Coplanar Waveguide Calculator & Impedance Window

Compare two symmetric, unbacked coplanar waveguide layouts using documented trace width and gap ranges and one dielectric. The calculator identifies the geometry corners that give the smallest and largest modeled impedance and compares the complete ranges with your target.

Symmetric unbacked coplanar line

Compare coplanar waveguide impedance ranges

Edit substrate, target and layout dimensions

Enter the gap on one side. The model uses the same gap on both sides of the trace.

Layout A
Layout B

Only Layout A fits the full impedance window.

Effective permittivity 2.6 · Target 46.7 to 50.320449 Ω

Layout A

Entire modeled range fits

Modeled impedance across dimension range

46.799138277 to 50.320448591 Ω

Impedance at midpoint dimensions

48.551138512 Ω

Layout B

Only part of modeled range fits

Modeled impedance across dimension range

46.291196406 to 50.999592721 Ω

Impedance at midpoint dimensions

48.551138512 Ω

Compare impedance with the entered target

Layout ALayout B
45.628 Ω51.663 Ω
  • Target 46.7 to 50.320449 Ω
  • Inspected geometry

Inspect the trace and gaps

Symmetric section across the trace

  • Trace
  • Gap
  • Coplanar grounds
  • Substrate

Widths share one scale. Metal and substrate thickness are schematic.

Layout A · Midpoint dimensions

Trace 1,000 µm

Gap on each side 100 µm

48.551138512 Ω · Within entered target

Review the bounded impedance ledger
Width, gap and model impedance enclosures
Layout and geometryTrace (µm)Gap (µm)Lower bound (Ω)Upper bound (Ω)
A · Lowest impedance10509046.79913827733346.799138277334
A · Midpoint dimensions100010048.55113851178048.551138511781
A · Highest impedance95011050.32044859137450.320448591375
B · Lowest impedance11009046.29119640627046.291196406271
B · Midpoint dimensions100010048.55113851178048.551138511781
B · Highest impedance90011050.99959272086550.999592720866

How to use this calculator

  1. Enter a representative documented substrate permittivity and your target impedance band.
  2. Copy the minimum and maximum center trace width and symmetric gap for each layout, in micrometers.
  3. Compare both modeled windows with the target. Select a profile and geometry corner to inspect the strip and gap.
  4. Review the numerical bounds and export the worksheet for comparison with further validation.

The Formula

The mathematical logic powering this calculation is:

Use the symmetric conventional coplanar waveguide with a center strip of width w and two equal gaps g. The top medium is air, the substrate is taken as infinitely thick and there is no backside conductor. Use εeff = (1 + εr)/2. Let k = w/(w + 2g), k′ = √(1 − k²), and Z = 30πK(k′)/(√εeff × K(k)). K is the complete elliptic integral of the first kind. The formula is the quasi-static thin-conductor model.

At a fixed dielectric, impedance decreases when the strip widens or the gap narrows. With independently entered width and gap intervals, the minimum is at largest width and smallest gap. The maximum is at smallest width and largest gap. The comparison uses those two corners; the midpoint-dimensions estimate uses the midpoint of each dimension.

The elliptic ratio equals AGM(1,k′)/AGM(1,k). Directed integer arithmetic at 30 decimal places encloses both means and the square roots. A 30-place enclosure for π gives rational lower and upper bounds through the calculation. Entire containment, disjointness and partial overlap are reported only when certified by those bounds. Target endpoints are included. When the numerical enclosure cannot decide a boundary, the result is unresolved. The displayed values are rounded. CSV impedance columns are rounded outward to 12 decimal places.

Enter dielectric εr from 1 to 1,000, width and gap intervals from 0.001 to 10,000 µm, and target impedance limits from 0 to 10,000 Ω. Inputs allow six decimals. This model covers a uniform, lossless, symmetric section with negligible conductor thickness and effectively broad coplanar grounds. Finite substrate, backside copper, plating, solder mask, local roughness, dispersion and fabrication correlations can change the actual impedance.

Worked Example

If you input:

  • Substrate relative permittivity: 4.2
  • Target: 46.7–50.320449 Ω
  • Layout A: 950–1,050 µm strip, 90–110 µm gaps
  • Layout B: 900–1,100 µm strip, 90–110 µm gaps

Result:

Both centered layouts have about 48.551139 Ω at their midpoint dimensions. A spans about 46.799138–50.320449 Ω and fits the full target band. B has a wider span, about 46.291196–50.999593 Ω, so only part of it fits.

Frequently Asked Questions

Does the gap refer to both spaces added together?

Enter one side’s gap. The symmetric model uses that same separation on both sides.

Why can the midpoint impedance match while the range result differs?

Two layouts can share midpoint dimensions but have a different permitted trace or gap spread. Those spreads reach different endpoint impedances.

Why can a wider trace lower impedance?

It raises the geometry ratio w/(w + 2g). In the conventional coplanar formula the elliptic ratio falls as that ratio increases.

Does this work for grounded coplanar waveguide?

Use the model for unbacked CPW. A conductor under the substrate changes the electromagnetic boundary.

How should I interpret the numerical enclosure?

It covers calculation error for the chosen ideal model. It does not cover stackup, measurement or modeling errors outside the inputs.

Similar Calculators