Cone & Frustum Capacity Calculator

Explore an upright cone or circular frustum from its measured bottom radius, top radius and perpendicular height. Compare up to three alternatives, including the cylinder limit, and see how liquid volume changes with fill depth. This cone volume calculator combines full capacity, a target-volume depth inverse, section diagrams, shared depth-versus-volume curves, a precise inspector and complete tables. Separate lateral and end-face areas explain the surface geometry, while an ideal zero-thickness sector or rectangle shows how the lateral surface develops. Exact quantity-preserving unit changes keep metric and inch inputs on one page. CSV retains all alternatives and curve checkpoints. The geometry uses the entered inside surface; material thickness, construction allowances and field calibration are separate tasks.

Tapered capacity & surface geometry

See how the taper changes every fill.

Compare cones, frusta and cylinders with linked capacity curves, fill-depth targets and ideal surface developments.

Compare your upright shapes

Enter inside radii and upright height. A zero end radius creates a cone; equal radii create a cylinder. Each alternative is a separate ideal geometry.

Alternative 1

Unique printable name, up to 60 characters.

0 or 0.001–100000 mm in equivalent units; a radius is half the inside diameter.

At least one end radius must be positive. The larger end may be at the top or bottom.

0.001–100000 mm in equivalent units. Height is perpendicular to the circular end faces, rather than slant length.

Inspect a fill and set a target

0–100%, up to six decimal places. This is a height percentage; liquid volume generally changes nonlinearly.

Applies to each alternative separately. A target exceeding capacity is reported explicitly.

Input unit changes preserve valid quantities exactly; repeating conversions may appear as fractions. Correct blank or malformed drafts before changing their unit.

3 alternatives updated. Selected capacity 175.92919 L.

Widening frustum · full capacity

175.92919 L

frustum · upright height 60 cm · bottom radius 20 cm · top radius 40 cm

Computed from the entered inside geometry. Measured dimensions and real vessels can differ from this ideal shape.

Compare the alternatives

Each alternative receives the same target liquid volume independently. Capacities are not added together.

1. Widening frustum

175.92919 L

At 50% height: 59.69026 L (33.928571% full)

Target depth: 42.45385 cm

2. Apex-bottom cone

100.53096 L

At 50% height: 12.566371 L (12.5% full)

Target depth: 59.894181 cm

3. Cylinder reference

301.59289 L

At 50% height: 150.79645 L (50% full)

Target depth: 19.894368 cm

Height and liquid volume tell different stories

Widening frustum · upright section at 50% height
Proportional upright cross-section; blue fill marks the inspected liquid depth.
Inspected depth
30 cm
Radius at the liquid surface
30 cm
Liquid volume
59.69026 L
Remaining space
116.23893 L

Fill to 100 L

Target depth: 42.45385 cm

Radius at target depth
34.151283 cm
Recomputed liquid volume
100 L

The target depth is solved independently of the plotted sample points. Boundary, overcapacity and unresolved states retain the geometry without presenting a guessed depth.

Liquid volume versus height · all alternatives
Top: 301.59289 LBottom: 0 · horizontal axis: height (%)
Shared-scale fill curves; the inspector and complete table provide exact checkpoint values.
0% height100% height
  • 1. Widening frustum · solid blue
  • 2. Apex-bottom cone · dashed purple
  • 3. Cylinder reference · dotted teal

Circles mark resolved target depths. The shared scale lets you compare absolute volumes; a cone reaches only 12.5% of capacity at half height when its apex is at the bottom.

Full fill table · Widening frustum (102 checkpoints)
Selected alternative. Lengths in cm, volumes in L. Authored inspector points retain their values if a target rounds to the same depth.
Height %DepthLocal radiusLiquid volumeVolume %Remaining space
00 cm20 cm0 L0175.92919 L
10.6 cm20.2 cm0.76154719 L0.43287143175.16764 L
21.2 cm20.4 cm1.5383248 L0.8744174.39086 L
31.8 cm20.6 cm2.3304837 L1.3246714173.5987 L
42.4 cm20.8 cm3.1381746 L1.7837714172.79101 L
53 cm21 cm3.9615483 L2.2517857171.96764 L
63.6 cm21.2 cm4.8007557 L2.7288171.12843 L
74.2 cm21.4 cm5.6559475 L3.2149170.27324 L
84.8 cm21.6 cm6.5272745 L3.7101714169.40191 L
95.4 cm21.8 cm7.4148875 L4.2147168.5143 L
106 cm22 cm8.3189373 L4.7285714167.61025 L
116.6 cm22.2 cm9.2395748 L5.2518714166.68961 L
127.2 cm22.4 cm10.176951 L5.7846857165.75224 L
137.8 cm22.6 cm11.131216 L6.3271164.79797 L
148.4 cm22.8 cm12.102521 L6.8792163.82667 L
159 cm23 cm13.091017 L7.4410714162.83817 L
169.6 cm23.2 cm14.096854 L8.0128161.83233 L
1710.2 cm23.4 cm15.120184 L8.5944714160.809 L
1810.8 cm23.6 cm16.161157 L9.1861714159.76803 L
1911.4 cm23.8 cm17.219924 L9.7879857158.70926 L
2012 cm24 cm18.296636 L10.4157.63255 L
2112.6 cm24.2 cm19.391443 L11.0223156.53775 L
2213.2 cm24.4 cm20.504497 L11.654971155.42469 L
2313.8 cm24.6 cm21.635948 L12.2981154.29324 L
2414.4 cm24.8 cm22.785946 L12.951771153.14324 L
2515 cm25 cm23.954644 L13.616071151.97454 L
2615.6 cm25.2 cm25.142191 L14.291086150.787 L
2716.2 cm25.4 cm26.348739 L14.9769149.58045 L
2816.8 cm25.6 cm27.574437 L15.6736148.35475 L
2917.4 cm25.8 cm28.819438 L16.381271147.10975 L
3018 cm26 cm30.083891 L17.1145.8453 L
3118.6 cm26.2 cm31.367948 L17.829871144.56124 L
3219.2 cm26.4 cm32.671759 L18.570971143.25743 L
3319.8 cm26.6 cm33.995476 L19.323386141.93371 L
3420.4 cm26.8 cm35.339248 L20.0872140.58994 L
3521 cm27 cm36.703227 L20.8625139.22596 L
3621.6 cm27.2 cm38.087563 L21.649371137.84163 L
3722.2 cm27.4 cm39.492408 L22.4479136.43678 L
3822.8 cm27.6 cm40.917912 L23.258171135.01128 L
3923.4 cm27.8 cm42.364226 L24.080271133.56496 L
4024 cm28 cm43.831501 L24.914286132.09769 L
4124.6 cm28.2 cm45.319887 L25.7603130.6093 L
4225.2 cm28.4 cm46.829535 L26.6184129.09965 L
4325.8 cm28.6 cm48.360597 L27.488671127.56859 L
4426.4 cm28.8 cm49.913222 L28.3712126.01597 L
4527 cm29 cm51.487562 L29.266071124.44163 L
4627.6 cm29.2 cm53.083768 L30.173371122.84542 L
4728.2 cm29.4 cm54.701989 L31.093186121.2272 L
4828.8 cm29.6 cm56.342378 L32.0256119.58681 L
4929.4 cm29.8 cm58.005085 L32.9707117.9241 L
5030 cm30 cm59.69026 L33.928571116.23893 L
5130.6 cm30.2 cm61.398055 L34.8993114.53113 L
5231.2 cm30.4 cm63.12862 L35.882971112.80057 L
5331.8 cm30.6 cm64.882107 L36.879671111.04708 L
5432.4 cm30.8 cm66.658665 L37.889486109.27052 L
5533 cm31 cm68.458446 L38.9125107.47074 L
5633.6 cm31.2 cm70.2816 L39.9488105.64759 L
5734.2 cm31.4 cm72.128278 L40.998471103.80091 L
5834.8 cm31.6 cm73.998632 L42.0616101.93056 L
5935.4 cm31.8 cm75.892811 L43.138271100.03638 L
6036 cm32 cm77.810967 L44.22857198.118222 L
6136.6 cm32.2 cm79.75325 L45.33258696.175938 L
6237.2 cm32.4 cm81.719812 L46.450494.209377 L
6337.8 cm32.6 cm83.710802 L47.582192.218386 L
6438.4 cm32.8 cm85.726373 L48.72777190.202816 L
6539 cm33 cm87.766674 L49.887588.162515 L
6639.6 cm33.2 cm89.831856 L51.06137186.097332 L
6740.2 cm33.4 cm91.922071 L52.24947184.007117 L
6840.8 cm33.6 cm94.037469 L53.45188681.89172 L
6941.4 cm33.8 cm96.1782 L54.668779.750988 L
7042 cm34 cm98.344416 L55.977.584772 L
70.75641742.45385 cm34.151283 cm100 L56.84105175.929189 L
7142.6 cm34.2 cm100.53627 L57.14587175.392921 L
7243.2 cm34.4 cm102.75391 L58.406473.175283 L
7343.8 cm34.6 cm104.99748 L59.68167170.931708 L
7444.4 cm34.8 cm107.26714 L60.97177168.662046 L
7545 cm35 cm109.56304 L62.27678666.366145 L
7645.6 cm35.2 cm111.88533 L63.596864.043854 L
7746.2 cm35.4 cm114.23416 L64.931961.695024 L
7846.8 cm35.6 cm116.60969 L66.28217159.319502 L
7947.4 cm35.8 cm119.01205 L67.647756.917139 L
8048 cm36 cm121.44141 L69.02857154.487783 L
8148.6 cm36.2 cm123.8979 L70.42487152.031284 L
8249.2 cm36.4 cm126.3817 L71.83668649.54749 L
8349.8 cm36.6 cm128.89294 L73.264147.036252 L
8450.4 cm36.8 cm131.43177 L74.707244.497418 L
8551 cm37 cm133.99835 L76.16607141.930837 L
8651.6 cm37.2 cm136.59283 L77.640839.336359 L
8752.2 cm37.4 cm139.21536 L79.13147136.713833 L
8852.8 cm37.6 cm141.86608 L80.63817134.063108 L
8953.4 cm37.8 cm144.54516 L82.16098631.384033 L
9054 cm38 cm147.25273 L83.728.676458 L
9154.6 cm38.2 cm149.98896 L85.255325.940231 L
9255.2 cm38.4 cm152.75399 L86.82697123.175202 L
9355.8 cm38.6 cm155.54797 L88.415120.381221 L
9456.4 cm38.8 cm158.37105 L90.01977117.558135 L
9557 cm39 cm161.22339 L91.64107114.705795 L
9657.6 cm39.2 cm164.10514 L93.27908611.82405 L
9758.2 cm39.4 cm167.01644 L94.93398.9127486 L
9858.8 cm39.6 cm169.95745 L96.60565.9717404 L
9959.4 cm39.8 cm172.92831 L98.2942713.0008744 L
10060 cm40 cm175.92919 L1000 L

Surface areas and end faces

These describe the entered surface. The two end faces are separate from the lateral development and do not establish material requirements.

Lateral surface
11,921.506 cm²
Bottom end face
1,256.6371 cm²
Top end face
5,026.5482 cm²
Lateral + both end faces
18,204.691 cm²

Slant length: 63.245553 cm

Ideal lateral-surface development

The entered zero-thickness surface unfolds into a circular sector or annular sector. The schematic is sampled and proportional. Thickness, seam, bend, hem, kerf and other fabrication allowances are excluded.

Widening frustum · sector development
Ideal surface schematic; dimensions are listed below. This diagram is not a calibrated cutting template.
Outer sector radius
126.49111 cm
Inner sector radius
63.245553 cm
Sector angle
113.842°
Band width / slant
63.245553 cm
Outer arc / circumference
251.32741 cm
Inner arc / circumference
125.66371 cm

A small nonzero taper remains a frustum. Its sector radii may be very large and its angle very small, while the developed band stays finite. A true cylinder uses the rectangle limit.

Keep the full comparison

CSV includes every alternative, input, geometry, target state, development dimension and fill checkpoint. The selected alternative does not limit export.

Geometry and model limits

  • Each alternative is one upright right circular cone, frustum or cylinder, using inside radii and perpendicular height in a consistent length system. Alternatives are compared independently, not joined or summed.
  • The radius changes linearly between bottom and top. Liquid is level and the shape is upright; tilt, deformation, internal fittings, dished ends and displaced volume are excluded.
  • A shared target volume applies to every alternative independently. Fill percentage is volume percentage and generally differs from height percentage for tapered shapes.
  • Geometry uses floating-point pi and arithmetic. The capacity numerical band is 64 times machine epsilon times capacity; it describes arithmetic classification uncertainty, not measurement uncertainty.
  • A positive target within the capacity numerical band is marked boundary without a solved depth. Larger targets are marked exceeds; an inverse that fails its residual and bracket criteria is unresolved.
  • The inverse solves the smaller filled or free side and retains its complementary coordinate. Authored inspection complements remain authoritative when a target shares the same rounded sample key.
  • The developed lateral surface is an ideal zero-thickness sector or cylinder rectangle. End faces are listed separately; material thickness, stretch, joining allowances, seam overlap and fabrication approval are excluded.
  • The section and sampled development outlines are proportional screen diagrams, not calibrated print patterns or cutting files. Extremely thin features retain their proportions and may be difficult to see; numeric dimensions remain available.
  • US gallons are US liquid gallons, 3.785411784 L each. Display values use eight significant digits with scientific notation for tiny nonzero quantities; CSV preserves unrounded model values.

How to use this calculator

  1. Choose a geometry example, then select an alternative to edit. Enter Alternative name, Bottom inside radius, Top inside radius and Upright height. Use actual radii of one consistent inside surface; a zero end radius represents an apex.
  2. Add or remove alternatives to compare up to three shapes. The named alternatives are independent designs, so their capacities are compared rather than added together. Equal top and bottom radii produce a cylinder reference.
  3. Choose each measurement’s input unit and set Display length unit and Display volume unit. A valid unit change preserves the physical quantity exactly and may show a fraction; correct an invalid draft before switching its unit.
  4. Set Inspect height (%) and Target liquid volume. The first inspects a relative depth in every alternative; the second solves the depth needed for the same volume in each. Read the explicit Empty, Solved, Exceeds capacity, Boundary or Unresolved target state.
  5. Inspect the upright section and depth-versus-volume curves, then open the complete data table. Compare filled volume with remaining capacity, and distinguish lateral wall area from bottom and top end areas. Review the ideal sector or rectangle development dimensions as surface geometry.
  6. Download the complete CSV or open its selectable copy to retain every alternative, target, inspection, development dimension and curve checkpoint. Check measured dimensions and actual container behavior separately when using the result for a real vessel or material plan.

The Formula

The mathematical logic powering this calculation is:

Use bottom inside radius a, top inside radius b and upright perpendicular height H for one right circular shape with parallel horizontal end planes. At least one radius must be positive and H must be positive. Equal radii give a cylinder; exactly one zero radius gives a cone; other unequal positive radii give a frustum. Exact input quantities determine that classification, so a small nonzero taper remains a frustum. These are radii, not diameters.
Full volume V = πH(a² + ab + b²)/3. For a cone this becomes πR²H/3; for a cylinder it becomes πR²H. At depth z, let t = z/H and r(z) = (1 − t)a + tb. The lower-segment volume is V(z) = πz[a² + ar(z) + r(z)²]/3. This follows by integrating the circular area πr(z)² along height. The positive-term frustum form works for both widening and narrowing shapes. With all lengths in millimetres, divide cubic millimetres by 1000000 for litres.
Filled-volume fraction is t[A² + AR + R²]/[A² + AB + B²], where A, B and R are the bottom, top and local radii divided by max(a,b). Remaining capacity is evaluated as the upper segment: (1 − t)[B² + BR + R²]/[A² + AB + B²] times full capacity. This avoids subtracting nearly equal volumes near full height. At zero and full height, endpoint volumes and remaining capacity are explicit. The entered Inspect height (%) uses its exact decimal complement before floating calculation.
For Target liquid volume, zero is an empty state. A target clearly above computed capacity returns Exceeds capacity with the deficit and no invented depth. A positive target within 64 × Number.EPSILON × capacity of the computed capacity is a Boundary state: the calculation cannot reliably distinguish that value from full capacity, so target depth, radius, achieved volume and deficit remain unavailable. This narrow arithmetic band is not an estimate of measurement error or usable headroom.
Interior target depth is solved by bounded bisection of the smaller filled or empty segment, retaining both depth coordinates near full height. At most 240 iterations are allowed. Success requires relative volume residual at most 2 × 10⁻¹² of the positive smaller target fraction and bracket width at most 2 × 10⁻¹² of the smaller depth coordinate. An unresolved inverse returns an explicit state with no numerical depth; geometry and inspection results remain available. A tiny positive target is never replaced with zero through an absolute-volume stopping floor.
Slant length l = sqrt[H² + (a − b)²]. Lateral area = π(a + b)l; bottom end area = πa²; top end area = πb². The sum of all three is the area with both end faces included. Display them separately because an open container or developed wall does not automatically include both ends. End areas describe the entered inside surface geometry, not external blank dimensions.
For unequal radii, set R = max(a,b), r = min(a,b) and Δ = R − r from exact converted quantities. The ideal developed lateral surface is an annular sector with outer radius Rl/Δ, inner radius rl/Δ and angle θ = 2πΔ/l radians. Outer and inner arc lengths are 2πR and 2πr. Radial band width is l, and area equals the lateral area. With equal radii, the cylinder develops to a rectangle of width 2πa and height H. Near the cylinder limit, sector radii may be very large and angle very small; the model retains that taper, uses l directly for band width and never subtracts huge radii or squared radii to recover width or area. The schematic is an ideal surface diagram, without calibrated cut-pattern scale, seams, hems, kerf or thickness corrections.
Each curve includes 101 authored depth percentages from 0 to 100 in steps of one percentage point, plus the exact inspector and a solved target checkpoint, sorted and deduplicated. The target is solved independently of the plotted samples. If its depth rounds to an authored inspector or grid checkpoint, that authored point retains its value; the separate target result remains available. All lengths are calculated canonically in mm, areas in mm² and volumes in litres. Exact unit definitions include 1 cm = 10 mm, 1 in = 25.4 mm, 1 US liquid gallon = 3.785411784 L and 1 m³ = 1000 L. Input unit changes preserve rational quantities and may display a fraction when an exact short decimal is unavailable. Geometric results remain floating-point approximations. Display values use eight significant digits; small nonzero values use scientific notation and CSV retains model precision.
Supports one to three named alternatives. Each radius is zero or 0.001–100000 mm equivalent; height is 0.001–100000 mm equivalent. Target liquid volume is zero or 10⁻¹⁸–10¹² L equivalent. Quantities accept unsigned decimals with up to 12 decimal places or numerator/positive-denominator fractions within the supported text length; signs, exponents, commas and blank required drafts are invalid. Inspect height is 0–100%, with at most six decimal places. The model assumes an upright axis, circular horizontal sections and a linear radius profile. It excludes tilted or oblique cones, nonparallel ends, compound bottoms, thickness, displaced internal hardware, material loading and fabrication approval.

Worked Example

If you input:

  • Widening frustum: Bottom inside radius 20 cm; top inside radius 40 cm; upright height 60 cm
  • Apex-bottom cone: Bottom inside radius 0 cm; top inside radius 40 cm; upright height 60 cm
  • Cylinder reference: Bottom and top inside radius 40 cm; upright height 60 cm
  • Inspect height (%) / Target liquid volume: 50% / 100 L for each alternative independently
  • Display length unit / Display volume unit: cm / L

Result:

The widening frustum has capacity 56π = 175.92919 L. At 30 cm depth, its radius is 30 cm and liquid volume is 19π = 59.69026 L: 33.928571% of capacity, leaving 116.23893 L. The 100 L target needs about 42.45385 cm depth. The apex-bottom cone has capacity 32π = 100.53096 L; at half-height it holds 4π = 12.566371 L, or 12.5%, and its 100 L target needs about 59.894181 cm. The cylinder holds 96π = 301.59289 L, with half-capacity 150.79645 L at 30 cm; its 100 L target is about 19.894368 cm deep. For the widening frustum, slant length is 20√10 = 63.245553 cm and lateral area is 1.1921506 m². Its ideal developed sector has inner radius 63.245553 cm, outer radius 126.49111 cm and angle 1.9869177 radians. These are ideal surface dimensions, with end disks and construction allowances separate.

Frequently Asked Questions

Do I enter radius or diameter, and is height the sloping side?

Enter the inside radius at each horizontal end and the perpendicular upright height between those planes. Radius is half of diameter. The sloping side is a separate result calculated from height and the radius difference. Using an outside diameter, nominal pipe size or slant length in the radius/height fields changes the geometry.

Why is half the height not necessarily half the capacity?

A taper changes cross-sectional area along height. In an apex-bottom cone, volume fraction is the cube of height fraction, so half-height contains 12.5% of full capacity. In an apex-top cone, half-height contains 87.5%. A cylinder has constant cross-section, so half-height is half-capacity. A frustum falls according to its actual end radii.

What does a target near full capacity mean?

Full capacity is a floating-point geometric approximation. A positive target inside the described arithmetic boundary band is deliberately classified as Boundary, with target depth and achieved volume unavailable. This avoids pretending that tiny differences reliably mean full, slightly below full or above full. The band does not include measurement uncertainty, material variation or operational reserve.

What happens if the target exceeds capacity or the inverse cannot resolve it?

A target clearly above capacity shows the excess volume and no target depth. An Unresolved state means the bounded numerical inverse did not meet its stated residual and bracket-width criteria; the final iteration is not presented as a solved answer. Capacity, surface geometry, authored inspection and curve values remain available for a valid geometry.

Why does a nearly cylindrical shape show huge development radii?

A very small but nonzero taper has an annular-sector development whose arc radii grow while its angle shrinks. That is the geometric approach to the cylinder’s rectangular development. The band width remains the finite slant length. Only exactly equal radii are classified as a cylinder; a small taper is not silently removed.

Can I use the development schematic as a fabrication-ready cut pattern?

The diagram and dimensions describe the ideal zero-thickness lateral surface supplied by the entered radii. They do not include material thickness, neutral-axis placement, seam/hem allowances, kerf, forming changes or calibrated printing scale. The top and bottom disks are separate surfaces. A real blank or assembly requires the relevant construction dimensions and process allowances.

Can I mix centimetres, inches, litres and gallons?

Each input quantity has its own supported unit selector, and the report has independent length and volume display units. Valid unit changes preserve the quantity, including exact fractional text when needed. Gallons here are US liquid gallons, not Imperial gallons. Changing a display unit affects presentation rather than the underlying geometry or target.

Does this work for tilted tanks, compound vessels or external material quantities?

The capacity model is for an upright right circular cone, frustum or cylinder with parallel horizontal ends and a linear radius profile. It does not include tilted liquid surfaces, curved or compound bottoms, wall thickness, displaced internal components or deformation. End areas and ideal wall development describe the entered inside surface, so they do not automatically determine external paint area or purchased material.

Similar Calculators