Series RLC Step Response & Ringdown Calculator

Use the same inductance, capacitance and initial state for two series resistances. Compare the time responses, inspect the exact damping classifications and probe either response at a chosen time. Switch from voltage and current to stored energy relative to the constant-source equilibrium.

Series RLC

Compare two RLC transients

Edit circuit and initial state

Enter the total resistance of each modeled loop. Positive current flows into the capacitor’s positive reference plate.

At 1 ms

Critical resistance 20 Ω

Plan A · 6 Ω

Underdamped

1.90708 V

Current
316.732 mA
Energy about equilibrium
0.979902 mJ

Plan B · 20 Ω

Critically damped

1.32121 V

Current
183.94 mA
Energy about equilibrium
0.845846 mJ

Transient response

Showing 0 to 8 ms.

Voltage response of the two RLC plansThe graph covers zero to 8 milliseconds. Solid teal is plan A and dashed violet is plan B. The probe is at 1 milliseconds.Voltage (V)003.7747.558Time (ms)
Plan APlan B
Select transient CSV

How to use this calculator

  1. Enter shared inductance, capacitance, final source voltage, initial capacitor voltage and initial loop current. Use a zero source for source-free ringdown.
  2. Enter the two total series resistances, including any modeled resistance you want the loop to contain.
  3. Choose a probe time and requested graph window. Compare the voltage, current and energy at the same time for both plans.
  4. Switch the chart's quantity to inspect the waveform or energy. Use Early transient to magnify the fast decay where supported.
  5. Download the requested probe and charted samples as CSV. A long oscillatory probe can exceed the numerical phase limit.

The Formula

The mathematical logic powering this calculation is:

Take current positive into the capacitor's positive reference plate, so I = C·dV/dt. For a constant final source E, define u = V−E. Kirchhoff's voltage law gives u'' + 2αu' + ω₀²u = 0, with α = R/(2L), ω₀² = 1/(LC), u(0) = V₀−E and u'(0) = I₀/C. For ideal R = 0 the solution is undamped. Otherwise the sign of R²C−4L identifies underdamping, exact critical damping or overdamping. This sign is evaluated before rounding from the entered decimal component values.

Let Δ = α²−ω₀². In the underdamped case the displacement uses cos(√−Δ·t) and sin(√−Δ·t)/√−Δ times exp(−αt). The repeated-root solution uses exp(−αt)[u(0)+(u'(0)+αu(0))t]. The overdamped case uses the two negative roots −α±√Δ. The slow root is evaluated through the product of the roots to avoid subtracting nearly equal rates under heavy damping. Near repeated roots the implementation uses the continuous hyperbolic form for short enough arguments. Very early samples use a convergent local series to preserve small step changes. Current is the analytic derivative times C.

Energy about equilibrium is ½C(V−E)² + ½LI². For zero source it is actual stored capacitor and inductor energy. For a constant nonzero source it measures displacement from equilibrium, and its derivative is −RI². This is not total source energy.

The plotted window contains at most eight cycles of the fastest oscillatory plan. Early transient can also limit the chart to eight fast time constants. A few extra samples resolve fast decay near t=0. These plot limits leave the independent time probe unchanged. An oscillatory probe beyond a phase angle of 100 million radians is unavailable. Sample positions and trajectory calculations use double precision. This is an ideal linear model for fixed components and a constant source after the step.

Enter L and C from 0.001 through 100,000 mH and µF respectively, R from 0 to 1,000,000 Ω, signed source and initial voltages up to 1,000 V in magnitude, signed initial current up to 100,000 mA and times through 60,000 ms. A requested plot must have positive length. Enter decimal values with up to six places. These are numerical input bounds. The worksheet leaves physical ratings, wiring, switching behavior and nonideal components to separate analysis.

Worked Example

If you input:

  • Shared components: 10 mH and 100 µF
  • Source and initial state: 5 V final source, 0 V initial capacitor, 0 mA initial current
  • Series resistances: 6 Ω and 20 Ω
  • Probe: 1 ms

Result:

Critical resistance is 20 Ω. At 1 ms the underdamped 6 Ω plan has 1.90708 V on the capacitor and 316.732 mA. The critically damped 20 Ω plan has 1.32121 V and 183.940 mA.

Frequently Asked Questions

What changes when resistance crosses the critical value?

Under critical resistance the natural response has a decaying oscillatory factor. At critical resistance the roots coincide. Above it the response is a sum of two decaying real exponential terms.

Which direction is positive current?

Positive current enters the positive reference plate of the capacitor and increases the modeled capacitor voltage.

How do I enter a source-free ringdown?

Set the final source to zero and enter the initial voltage or current to represent stored energy. An ideal zero-resistance plan keeps oscillating.

Why does plotted energy depend on the final source voltage?

It describes the displacement from equilibrium. For nonzero final source it excludes the static background energy of the charged equilibrium capacitor.

Why can the chart stop before my requested time?

The plot bounds the fastest oscillation to eight cycles and can zoom into fast decay. The separate probe still evaluates later times within the stated phase range.

What resistance should I enter?

Use the total resistance you intend to model in the series loop. The worksheet does not infer losses or parasitic effects from the other component values.