Wall Thermal Bridge & Heat Loss Calculator

Start with a documented clear-field U-factor for the opaque wall. Add two documented linear junctions and a repeated point detail, then compare total steady heat flow, equivalent U- and R-values, and the remaining junction allowance under an entered limit.

Opaque wall heat flow

See what junctions add to wall heat loss

Both walls are within the entered heat loss limit.
Wall A · Heat loss
700 W
0.35 W/(m²·K) effective U · Within limit
Wall B · Heat loss
550 W
0.275 W/(m²·K) effective U · Within limit
Heat loss by transmission path

Each bar uses the same scale. The vertical marker is the 700 W limit.

Wall A · 700 W

Clear field
600 W
Junction 1
80 W
Junction 2
0 W
Point details
20 W

Wall B · 550 W

Clear field
450 W
Junction 1
80 W
Junction 2
0 W
Point details
20 W
Shared wall and heat loss conditions
Wall A documented details
Wall B documented details
Review conductance and CSV
Whole wall conductance and exact target margins
AssemblyTotal (W/K)Effective U (W/m²·K)Effective R (m²·K/W)Loss (W)Limit margin (W)
Wall A350.352.85717000
Wall B27.50.2753.6364550150

How to use this calculator

  1. Enter the net opaque area, temperature difference and relevant heat loss limit.
  2. Enter each wall's documented clear-field U-factor, two junction lengths and ψ values, and the count and χ value for repeated point details.
  3. Compare the stacked heat flows and check the maximum ψ for junction 1 at the entered target.
  4. Open the conductance ledger or download both complete wall cases as CSV.

The Formula

The mathematical logic powering this calculation is:

For each assembly calculate clear-field conductance H₀ = A × U₀ in W/K, using net opaque area A and the clear-field U-factor including repeating framing where applicable. For each linear junction add length L × its documented linear transmittance ψ. For the point detail add the count times the documented per-detail transmittance χ. Total conductance H = H₀ + L₁ψ₁ + L₂ψ₂ + count × χ.

The effective U-factor is H/A and the effective thermal resistance in SI is A/H. Use the same entered positive temperature difference magnitude for both comparisons. Steady conductive heat loss is Q = H × ΔT. The target margin is the entered limit minus modeled heat loss. Exact equality qualifies.

To find the largest nonnegative ψ₁ allowed by the stated limit, subtract the modeled watts from the clear field, junction 2 and the points from the limit. Divide the remaining watts by L₁ × ΔT if this product is positive. A negative remainder means the modeled other paths already exceed the limit. With zero length or zero temperature difference, junction 1 cannot alter this case.

Use a consistent area and reference convention for clear-field, linear and point data so each bridge is accounted for once. This worksheet covers nonnegative additive junction corrections and one temperature difference. It does not derive ψ from cross-sectional geometry, estimate surface temperatures, model air leakage, or replace whole-building energy or compliance analysis.

Areas are 0.000001–1,000,000 m², the temperature difference 0–200 K and the entered limit 0–100,000,000 W. U-factors are 0.000001–100 W/(m²·K), junction lengths 0–100,000 m, ψ and χ 0–100 in their respective units, and point counts 0–100,000 whole details. Up to six decimal places and exact rational calculations are supported. The CSV retains exact fractions.

Worked Example

If you input:

  • Opaque area: 100 m² and 20 K temperature difference
  • Wall A: U₀ 0.300 W/(m²·K)
  • Wall B: U₀ 0.225 W/(m²·K)
  • Bridge terms: 20 m at ψ 0.200 W/(m·K) and 2 details at χ 0.5 W/K

Result:

Wall A reaches the 700 W limit exactly and B reaches 550 W. Raising Wall A's ψ to 0.201 W/(m·K) increases its loss to 700.4 W.

Frequently Asked Questions

Do the entered bridge details include every stud?

Repeating framing generally belongs in the clear-field U-factor. Use separate line and point entries only for additional effects measured against the same reference.

Should I enter window area in this wall calculation?

Use the net opaque wall area. Window and door through-area heat flows are separate from documented additive perimeter effects.

Why does a zero-length junction have no maximum ψ?

Its contribution is length times ψ, so changing ψ at zero length cannot change heat loss. Zero temperature difference has the same effect in the selected case.

Does the maximum junction value establish a suitable detail?

It is the heat-flow threshold with the other inputs held fixed. Obtain actual detail transmittance and assess the assembly using the applicable design and measurement methods.