Rafter Span Bending & Deflection Planner
Enter the measured distance between support faces and compare two rectangular members under a common uniform gravity-load case. Find the separate bending and immediate transient deflection limits, the lower of those two modeled spans, and the measured response of each candidate.
Compare two rafter span limits
See how two sections compare at the same measured support span and documented roof pressures.
Support span measurement
Measure between the same two support faces. Enter the pitch and one of the two lengths.
Candidate A
Within both modeled checks
Lower modeled span limit
159.30575 in
- Governing modeled check
- Transient deflection
- Immediate transient deflection
- 0.61037 in
Candidate B
Exceeds bending limit
Lower modeled span limit
134.72194 in
- Governing modeled check
- Bending
- Immediate transient deflection
- 0.61037 in
10 psf dead · 20 psf transient · L/240 transient limit
This comparison covers uniform-load bending and immediate transient deflection.
Candidate A · Within both modeled checks. Candidate B · Exceeds bending limit.
Projected span and slope
- Horizontal projection
- 156 in
- Along the slope
- 195 in
- Rise between supports
- 117 in
- Roof pitch
- 9:12
Modeled span limits
The dark marker shows the measured horizontal span. Each bar ends where its own check reaches the entered limit.
Candidate A
Within limit
Within limit
Candidate B
Exceeds limit
Within limit
Edit uniform roof loads
Use pressures on the horizontal roof projection from one documented load case. Use the transient pressure for the immediate deflection check.
Edit Candidate A
Use actual section dimensions and values documented for this candidate.
Edit Candidate B
Use actual section dimensions and values documented for this candidate.
Check ledger and export
Span margins are the individual modeled limits minus the projected span. Exact checks still apply when displayed numbers round to the same value.
Show stresses and span margins
| Measure | Candidate A | Candidate B |
|---|---|---|
| Bending stress | 1,340.82645 psi | 1,340.82645 psi |
| Adjusted bending value | 1,400 psi | 1,000 psi |
| Bending utilization | 95.77332% | 134.08264% |
| Span margin to bending limit | 3.40514 in | -21.27806 in |
| Immediate transient deflection | 0.61037 in | 0.61037 in |
| Allowed transient deflection | 0.65 in | 0.65 in |
| Transient deflection utilization | 93.903% | 93.903% |
| Span margin to deflection limit | 3.30575 in | 3.30575 in |
| Total line load | 3.33333 lb/in | 3.33333 lb/in |
| Transient line load | 2.22222 lb/in | 2.22222 lb/in |
| Section modulus | 7.5625 in³ | 7.5625 in³ |
| Second moment | 20.79688 in⁴ | 20.79688 in⁴ |
Show selectable CSV text
How to use this calculator
- Choose horizontal or along-slope measurement. Enter the actual face-to-face span in that direction and the pitch.
- Enter the documented dead and transient roof pressures on the horizontal projected area. Set the transient deflection divisor for the comparison.
- Enter actual width, depth and on-center spacing for each rafter candidate. Use adjusted bending and modulus values from the project documentation.
- Read the projected span diagram and compare the two modeled span limits. Inspect the bending stress, transient deflection and margin at the entered span.
- Download the shared measurements, inputs and both check results as CSV.
The Formula
The mathematical logic powering this calculation is:
American Wood Council 2021 STJR section 5 defines the rafter span as the horizontal projection of the face-to-face support distance. With an along-slope measurement D and pitch r per 12, the worksheet uses projected span L = D / √(1 + (r/12)²). Use actual section dimensions b and d, and enter on-center spacing s in inches. The load basis is the horizontal projected area. Section modulus S = bd²/6 and second moment I = bd³/12.
For dead and transient pressures in pounds per square foot, total line load wt = (dead + transient) × s/144 and transient line load ws = transient × s/144, in pounds per projected inch. Enter one documented uniform design load case, with a transient value such as roof live or snow as specified for that case. Include member and assembly weight in the entered dead load as documented.
The AWC Appendix A.3.1 single-span bending check uses total load. Measured bending stress is wtL²/(8S) and the corresponding span limit is √(8F_b'S/wt), where F_b' is the applicable adjusted bending value. The immediate transient deflection is 5wsL⁴/(384EI). The entered limit L/k uses k as the divisor. The span at that limit is the cube root of 384EI/(5ws k). The weaker of the two checks supplies the lower modeled span limit. Two equal span limits are marked as a tie. Zero transient load leaves its deflection check inactive. Zero total load leaves both checks inactive. A zero-load case has no finite modeled cap.
Exact decimal arithmetic checks bending using L² and deflection using L⁶. When L comes from an inclined measurement, L² remains rational. Roots display the calculated lengths. A difference smaller than the displayed resolution still changes the exact state. The published AWC example uses a whole-inch table, while this worksheet retains the analytical endpoints for its two entered checks.
Enter 1–4,800 in for the active measured length, 0–24 pitch rise per 12, 0–2,000 psf for each pressure, and a whole deflection divisor of 1–2,000. Section width and depth are 0.125–120 in, on-center spacing 1–240 in, adjusted bending value 1–100,000 psi and modulus 1,000–10,000,000 psi. Decimal inputs allow six places. The ideal single-span model assumes uniform load and applicable lateral restraint. Enter already documented bending, stiffness, load and limit values. The two calculations exclude shear, bearing, connection checks, axial force, drift, creep, overall structural stability, actual roof geometry constraints, and code approval.Worked Example
If you input:
- Projected face-to-face span: 156 in. The illustrative 9:12 pitch gives an along-slope measurement of 195 in.
- Uniform pressures: 10 psf dead and 20 psf transient on the horizontal plan. Transient limit L/240.
- Both actual sections: 1.5 × 5.5 in at 16 in on center, modulus 1,350,000 psi.
- Adjusted bending values: Candidate A uses the AWC worked-example value of 1,400 psi. Candidate B compares an illustrative 1,000 psi.
Result:
Both candidates develop 1,340.82645 psi of bending stress and 0.61037 in of immediate transient deflection versus a 0.65 in limit. For A the lower modeled span is 159.30575 in, governed by transient deflection. Its whole-inch value agrees with the AWC worked example's 13 ft 3 in table result. B exceeds its bending limit of 134.72194 in while meeting the transient deflection limit.
Frequently Asked Questions
Which rafter length should I use for a span comparison?
Use the distance between support faces. The modeled span is its horizontal projection. You can enter that projection directly or provide the matching along-slope distance with pitch. Overhang, ridge deductions and stock cut allowances are separate layout quantities.
Why are there two span limits?
Uniform-load bending uses the dead and transient pressures together. The immediate transient deflection check uses the transient pressure alone and your entered L/divisor. The lower endpoint shows which of these two checks would reach its input first.
Where do the adjusted bending and stiffness values come from?
Enter applicable documented values for your actual material, member and load case. The worksheet applies the values you supply and does not look up grades or apply service, duration, restraint or repetitive-member adjustment factors.
Why does zero transient pressure leave deflection inactive?
The model checks the immediate deflection caused by the selected transient load. With zero transient pressure that modeled response is zero and has no finite inverse span limit. Dead load can still create bending and deflection that require other checks.
How does this compare with a published rafter span table?
The shared example uses the documented values from AWC's 2021 worked example. Published tabulated spans can be rounded and may include additional applicability assumptions. This worksheet reports the analytical limits of its two modeled checks at the entered values.
Why can two displayed spans appear equal when the result says exceeds?
The displayed roots are rounded. The check compares equivalent exact powers of the accepted values. The boundary preset lets you move just below or above a 144 in projected deflection limit and see the state change.
Can I use these results as approval for a structural layout?
The calculator provides two checks for an idealized rafter under the stated loads. A qualified structural review also considers applicable load combinations, material, shear, bearing, lateral stability, connections and building requirements.
Similar Calculators
Rafter Length & Stock Planner
Visualize common-rafter cuts, ridge deduction, overhang and birdsmouth geometry. Compare full layout blanks with stock lengths and prices; export measurements and coordinates.
Beam Response Calculator
Calculate beam reactions, shear force, bending moment, slope and deflection. Inspect load jumps and analytical extrema for simple supports or a cantilever.
Roof Area Calculator
Plan shed, gable and hip roof area, faces and edges. Compare roofing, underlayment, starter and cap quantities with exact whole-pack purchasing, diagrams and CSV.
Decking Joist Layout & Board Angle Planner
Check measured deck joist spacing against two entered limits. Compare diagonal board travel, exact bay widths and an equal-split layout.
Snow Load Calculator & Water Equivalent Planner
Compare estimated snow load and water equivalent across roof zones. Use direct measurements or layered depth and density ranges and see where local estimates exceed your comparison line.