the 63 °C target is pulse 3.

Frequently Asked Questions

Why does the first pulse run cooler than a later pulse?

During the off phase the excess rise decays gradually. The next pulse can start from residual heat left by earlier pulses, especially for large time constants.

What does the repeating-cycle limit represent?

It is the periodic temperature waveform approached as the same pulse train continues. A finite run can stay below the target even when the repeating-cycle peak is above it.

What temperature should I enter for the case?

Use the fixed surface temperature at the boundary of the entered thermal model. A junction-to-case coefficient pair is referenced to that surface, which can differ from the air temperature.

What if the off power is greater than zero?

The first pulse begins after that power has established equilibrium. Enter a zero off power to start at the case temperature.

Can I combine the branch terms with my heat sink resistance?

This worksheet uses Foster terms with a fixed thermal boundary. A changing case or heat sink temperature requires a compatible network or separate transient analysis.

Does reaching the target confirm device operating limits?

The target check compares the modeled junction temperature to your chosen condition. Device electrical limits, rated operating regions and package-specific rules require the manufacturer's data.