Roof Rainwater Harvesting & Drawdown Calculator
Track roof rainwater through four rain or dry-use events with the same starting water and two usable tank sizes. See exactly how much is diverted, captured, spilled and delivered. Find the smallest usable tank that could cover every entered withdrawal, or see how much starting water the schedule requires.
Compare roof rainwater storage
Calculate first-flush losses, follow two tank levels and find the smallest usable volume that covers your planned withdrawals.
Edit catchment, tanks and event sequence
Use the roof’s horizontal area feeding the tank and the collection fraction before first flush.
Enter rain and use in time order. Each row adds rain before the withdrawal. Set both values to zero for unused rows.
Only tank A covers every planned withdrawal.
Usable storage threshold
- Minimum usable capacity with entered start
- 140 L
- Minimum starting water at any tank size
- 0 L
This threshold covers every entered withdrawal. Extra rain can still spill.
- Captured across the sequence
- 200 L
- Planned use across the sequence
- 200 L
Tank A · 140 L
Every withdrawal covered
- Delivered
- 200 L
- Unmet use
- 0 L
- Overflow
- 0 L
- Ending water
- 0 L
Tank B · 139.999 L
First shortfall at event 4
- Delivered
- 199.999 L
- Unmet use
- 0.001 L
- Overflow
- 0.001 L
- Ending water
- 0 L
Inspect a rain or use event
Tank level through the four events
Liters in storage
- Tank A
- Tank B
- Needed after rain
Squares show the amount after rain. Circles show water left after use. Read the event details for exact amounts.
Event 1
- First-flush bypass
- 20 L
- Net capture
- 140 L
- Planned use
- 40 L
- Needed just after rain
- 140 L
Tank A
- After rain
- 140 L
- Overflow
- 0 L
- Unmet use
- 0 L
- After use
- 100 L
Tank B
- After rain
- 139.999 L
- Overflow
- 0.001 L
- Unmet use
- 0 L
- After use
- 99.999 L
Review the exact event ledger
| Event and tank | First flush | Net capture | Use | After rain | Overflow | Unmet | After use |
|---|---|---|---|---|---|---|---|
| 1 · Tank A | 20 L | 140 L | 40 L | 140 L | 0 L | 0 L | 100 L |
| 1 · Tank B | 20 L | 140 L | 40 L | 139.999 L | 0.001 L | 0 L | 99.999 L |
| 2 · Tank A | 0 L | 0 L | 50 L | 100 L | 0 L | 0 L | 50 L |
| 2 · Tank B | 0 L | 0 L | 50 L | 99.999 L | 0 L | 0 L | 49.999 L |
| 3 · Tank A | 20 L | 60 L | 40 L | 110 L | 0 L | 0 L | 70 L |
| 3 · Tank B | 20 L | 60 L | 40 L | 109.999 L | 0 L | 0 L | 69.999 L |
| 4 · Tank A | 0 L | 0 L | 70 L | 70 L | 0 L | 0 L | 0 L |
| 4 · Tank B | 0 L | 0 L | 70 L | 69.999 L | 0 L | 0.001 L | 0 L |
How to use this calculator
- Enter the horizontal roof area feeding the tank, the collection fraction before first flush, and the first-flush volume allowed for each separate rain event.
- Enter shared starting water and two usable capacities. Add up to four rainfall and withdrawal pairs in time order, leaving unused rows at zero.
- Check the event where either tank spills or falls short, then read the exact usable capacity threshold and export the event ledger.
The Formula
The mathematical logic powering this calculation is:
Use the roof’s horizontal projected area that actually drains to the tank. Multiply area in square meters by rainfall in millimeters and the entered collection fraction. One millimeter over one square meter equals one liter. The collection fraction represents losses upstream of the entered first-flush diversion. If a measured fraction already includes first flush, set the first-flush entry to zero to avoid counting that loss twice.
For each separate rain event, the first-flush bypass is the smaller of the entered liters and the runoff after collection losses. The balance is captured. Enter zero rain for a dry-use event and zero use for rain without a withdrawal. Each row adds rain before making that row’s withdrawal. When use occurs before a shower, put that withdrawal on an earlier dry row. Rows are in chronological order. Each wet row assumes a fresh first-flush allowance, so one continuous storm belongs in one row if its bypass resets only once.
Each tank starts with the same usable water. Add capture to the water already in the tank, spill the amount above usable capacity, and serve the withdrawal from what remains. The ledger reports each tank’s overflow, water delivered, unmet use and ending volume separately. Equality at a capacity or withdrawal threshold counts as a fit.
Work backward through the four rows to find the minimum starting volume and tank size. Begin at the final row with zero required after use. Each row needs its own withdrawal plus the next row’s before-rain requirement immediately after rain. Subtract that row’s capture, flooring at zero, to get its before-rain requirement. The first before-rain requirement is the minimum starting water even with unlimited storage. With enough starting water, the smallest usable capacity is the larger of the entered starting water and the greatest after-rain requirement. This size can spill excess water and still cover all withdrawals.
Input values use up to three decimals. The water balance is exact to a nanoliter, so a small shortfall stays visible. The worksheet budgets nonpotable water volume over the entered sequence. It assumes no other losses or inflows from storage and no withdrawals between rows. Usable capacity is the amount you can actually withdraw. The result covers the entered sequence and does not assess water quality or future weather.Worked Example
If you input:
- Roof catchment: 100 m², collection fraction 0.8
- First flush: 20 L per rain event
- Initial water: 0 L
- Tank capacities: A 140 L, B 139.999 L
- Rain / planned use: 2 mm / 40 L, 0 / 50 L, 1 mm / 40 L, 0 / 70 L
Result:
Events 1 and 3 supply 140 L and 60 L after first flush. The smallest usable tank is 140 L. Tank B spills 0.001 L at event 1 and falls short by 0.001 L at event 4.
Frequently Asked Questions
Why use the horizontal roof area?
Rainfall depth is measured per unit of horizontal area. Include only the horizontal projection of the roof sections that drain into the modeled tank.
Can the tank spill while meeting all uses?
Yes. A large shower can exceed usable capacity even when all scheduled withdrawals fit. The minimum usable capacity is intended to avoid shortfalls, and may still allow overflow.
Can a bigger tank make up for rain that arrives too late?
The minimum starting water captures use that precedes available rain. If the entered start is below that amount, the sequence falls short at every tank size.
Can I enter a dry day?
Yes. Set rain to zero and enter the planned withdrawal. The tank can serve that use from whatever the previous row left in storage.
Does first flush happen on every row?
The entered diversion applies separately to each wet row, up to its available runoff. No runoff or bypass occurs when rainfall is zero.
Similar Calculators
Stormwater Runoff & Detention Storage Calculator
Turn measured rainfall intervals into a stormwater runoff volume and compare storage, outlet flow, and overflow under two entered basin options.
Well Yield, Pump Flow & Cistern Buffer Calculator
Check whether measured well yield, pump transfer and usable cistern storage can cover timed demand. Compare two plans with exact storage and shortfall histories.
Gutter Sizing & Rainfall Capacity Calculator