Stormwater Runoff & Detention Storage Calculator
Model one rainfall sequence over several measured surfaces. Compare the rising and falling water volumes under two simplified storage options, find the exact time when overflow begins, and review the capacity that would contain the modeled event.
Compare stormwater runoff and storage during a rain event
Enter measured surface areas and rainfall intervals. Follow the water through two storage options.
Block width is elapsed time. Height is runoff rate during each interval.
1,920 L from 12 mm of entered rain across 250 m². The weighted contributing area is 160 m².
Compare stored volume on the same scale. A diamond marks the first modeled overflow.
Storage A
1,000 L peak of 1,000 L usable
No overflow
Storage B
800 L peak of 1,000 L usable
No overflow
Enter the total depth of rainfall for each interval in time order.
120 L remains at event end. The outlet empties it in 2 min if rain stops.
0 L remains at event end. Storage is already empty.
Review interval balances and exact CSV
| Option and interval | Ends at | Runoff inflow | Outlet volume | End storage | Overflow |
|---|---|---|---|---|---|
| Storage A · 1 | 10 min | 1,600 L | 600 L | 1,000 L | 0 L |
| Storage B · 1 | 10 min | 1,600 L | 800 L | 800 L | 0 L |
| Storage A · 2 | 30 min | 320 L | 1,200 L | 120 L | 0 L |
| Storage B · 2 | 30 min | 320 L | 1,120 L | 0 L | 0 L |
How to use this calculator
- Enter the measured contributing areas and the runoff fraction you want to assume for each surface.
- Add the rainfall intervals in order using their measured total depth and duration. A zero-depth interval helps represent a pause or drainage period.
- Copy the usable capacity, starting contents and assumed maximum outlet flow for each storage option.
- Inspect the runoff and storage plots, review the interval balance, and download the exact ledger.
The Formula
The mathematical logic powering this calculation is:
For each contributing surface multiply its measured area by its entered runoff fraction and add the weighted areas. Each millimetre of rainfall over one square metre gives one litre. For interval depth d, modeled inflow is d times the total weighted area. Divide by the interval duration for a constant inflow rate. Use the same entered fractions throughout the event.
For each storage option, add initial volume and route the intervals in order. While water is available, it leaves the outlet at the entered maximum rate. At empty storage, outlet flow is limited to inflow. At full storage, any positive inflow above outlet flow leaves as overflow. On a rising interval, time to reach full storage equals unused capacity divided by inflow rate less outlet rate. Exact contact with the capacity at the end of an interval does not spill water. The ledger reconciles inflow plus prior storage with new storage, outlet discharge and overflow.
Minimum no-overflow capacity is the highest modeled stored volume in a separate rerun with the upper limit removed and the same initial amount and outlet rate. This preserves water that spilled in the limited case. Dry drain time uses the final stored volume divided by the outlet rate. With a closed outlet, a nonempty basin does not drain in the model.
Enter one to six distinct surfaces (0.001–100,000 m² each), and one to eight chronological intervals with 0.001–1,440 minutes and 0–1,000 mm per interval. The model assumes instantaneous delivery, uniform rainfall within each interval, a fixed runoff fraction and an idealized constant-flow outlet. It leaves out travel time, head-dependent discharge, infiltration changes, backwater, connected structures and other hydraulic effects. It compares entered assumptions rather than qualifying a real drainage design.Worked Example
If you input:
- Surfaces: 150 m² at runoff fraction 0.90 and 100 m² at 0.25
- Rainfall: 10 mm over 10 minutes, followed by 2 mm over 20 minutes
- Storage: Two empty 1,000 L options. A discharges up to 60 L/min and B up to 80 L/min.
Result:
Runoff is 1,920 L. A reaches 1,000 L exactly and B reaches 800 L. Neither option spills under the example assumptions.
Frequently Asked Questions
How do I enter rainfall intensity instead of interval depth?
Multiply the average intensity in millimetres per hour by the duration in hours. Enter that total depth in the interval row.
Why can two events with the same rainfall give different overflow?
Intervals with more intense rainfall deliver the same volume over less time. An outlet may discharge more of the runoff before capacity is reached when rain arrives more gradually.
Why is the no-overflow capacity shown separately?
The actual storage trace discards spilled water. The counterfactual retains it, so its peak can be larger than the highest stored volume in the limited case.
What if storage reaches full capacity at the end of a step?
At exact equality, there is no overflow for that step. A subsequent interval can spill at its start if inflow exceeds available outlet flow.
Does this replace routing with a stage-discharge curve?
The worksheet assumes a supplied fixed outlet limit. A hydraulic model can account for stage-dependent outlet flow, catchment timing and downstream conditions.
Similar Calculators
Impervious Surface Coverage Calculator
Compare parcel surface layouts, calculate weighted impervious coverage, and see the remaining area budget against your entered coverage limit.
Gutter Sizing & Rainfall Capacity Calculator
Compare gutter and downpipe ratings against roof rainfall demand, outlet layout and available fall. Explore capacity headroom, product alternatives, rainfall plots and CSV.
Well Yield, Pump Flow & Cistern Buffer Calculator
Check whether measured well yield, pump transfer and usable cistern storage can cover timed demand. Compare two plans with exact storage and shortfall histories.
Roof Rainwater Harvesting & Drawdown Calculator
Calculate rainfall collected from a roof after first flush, compare two usable tank sizes through four events, and find the minimum storage for planned water use.