Sound Transmission Loss & Partition Gap Calculator
Use band-specific sound transmission data to compare two doors or panels in the same partition. Enter the gross face and opening areas, then give each option a separate open area. Compare predicted direct airborne sound transmission with your targets from 125 Hz to 2 kHz. Investigate which path lets the most sound power through and how much equivalent open area each band can tolerate.
Compare wall, door and gap transmission
Trace the paths through one partition and check the sound transmission loss at each entered band target.
Only Option B meets every entered band target.
Composite loss by frequency band
- Option A
- Option B
- Band target
Review all band values
| Band | A (dB) | B (dB) | Target |
|---|---|---|---|
| 125 Hz | 27.6 | 30.87 | 27 dB |
| 250 Hz | 31.69 | 40.27 | 32 dB |
| 500 Hz | 35.69 | 43.63 | 37 dB |
| 1000 Hz | 36.96 | 46.99 | 40 dB |
| 2000 Hz | 38.09 | 47.73 | 43 dB |
125 Hz · Direct paths and gap budget
Option A
27.6 dB · Above target
Modeled gap budget 58.77 cm²
- Wall
- 15.76%
- Solid fill
- 76.58%
- Open gap
- 7.67%
Option B
30.87 dB · Above target
Modeled gap budget 179.27 cm²
- Wall
- 33.5%
- Solid fill
- 64.87%
- Open gap
- 1.63%
Shares describe how the transmitted power divides between the wall, solid fill and open gap at this band.
Full band and power CSV
How to use this calculator
- Measure the total partition face and the gross opening that holds either candidate.
- Enter the equivalent open area for each option inside that opening. Use zero when comparing fully sealed modeled options.
- Select each band to enter the wall loss, both solid-fill losses and your composite loss target.
- Inspect the bar chart to find the bands that miss target, then compare modeled path shares and the gap allowance for the selected band.
- Download the full band and power ledger as CSV.
The Formula
The mathematical logic powering this calculation is:
The total face area A includes the gross door or panel opening O. The opaque wall area is A − O. For one option, the effective clear gap g is contained inside O, leaving a solid opening fill of O − g. Convert square centimetres to square metres before comparing areas. Each loss in dB gives a transmitted power fraction τ = 10^(−loss/10). An ideal open gap has τ = 1.
At each band, transmitted fraction T = [(A − O) τ_wall + (O − g) τ_fill + g] / A. Composite loss = −10 log₁₀(T). The unnormalized terms in the numerator also give the fractions of transmitted power through the wall, solid fill and gap. This is an area-weighted power sum with equal incident intensity over the face.
For band target L, set T_limit = 10^(−L/10). Start from T_sealed, the comparison at g = 0. If it already exceeds the permitted transmitted fraction, the sealed option falls short. If the entire opening can be open and still meet the target, the budget is O. Otherwise solve g = A × (T_limit − T_sealed) / (1 − τ_fill). This is an approximate single-band comparison at fixed wall and opening areas. The calculation treats losses within 10⁻¹⁰ dB as equal for numeric comparisons. Modeled decimal values in the CSV retain up to twelve significant digits.
The model covers direct paths over one face under uniform incident intensity. Use comparable measured or laboratory band values that exclude any separate gap you enter. A material loss at one frequency and a single-number rating describe different quantities. Room absorption, flanking through other assemblies, sound leaks beyond the measured partition, receiver sound levels and installation certification require separate assessment.Worked Example
If you input:
- Partition: 15 m² face with a 2 m² opening
- Open gap: 20 cm² for Option A and 2 cm² for Option B
- Bands: 125, 250, 500, 1000 and 2000 Hz
- Target loss: 27, 32, 37, 40 and 43 dB
Result:
Option B meets all five targets. At 2000 Hz it gives about 47.73 dB modeled composite loss, and the modeled gap budget at the 43 dB target is about 6.99 cm².
Frequently Asked Questions
Why is the composite loss lower than the average of the parts?
The worksheet averages transmitted power fractions according to area. A weak path can transmit much more power per unit area than the surrounding wall, so averaging decibel values would hide its effect.
What happens if sealing the opening still misses a band target?
The gap budget is unavailable in that band. Under this model the wall or the sealed fill must improve before any gap allowance can be calculated.
How do I enter data for a door set measured with its seals?
Use comparable band-specific assembly data and count each transmission path once. Use zero for the separate gap input if the door test already contains the gap you want to model.
Can I enter STC or Rw for each component?
The worksheet takes band-specific transmission loss at the five labeled frequencies. STC and Rw summarize other measurements into single values and do not supply the required band inputs.
Why does a very small gap occasionally dominate transmitted power?
The model treats that open path as transmitting all incident power over its area. The solid paths transmit a much smaller share per unit area at their measured loss values.
Similar Calculators
Interior Door Installation Cost & Retrofit Fit Planner
Compare installed price and measured fit for an interior slab or prehung door. Check finished jamb or rough framing, prep offsets, and wall depth.
Speaker Placement Calculator
Compare two listening seats in a rectangular room. Calculate stereo angle, direct timing mismatch, and first wall reflection paths.
Wavelength & Phase Path Calculator
Calculate frequency and wavelength in up to four media. Compare path delay, wrapped phase and the shared frequency range for entered lengths.
Room Heat Loss & Retrofit Calculator
Explore room heat loss and sensible cooling, compare envelope and ventilation retrofits, and visualize heat flows and outdoor-temperature sensitivity with exact CSV ledgers.