Spiral Stair Calculator & Walkline Geometry

Enter the total vertical rise and turn, inner and outer radii, and the radius at which to measure the walking path. Choose arc length or straight chord as the run measure. The worksheet checks each interval count against the rise and run limits you enter and shows the selected geometry in plan.

Spiral geometry and walkline

Compare spiral stair interval geometry

Enter the rise, total turn and walkline radius. See which equal intervals meet your stated rise and run limits.

15 intervals meet the entered limits.

16 intervals
Too short at walkline
Radial width
900 mm
Edit geometry and stated limits

One interval is the same rise and turn from one modeled station to the next. Use one length unit throughout.

Plan view at 16 intervals

Blue traces the first walkline arc. Amber joins its endpoints. Radial lines mark each interval boundary.
Turn per interval
22.5°
Rise per interval
175 mm
Walkline arc
255.254403 mm
Walkline chord
253.617419 mm

Margins across candidate counts

Green shows room under the rise limit. Blue dashes show the chord above the minimum. Positive margins are above the dark zero line.

12 intervalsInspecting 1619 intervals

Open candidate ledger
Candidate interval counts, dimensions and entered limit comparisons
IntervalsRiseArcChordStatus
12233.333333 mm340.339204 mm336.464759 mmToo much rise
13215.384615 mm314.159265 mm311.110364 mmToo much rise
14200 mm291.719318 mm289.277214 mmToo much rise
15186.666667 mm272.271363 mm270.285198 mmMeets entered limits
16175 mm255.254403 mm253.617419 mmToo short at walkline
17164.705882 mm240.239438 mm238.874373 mmToo short at walkline
18155.555556 mm226.892803 mm225.742631 mmToo short at walkline
19147.368421 mm214.951076 mm213.972967 mmToo short at walkline
Open selectable CSV

How to use this calculator

  1. Enter the total vertical rise and angular turn between your modeled endpoints.
  2. Enter the inside radius, outside radius and the measured walkline radius.
  3. Pick arc or chord and enter the largest rise and smallest run you want to compare.
  4. Set the lowest and highest candidate counts. Select a count to inspect in the plan view.
  5. Inspect both margins over the tested counts and export the candidate ledger.

The Formula

The mathematical logic powering this calculation is:

An interval means one equal vertical and angular increment between modeled stations. It is not an installed tread count. For total rise H, total turn T, and n intervals, the rise is H/n and angle is T/n degrees. Convert that angle to radians θ by multiplying by π/180.

At walkline radius r, the path length along the circle is rθ. The straight chord between the two endpoints is 2r sin(θ/2). For intervals that turn more than 180 degrees, the chord is also the chord of the complementary angle. A full-circle interval has a zero chord. The radial width between the edges is outer radius minus inner radius.

For each candidate count, check rise ≤ entered maximum and the selected arc or chord ≥ entered minimum. Equality is included. The rise check uses exact integers from the decimal input. Arc and chord thresholds use bounded computations for π and sine, with exact chord checks at 60 and 180 degrees and the full-turn zero case. A value whose bounds straddle the threshold remains marked at comparison precision. Plotted and displayed lengths are rounded.

Use one consistent length unit. Lengths support up to 1 million and up to six decimal places. The total turn is greater than zero through 720 degrees. The walkline is positive and can lie between the entered edge radii, including either valid endpoint. Candidate counts are whole numbers from 2 through 60. The worksheet compares equal-interval geometry against your stated dimensions. It leaves landings, tread shape, headroom, clearance, construction and regulatory acceptance to the project documents.

Worked Example

If you input:

  • Geometry: 2,800 mm rise, 360° turn, 100 mm inner radius and 1,000 mm outer radius
  • Walkline: 650 mm radius, measured as a straight chord
  • Limits: 190 mm maximum rise and 254 mm minimum walkline per interval
  • Candidates: 12 through 19

Result:

With the chord measure, only 15 intervals meet both limits. At 16 intervals the rise is 175 mm and the chord is 253.617419 mm. Switching to arc makes 16 pass because the arc is 255.254403 mm.

Frequently Asked Questions

What is the difference between the arc and chord?

The arc follows the circle at the selected radius. The chord is the straight segment joining its two endpoints. They use the same angle and radius.

Why can a larger interval count solve the rise and miss the run?

More intervals divide the same total vertical rise and turn. The rise decreases. For typical intervals within a half turn, the walkline distance also decreases.

Where should the walkline radius come from?

Enter the radius of the circular path you intend to check, according to your own plan or measurements. The workspace does not choose a location for you.

Why do the plan lines overlap for more than one turn?

The plan projects stations at different elevations on one horizontal plane. The repeated angular positions overlap in that view.

Does a passing count establish that the staircase is ready to build?

Passing means the modeled dimensions meet the two limits you entered. Headroom, landings, other dimensions and project requirements need separate checks.