Speaker Coverage & Listening Area Calculator
Enter two downward-facing footprint shapes at a reference drop from each speaker. Scale the circles to the listening plane and clip them to your measured area. Compare the covered, overlapping and uncovered areas with refinement bounds, then inspect a chosen listener position.
Compare speaker footprints and overlap
Scale two reference footprints and check the coverage area and a listener’s exact position.
Both footprints cover the probe.
Edit Speaker A footprint
Edit Speaker B footprint
Footprints clipped to the listening area
- Speaker A
- Speaker B
- Listener probe
- Speaker A modeled radius
- 2.8 m
- Speaker B modeled radius
- 2.8 m
Exact footprint and area bounds CSV
- At least one footprint · [2745/64, 3225/64] m²
- Both footprints · [45/64, 45/16] m²
- Uncovered area · [615/64, 1095/64] m²
How to use this calculator
- Enter the rectangle’s dimensions and the listening height.
- Enter each source’s location, height and circular footprint radius at a documented reference drop.
- Choose the grid density to refine the area bounds. Inspect the plotted union and overlap.
- Enter a listener point within the rectangle to check which footprints contain it.
- Download exact radii, probe membership and area intervals as CSV.
The Formula
The mathematical logic powering this calculation is:
Each source faces vertically down toward the same horizontal plane. For an entered reference footprint radius r₀ at reference drop d₀, the modeled radius at the listening plane is r = r₀ × (speaker height − listening height) / d₀. Coordinates use the same room origin for both sources and the listener probe. At one position, compare the exact squared horizontal distance from each source with its squared radius. Equality lies inside the footprint.
Divide the rectangle into an entered N by N grid. The nearest point in each cell to a source gives a lower squared distance bound, and the farthest corner gives an upper bound. When a full cell lies inside either footprint it contributes to a lower bound for coverage. A cell whose interior could meet either footprint contributes to the upper bound. Count cells inside both or possibly inside both to bound overlap. If the two closed circles are disjoint or only touch, their overlap area is zero. The uncovered bounds complement the covered bounds.
Distances, cell counts and area bounds use exact rational or integer arithmetic. Increasing the grid resolution refines these bounds. The SVG shows the circular model. The reference radius represents an entered listening-plane footprint. Published nominal polar angles and actual room sound levels use different measurement conditions. Room reflections, frequency-dependent directivity, phase, speech intelligibility and safe installation require separate assessment.
Enter room width and depth from 0.1 to 200 m. Use metre values to three decimals and place the probe in the listening rectangle. For each source, enter positive reference drop and radius, and a height above the listening plane.Worked Example
If you input:
- Listening rectangle: 10 × 6 m
- Listening height: 1.2 m
- Source centers: (2.6, 3) m and (7.4, 3) m
- Source height: 3.8 m each
- Reference: 2.8 m radius at 2.6 m drop
- Probe: (5, 3) m
Result:
The footprint radius is 2.8 m for each speaker. Both footprints cover the center probe and overlap inside the listening rectangle.
Frequently Asked Questions
What do the lower and upper area figures mean?
The true area in the entered geometry lies between them. Tiles fully covered count toward the lower figure, while any tile with possible interior coverage can count toward the upper figure.
Can two circles cover the same point without overlap area?
Yes. Two tangent circle boundaries can share an exact point with zero common area.
Why does the listening height matter?
It changes the vertical drop from each source. The radius scales in proportion to that drop under the circular model.
Does a published beam angle give the same footprint?
Use a listening-plane reference consistent with the coverage you want to model. A polar pattern measured at fixed distance differs from a section of the room at varying distance.
What happens when a speaker is outside the room outline?
Its circle can still intersect the listening rectangle. The area calculation counts only the part inside the rectangle.
Similar Calculators
Speaker Placement Calculator
Compare two listening seats in a rectangular room. Calculate stereo angle, direct timing mismatch, and first wall reflection paths.
Sound Transmission Loss & Partition Gap Calculator
Compare wall and door sound transmission with measured gap areas. See the power through each path and the allowable modeled gap by band.
Speaker Impedance & Amplifier Load Planner
Calculate speaker ohms for series and parallel layouts. Compare nominal loads with complex impedance at measured frequencies, phase and ideal RMS power.
Room Heat Loss & Retrofit Calculator
Explore room heat loss and sensible cooling, compare envelope and ventilation retrofits, and visualize heat flows and outdoor-temperature sensitivity with exact CSV ledgers.