PCB Trace Resistance & Voltage Drop Calculator
Define up to six in-series trace segments and two possible trace-width layouts for the same lengths. Match your fabrication thickness and width allowances to estimate worst dimensional DC resistance. Trace diagrams and cumulative drop show which sections use the entered voltage budget.
Compare two PCB trace voltage-drop profiles
See how neckdowns and entered fabrication dimensions use the same DC voltage budget.
Edit common path and nominal widths
Edit electrical inputs and fabrication bounds
Layout A · 32.5 mΩ worst resistance
65 mV
52.083333 mV nominal · 130 mW worst loss
0 mV budget headroom · 2 A at budget
Layout B · 27.5 mΩ worst resistance
55 mV
45.454545 mV nominal · 110 mW worst loss
10 mV budget headroom · 2.363636 A at budget
Inspect the trace and cumulative drop
Cumulative worst drop (mV)
- Layout A
- Layout B
- Drop budget
Segment 2 · 20 to 25 mm
Layout A · 0.25 mm minimum width
10 mΩ · 20 mV here · 40 mV cumulative
Layout B · 0.5 mm minimum width
5 mΩ · 10 mV here · 30 mV cumulative
Review exact segment ledger
| Layout | Segment | Minimum width (mm) | Worst resistance (mΩ) | Worst drop (mV) | Cumulative (mV) |
|---|---|---|---|---|---|
| A | 1 | 1 | 10 | 20 | 20 |
| A | 2 | 0.25 | 10 | 20 | 40 |
| A | 3 | 1 | 12.5 | 25 | 65 |
| B | 1 | 1 | 10 | 20 | 20 |
| B | 2 | 0.5 | 5 | 10 | 30 |
| B | 3 | 1 | 12.5 | 25 | 55 |
The ledger displays fractions when a rounded decimal would lose precision.
How to use this calculator
- Enter the measured conductor temperature, copper resistivity basis, DC current and voltage-drop allowance.
- Enter each common segment length and the two nominal widths, keeping serial route order.
- Enter documented nominal and minimum copper thickness and width loss per edge for each proposal.
- Inspect the width strips and the cumulative drop at each segment. Open the exact ledger and download the complete comparison.
The Formula
The mathematical logic powering this calculation is:
Use the same lengths, reference resistivity, trace temperature, steady DC current and voltage-drop budget for both layouts. Adjust the entered reference resistivity at 20 °C by multiplying it by 1 + α(T − 20). Use an applicable measured or documented linear temperature coefficient in reciprocal °C. The example coefficient is the NIST standard annealed copper reference, with illustrative reference resistivity.
For a rectangular segment, resistance is adjusted volume resistivity times length divided by cross-sectional area. Enter resistivity in nΩ·m, length and width in mm and copper thickness in µm to obtain mΩ. Width loss per edge is in µm. Modeled minimum width equals nominal width minus twice that loss converted to mm. This gives the dimensional upper resistance from minimum width and minimum copper thickness. Width must stay positive.
Add segment resistances in series. Each drop is current times resistance, in mV, and each modeled DC loss is current squared times resistance, in mW. A cumulative drop exactly equal to the budget fits. If an endpoint exceeds it, uniformly interpolate the budget crossing inside that first segment. Budget-limited current equals budget divided by the worst dimensional trace resistance, independent of the entered operating current.
Use 1–6 positive segment lengths of 0.001–10,000 mm, nominal widths of 0.001–1,000 mm, and thicknesses of 0.001–1,000 µm. Width loss accepts 0–10,000 µm per edge. Resistivity is 0.001–1,000 nΩ·m, temperature −40–180 °C, current 0–1,000 A and the budget 0–1,000,000 mV. Use up to three decimals for these inputs, and six decimals for a linear coefficient between 0 and 0.01 per °C. All comparisons and CSV data use exact rational arithmetic.
This applies to a series-only stack of rectangular copper sections with uniform entered temperature and concurrent dimensional lows. It does not model plated vias, transitions, current crowding, return loss, self-heating, conductor ampacity, board spacing rules or high-frequency impedance. The current derived from the entered drop budget is a voltage-drop calculation.Worked Example
If you input:
- Common lengths: 20, 5 and 25 mm
- Layout A / B neck width: 0.30 mm / 0.55 mm nominal
- Copper stack: 40 µm nominal, 35 µm minimum, 25 µm per-edge width loss
- Budget and load: 65 mV at 2 A and 20 °C
Result:
Worst dimensional voltage drops are 65 mV for Layout A and 55 mV for Layout B. A fits exactly. Reducing A's neck by 0.001 mm gives about 65.080321 mV and only Layout B fits.
Frequently Asked Questions
Why enter width loss per edge?
A loss on each edge contributes to the total width reduction. Enter half a documented symmetric total width loss, or enter half the sum of two documented edge losses for this rectangular model.
Does the worksheet choose a safe current?
The reported current is the budget divided by modeled resistance. The model does not evaluate ampacity, board heating or other operating constraints.
Why is a narrow segment significant even if it is short?
For unchanged length and thickness, resistance varies inversely with width. A short narrow section can use the same budget as a much longer wide one.
What if different segments have different via stacks?
This model uses a single thickness pair and edge allowance per layout. Element-specific via and junction resistances require a separate path analysis.
Similar Calculators
Four-Wire Resistivity & Conductivity Calculator
Find bulk resistivity and conductivity from two measured four-wire runs. Remove a constant voltage offset and compare exact uncertainty bands at one temperature.
12V DC Shared Feeder Wire Sizing Calculator
Compare three 12V DC cable options in a shared feeder and two branches. See terminal voltage, current margins and the cheapest qualifying wire combination.
DC Voltage Drop & Cable Loss Calculator
Compare DC cable voltage drop, power losses and load limits with separate conductor lengths, connection resistance, constant-power loads and visual sweeps.
Coplanar Waveguide Calculator & Impedance Window
Estimate coplanar transmission line impedance across two documented width and gap windows. Inspect the geometry corners that set each impedance bound.