Passive Filter Bode Plot & Load Planner
Compare two physical resistor-capacitor or series RLC circuits on the same Bode plots. See how source and load resistance move the half-power points and change gain and phase at a selected frequency. Use a shared minimum gain to decide whether either circuit passes with the entered components.
Compare loaded passive filters
See what the source and receiving load do to a circuit’s cutoff, gain and phase before choosing components.
Circuit B meets the minimum gain.
At 200 Hz with a -6 dB minimum.
Half-power corner 318.3099 Hz
Passband reference -6.0206 dB
Half-power corner 160.7465 Hz
Passband reference -0.0864 dB
- Circuit A
- Circuit B
- Test at 200 Hz
- Minimum gain
Logarithmic frequency in Hz. Vertical values are gain in dB relative to the source. Hollow marks show half-power frequencies. A filled landmark marks resonance.
- Circuit A
- Circuit B
- Test at 200 Hz
Logarithmic frequency in Hz. Vertical values are output phase in degrees relative to the source. Hollow marks show half-power frequencies. A filled landmark marks resonance.
Open frequency and landmark ledger
Half-power gain is about 3.0103 dB below the circuit’s own passband reference. Frequencies outside the sweep remain in this list.
| Circuit | Landmark | Frequency | Gain | Phase | Sweep |
|---|---|---|---|---|---|
| Circuit A | Half-power corner | 318.3099 Hz | -9.0309 dB | -45° | In sweep |
| Circuit B | Half-power corner | 160.7465 Hz | -3.0967 dB | -45° | In sweep |
Sweep samples
| Frequency | A gain | A phase | B gain | B phase |
|---|---|---|---|---|
| 10 Hz | -6.0249 dB | -1.7994° | -0.1032 dB | -3.5598° |
| 11.5478 Hz | -6.0263 dB | -2.0777° | -0.1088 dB | -4.109° |
| 13.3352 Hz | -6.0282 dB | -2.3989° | -0.1162 dB | -4.7423° |
| 15.3993 Hz | -6.0308 dB | -2.7697° | -0.1261 dB | -5.4721° |
| 17.7828 Hz | -6.0341 dB | -3.1976° | -0.1393 dB | -6.3128° |
| 20.5353 Hz | -6.0386 dB | -3.6912° | -0.1567 dB | -7.2801° |
| 23.7137 Hz | -6.0446 dB | -4.2606° | -0.1799 dB | -8.3919° |
| 27.3842 Hz | -6.0526 dB | -4.917° | -0.2107 dB | -9.6679° |
| 31.6228 Hz | -6.0633 dB | -5.6735° | -0.2513 dB | -11.1294° |
| 36.5174 Hz | -6.0774 dB | -6.5445° | -0.305 dB | -12.7989° |
| 42.1697 Hz | -6.0962 dB | -7.5466° | -0.3755 dB | -14.6995° |
| 48.6968 Hz | -6.1211 dB | -8.698° | -0.4678 dB | -16.8537° |
| 56.2341 Hz | -6.1541 dB | -10.0188° | -0.5878 dB | -19.2814° |
| 64.9382 Hz | -6.1977 dB | -11.5306° | -0.743 dB | -21.9977° |
| 74.9894 Hz | -6.2552 dB | -13.2564° | -0.9416 dB | -25.0094° |
| 86.5964 Hz | -6.3307 dB | -15.219° | -1.193 dB | -28.312° |
| 100 Hz | -6.4294 dB | -17.4406° | -1.5072 dB | -31.8856° |
| 115.4782 Hz | -6.5576 dB | -19.94° | -1.8936 dB | -35.693° |
| 133.3521 Hz | -6.7229 dB | -22.7307° | -2.3607 dB | -39.6784° |
| 153.9927 Hz | -6.9339 dB | -25.8169° | -2.9143 dB | -43.7707° |
| 160.7465 Hz | -7.0071 dB | -26.7938° | -3.0967 dB | -45° |
| 177.8279 Hz | -7.2003 dB | -29.1905° | -3.5574 dB | -47.8882° |
| Test · 200 Hz | -7.4657 dB | -32.1419° | -4.1485 dB | -51.21° |
| 205.3525 Hz | -7.5318 dB | -32.8274° | -4.2893 dB | -51.9468° |
| 237.1374 Hz | -7.9379 dB | -36.6857° | -5.1056 dB | -55.8681° |
| 273.842 Hz | -8.4264 dB | -40.7054° | -5.9994 dB | -59.5869° |
| 316.2278 Hz | -9.0025 dB | -44.812° | -6.9618 dB | -63.0546° |
| 318.3099 Hz | -9.0309 dB | -45° | -7.0071 dB | -63.2062° |
| 365.1741 Hz | -9.6682 dB | -48.9224° | -7.9828 dB | -66.2413° |
| 421.6965 Hz | -10.422 dB | -52.9533° | -9.0528 dB | -69.1337° |
| 486.9675 Hz | -11.2587 dB | -56.8291° | -10.1628 dB | -71.7321° |
| 562.3413 Hz | -12.1707 dB | -60.4882° | -11.3047 dB | -74.0473° |
| 649.3816 Hz | -13.1488 dB | -63.8871° | -12.4719 dB | -76.0966° |
| 749.8942 Hz | -14.1831 dB | -67.0001° | -13.6587 dB | -77.9012° |
| 865.9643 Hz | -15.264 dB | -69.8177° | -14.8607 dB | -79.484° |
| 1,000 Hz | -16.3827 dB | -72.3432° | -16.0744 dB | -80.868° |
| 1,154.782 Hz | -17.5316 dB | -74.5894° | -17.2969 dB | -82.0753° |
| 1,333.5214 Hz | -18.7043 dB | -76.5748° | -18.5262 dB | -83.1266° |
| 1,539.9265 Hz | -19.8953 dB | -78.3212° | -19.7607 dB | -84.0407° |
| 1,778.2794 Hz | -21.1006 dB | -79.8516° | -20.9989 dB | -84.8348° |
| 2,053.525 Hz | -22.3167 dB | -81.1889° | -22.2401 dB | -85.5241° |
| 2,371.3737 Hz | -23.5412 dB | -82.3549° | -23.4835 dB | -86.1221° |
| 2,738.4196 Hz | -24.7719 dB | -83.3698° | -24.7285 dB | -86.6406° |
| 3,162.2777 Hz | -26.0074 dB | -84.2521° | -25.9748 dB | -87.09° |
| 3,651.7413 Hz | -27.2465 dB | -85.0183° | -27.222 dB | -87.4795° |
| 4,216.965 Hz | -28.4883 dB | -85.6833° | -28.4699 dB | -87.817° |
| 4,869.6753 Hz | -29.7321 dB | -86.2601° | -29.7183 dB | -88.1094° |
| 5,623.4133 Hz | -30.9775 dB | -86.7603° | -30.9671 dB | -88.3626° |
| 6,493.8163 Hz | -32.224 dB | -87.1938° | -32.2163 dB | -88.582° |
| 7,498.9421 Hz | -33.4714 dB | -87.5694° | -33.4656 dB | -88.772° |
| 8,659.6432 Hz | -34.7195 dB | -87.8949° | -34.7151 dB | -88.9366° |
| 10,000 Hz | -35.968 dB | -88.1768° | -35.9647 dB | -89.0791° |
Show selectable CSV
How to use this calculator
- Choose a shared frequency sweep, a test frequency inside it and the minimum acceptable gain relative to the ideal source.
- Choose the topology for each circuit. Enter the source, physical load and component values using the displayed units.
- Read the test gain and phase. Compare passband references and the half-power positions to separate loading loss from frequency rolloff.
- Open the frequency and landmark ledger or export the CSV to compare exact probe and landmark data with your measurements.
The Formula
The mathematical logic powering this calculation is:
Use angular frequency ω = 2πf with f in Hz, capacitance C in farads and inductance L in henries. Let Rₛ be source resistance, R be the filter resistor and Rₗ be the next-stage load. For RC low pass, let Rₜ = Rₛ + R and τ = C × (Rₜ ‖ Rₗ). The transfer ratio is H = [Rₗ/(Rₜ + Rₗ)] / (1 + jωτ). For RC high pass, let Rₚ = R ‖ Rₗ and τ = C × (Rₛ + Rₚ). The transfer ratio is H = jωCRₚ / (1 + jωτ). Parallel notation U ‖ V means UV/(U + V). Both RC half-power frequencies are 1/(2πτ).
For series RLC band pass, the output is across Rₗ. Let RΣ = Rₛ + Rₗ + coil series loss. Then H = Rₗ/[RΣ + j(ωL − 1/(ωC))]. The resonant frequency is 1/(2π√LC). Half-power points satisfy |ωL − 1/(ωC)| = RΣ. In Hz the bandwidth is RΣ/(2πL) and Q = resonant frequency / bandwidth. The half-power reference is each circuit’s passband limit or resonant peak, so its gain there is lower than that reference by 10 log₁₀(2), about 3.0103 dB.
The magnitude plot uses 20 log₁₀|H| in dB relative to the ideal voltage source. The phase plot uses arg(H) in degrees. The entered minimum is compared to the source-referenced test gain before rounding. The logarithmic sweep includes the exact probe and any in-range computed landmarks. The table also lists landmarks outside the plot.
Enter a finite source resistance or series loss from 0 to 1 billion Ω, filter or load resistance from 0.001 to 1 billion Ω, C or L from 0.000001 to 1 million in the displayed units, and frequencies from 0.000001 to 1 trillion Hz. This is the ideal lumped, linear, steady-state model with finite load. Component tolerances, amplifier limits and unentered parasitic effects are outside the model.Worked Example
If you input:
- Circuit A and B topology: RC low pass
- Source and filter resistance: 50 Ω source and 950 Ω series resistor in both circuits
- Capacitance: 1 µF in both circuits
- A and B load resistance: 1 kΩ and 100 kΩ
- Sweep and target: 10–10,000 Hz, with at least −6 dB at 200 Hz
Result:
Circuit A has a 318.3099 Hz half-power corner and delivers −7.4657 dB at 200 Hz. Circuit B has a 160.7465 Hz corner and delivers −4.1485 dB. Only Circuit B reaches the entered −6 dB minimum at 200 Hz.
Frequently Asked Questions
Why can a heavier load raise the cutoff yet reduce measured gain?
The receiving load forms a divider with the source side of an RC low-pass circuit. Decreasing the load reduces the capacitor’s effective resistance, so the pole moves higher. The same lower load also reduces the available output voltage across the passband.
Is the half-power mark always −3 dB on the magnitude plot?
The mark is about 3.0103 dB below that circuit’s own passband reference. The plot uses the ideal source voltage as zero, so a loaded circuit can have a lower half-power mark on the graph.
Which resistance belongs in the RLC load field?
Use the resistor across which you read output, modeled as part of the series path. Enter generator resistance and the inductor’s known series loss separately. The sum affects bandwidth and the load alone sets the output numerator.
Can I model a high-impedance load?
Enter the finite resistance of the receiving device. If it has significant input capacitance or changes with frequency, this simple fixture may be insufficient. Its stated resistance is an editable circuit assumption.
What happens if a half-power frequency is outside the sweep?
You can still read it in the landmark ledger. The chart marks only frequencies inside the entered sweep. Narrow the range around a sharp resonance to inspect both skirts.
Can this check filter response for feedback stability?
The plotted transfer is the passive input-to-output voltage ratio for the stated topology. A feedback loop calls for its own loop transfer model and stability criteria.
Similar Calculators
AC Power & Power Factor Calculator
Calculate AC watts, vars, volt-amps and power factor for single-phase or balanced three-phase loads. Combine leading and lagging loads, compare an ideal target PF and export the ledger.
Equivalent Resistance Calculator
Solve a DC resistor network, including series, parallel and bridge connections. Inspect node voltages, branch currents, power and terminal tolerance bounds.
Ohm's Law Calculator
Calculate voltage, current, or resistance using Ohm's Law — enter any two values to find the third.
DC Voltage Drop & Cable Loss Calculator
Compare DC cable voltage drop, power losses and load limits with separate conductor lengths, connection resistance, constant-power loads and visual sweeps.