Plantation Shutters Cost Calculator & Opening Fit

Translate three widths and three heights into an inside- or outside-mount sizing basis. Check two written panel and frame offers against the same opening, then compare how the minimum billable area and per-panel charges affect the installed total.

Inside and outside mount

Match shutter panels to measured openings

Quote B is $32.00 lower.

Quote A entered total
$1,320.00
Passes entered fit checks
Quote B entered total
$1,288.00
Passes entered fit checks
Open the measured opening

Written shutter offers

Changing the mount keeps the entered figures. Check that your quote’s terms apply to that mount.

Edit Quote A
Edit Quote B

Which measurements control?

The smallest width and height control. The centered sketch shows measured spans, with a heavier line for each controlling measure.

Opening basis · 48 in wide by 60 in high.

Compare equal-panel layouts

Both frames use one scale. The blank sides represent the combined frame reserve split evenly for this sketch.

A · 2 panels
22 in each · Passes entered fit

B · 2 panels
22 in each · Passes entered fit

Fit and charge ledger

Quote A fit

  • Unobstructed depth · Pass (5/2 measured, 9/4 limit)
  • Diagonal difference · Pass (1/16 measured, 1/8 limit)
  • Panel count · Pass (2 measured, 4 limit)
  • Minimum equal panel width · Pass (22 measured, 12 limit)

Quote B fit

  • Unobstructed depth · Pass (5/2 measured, 5/2 limit)
  • Diagonal difference · Pass (1/16 measured, 1/4 limit)
  • Panel count · Pass (2 measured, 4 limit)
  • Minimum equal panel width · Pass (22 measured, 12 limit)
Charge basisQuote AQuote B
Finished frame47.75 in × 59.75 in47.875 in × 59.875 in
Panel span44 in44 in
Finished area (ft²)19.81293419.906359
Billed area each (ft²)2022
Area charge each$560.00$539.00
Panel charge each$40.00$60.00
Fixed project charge$120.00$90.00
Entered installed total$1,320.00$1,288.00

Copyable shutter quote data

How to use this calculator

  1. Choose the mount and record the three widths and heights for the same aperture.
  2. Check the unobstructed depth and diagonals for an inside mount, or the narrowest usable flat trim for an outside mount.
  3. Enter the supplier’s full-axis allowance, frame reserve, panel range and maximum count for each quote.
  4. Enter each supplier’s rate, minimum billable area, panel fee and fixed project fee. Confirm matching covering and installation scope.
  5. Inspect how each frame splits into panels. Check the failing limit, charge ledger or downloadable exact values before comparing quotes.

The Formula

The mathematical logic powering this calculation is:

Use the smallest measured width and height for the inside mount and the largest for the outside mount. Measure depth to the nearest obstruction for the inside mount. For the outside mount, enter the narrowest usable flat trim around the opening. For the inside square check, take the absolute difference between the two measured diagonals and compare it with each written limit.

Apply only the allowance confirmed in that written quote, once per full opening axis. Subtract the entered allowances for inside mount and add them for outside mount. From the adjusted frame width, subtract the written total width occupied by the frame and gaps. The result is the equal-panel span. Divide by the quote's maximum panel width and round up to the lowest whole panel count. Panel width equals span divided by count. The count cannot exceed the written maximum, and the panel width cannot go below the written minimum. Exact bounds are included.

Finished frame area equals adjusted width × adjusted height ÷ 144. Bill the larger of this area and the written per-opening minimum. Multiply by the rate and round that one opening’s area charge to cents, half-up. Add the panel count times the per-panel charge. Multiply the per-opening total by the entered count of identical confirmed openings and add fixed project charges once.

This compares equal hinged rectangular panels only. Use the same covering and installation scope for both quotes. Quote prices are shown for audit, and a winner requires confirmed matching scope and the entered fit checks to pass for both quotes. It does not provide installation instructions, standard allowances, custom shape sizing or a substitute for supplier confirmation. Changing the mount mode changes the measurement rule and the meaning of the quoted adjustments.

Dimensions enter in inches with up to four decimals. Widths and heights may be 0.0001–240 in, diagonals 0.0001–400 in, clearances and adjustments 0–30 in, frame reserve 0–60 in, and written panel widths 0.0001–120 in. Enter up to 40 confirmed identical openings and up to 12 panels per quote. The minimum billable area allows 0–500 ft² with up to four decimals. USD amounts allow 0–1,000,000 with up to two decimals.

Worked Example

If you input:

  • Mount and quantity: Inside mount, two verified identical openings
  • Width readings: 48.25, 48 and 48.125 in
  • Height readings: 60.125, 60 and 60.0625 in
  • Recess and diagonals: 2.5 in recess, 76.875 and 76.8125 in diagonals
  • Quote A and B minimum areas: 20 and 22 ft² per opening

Result:

A 48 in by 60 in opening basis gives two equal 22 in panels in both quotes. Quote A totals $1,320 and Quote B totals $1,288. At 2.375 in of clear depth, Quote B misses its 2.5 in requirement.

Frequently Asked Questions

Why are the measured opening and finished frame sizes different?

Suppliers use different allowances for their frames. Enter the adjustment written for the full axis. The workbook does not apply an additional default adjustment.

How does it handle a window that is out of square?

Inside mount compares the two measured diagonals with the quote's stated maximum difference. The diagram uses the recorded spans as a schematic. It cannot establish actual corner coordinates.

Will the two offers always have the same number of panels?

No. The frame reserve and maximum panel width can differ. The worksheet chooses the lowest equal-panel count allowed by that width, then checks the vendor’s count and minimum-width bounds.

Why can a smaller finished frame cost more?

A written minimum billable area may exceed the true frame area. Panel fees and project charges add to the quoted area charge.

Can I group several different window openings?

The quantity multiplier is for openings with verified matching measurements and scope. Calculate different openings independently. Apply only the proper shared charge once in a combined written offer.

Similar Calculators