Press Brake Force & Capacity Planner

Compare the force needed for a uniform air bend with the limits of the machine, punch, die and holder. Enter a tensile-strength range and compare up to twelve tool sets on a common scale. Inspect each capacity check, see how total force changes with bend length, and export the full calculation record. Metric and US units are built into one workspace with exact quantity-preserving conversions. This is an empirical force estimate using supplied nominal capacities, not a tooling recommendation, machine setting, geometry check or safety approval. A shorter bend can reduce total force while leaving an excessive line load unchanged.

Press brake force & capacity

Compare the force. Find the limiting component.

Explore material uncertainty and tooling loads before reviewing the setup with your machine and tooling documentation.

262.5 kN at upper strength. 3 nominal constraints exceeded.

Material, machine and tool-set inputs
Compare uniform, nominal air-bending loads. This is not a tool recommendation, machine setting or safety approval. Use documented material strength and manufacturer limits for the actual setup.

Changing units preserves quantities exactly. Fraction values may appear; enter decimals or a fraction such as 1/8. Correct invalid quantities before switching. US short ton-force differs from metric tonne-force.

Material and bend

Actual sheet thickness, not a gauge designation. Must be positive.

Length loaded uniformly during this bend; not the total perimeter of the part.

Use tensile strength, not yield strength. The two values describe your material uncertainty.

Must be at least the lower tensile strength; equal bounds give a single-strength scenario.

Machine limits

Enter the applicable documented force limit. No off-center or concentrated-load derating is calculated.

Documented usable length for this setup. A force check does not establish geometry suitability.

Compare tool sets

Supply independent punch, die and holder line-load limits. Shortening a bend reduces total force but does not reduce its line load.

Tool set 1

A descriptive name for chart, table and export labels; 1–100 characters.

Actual V opening, greater than material thickness. Force alone cannot determine flange or radius feasibility.

Manufacturer's applicable uniform load limit for the punch.

Manufacturer's applicable uniform load limit for the die.

Manufacturer's applicable uniform load limit for the holder.

Tool set 2

A descriptive name for chart, table and export labels; 1–100 characters.

Actual V opening, greater than material thickness. Force alone cannot determine flange or radius feasibility.

Manufacturer's applicable uniform load limit for the punch.

Manufacturer's applicable uniform load limit for the die.

Manufacturer's applicable uniform load limit for the holder.

Tool set 3

A descriptive name for chart, table and export labels; 1–100 characters.

Actual V opening, greater than material thickness. Force alone cannot determine flange or radius feasibility.

Manufacturer's applicable uniform load limit for the punch.

Manufacturer's applicable uniform load limit for the die.

Manufacturer's applicable uniform load limit for the holder.

Estimated total force
262.5 kN
700 MPa tensile strength
Uniform line load
262.5 kN/m
Unchanged when only bend length changes
Nominal constraints exceeded
3 of 5
Punch line load, Die line load, Holder line load
Nominal length bound
No positive length
A tool or holder line-load limit is exceeded. A shorter bend cannot fix this.

Force equivalents: 26.77 metric tonne-force; 29.51 US short ton-force. V/thickness = 8. These force calculations do not validate flange length, bend radius, tool geometry or cracking risk.

Compare all tool sets

Solid blue: lower-strength force. Outlined purple: upper-strength force. Dashed marker: the smallest entered machine or tooling force capacity at this bend length. Common scale: 0–262.5 kN.

16 mm opening

Lower: 157.5 kN · Upper: 262.5 kN · Nominal capacity: 160 kN

20 mm opening

Lower: 117.6 kN · Upper: 196 kN · Nominal capacity: 160 kN

24 mm opening

Lower: 93.33 kN · Upper: 155.56 kN · Nominal capacity: 160 kN

A wider V opening lowers calculated force, but that alone is not a tooling recommendation. Capacity shown here excludes the usable-length check.

Which limit is controlling?

100% reaches the entered nominal limit. Values above 100% are shown without clipping. Negative headroom means demand exceeds the limit.

Machine force87.5% — Within nominal limit

Punch line load131.25% — Exceeded

Die line load164.06% — Exceeded

Holder line load145.83% — Exceeded

Usable length50% — Within nominal limit

Selected tool set at upper strength
ConstraintDemandLimitHeadroomUtilizationStatus
Machine force262.5 kN300 kN37.5 kN87.5%Within nominal limit
Punch line load262.5 kN/m200 kN/m−62.5 kN/m131.25%Exceeded
Die line load262.5 kN/m160 kN/m−102.5 kN/m164.06%Exceeded
Holder line load262.5 kN/m180 kN/m−82.5 kN/m145.83%Exceeded
Usable length1,000 mm2,000 mm1,000 mm50%Within nominal limit

How force changes with bend length

Horizontal axis: 0–2,000 mm. Vertical axis: 0–525 kN. Solid blue: lower strength; dashed purple: upper strength. Dotted black: machine force. Thin gray: current bend length.

Force versus bend length for the selected tool setBoth strength scenarios increase linearly with bend length. Machine force is 300 kN. Current length is 1,000 mm. Numerical endpoints and line-load constraints are provided below.
  • Lower strength: 315 kN at 2,000 mm. Nominal length bound: 1,904.76 mm.
  • Upper strength: 525 kN at 2,000 mm. No positive length meets every line-load constraint.

This chart shows machine-force demand, not a complete operating envelope. Tool and holder line loads stay constant as length changes; the usable bed length also applies.

Calculation record

Export exact canonical quantities, all entered limits, both strength scenarios and every tool set. Fractions preserve calculation precision. Display rounding is not a statement of empirical accuracy.

How to use this calculator

  1. Load the 1 m bend example, then open Material, machine and tool-set inputs. Choose metric or US units; conversion preserves existing quantities.
  2. Enter actual material thickness, uniformly loaded bend length and a documented tensile-strength range. Use tensile strength, not yield strength or a gauge number.
  3. Enter the applicable machine force and usable bending length. Add candidate tool sets with their actual V openings and independent punch, die and holder uniform line-load limits.
  4. Inspect each tool set at both strength endpoints. Read the five individual checks and their headroom rather than relying on total tonnage alone. Try the 100 mm example to see why line-load overload persists on a shorter bend.
  5. Review the force-versus-length chart and nominal length bound, then download the CSV or show its selectable text. Confirm the actual setup against manufacturer documentation; the calculation does not approve operation.

The Formula

The mathematical logic powering this calculation is:

For uniform air bending, line load q = Rm × t² / V × (1 + 4t/V), with tensile strength Rm in MPa and thickness t and die opening V in mm. q is in kN/m. Total force F = q × L / 1000 for bend length L in mm. Evaluate both supplied tensile-strength endpoints independently. This implements the geometry-dependent factor shown in Bystronic's RF-A bending-tools formula; it does not substitute a universal 1.42 factor.
Compare F with the entered machine force limit. Compare q separately with the punch, die and holder line-load limits; compare L with usable bending length. Utilization = demand / limit × 100%. Headroom = limit − demand. Equality reaches the nominal limit and is not classified as exceeded. This is not a safety margin or operating approval. Equivalent total capacity at the current length is the minimum of machine force and each line-load limit × L/1000.
If any tool or holder line-load limit is exceeded, no positive nominal length can resolve that constraint. Otherwise the nominal length bound is min(1000 × machine force / q, usable length). All tied limiting constraints are retained. The length chart shows force demand and machine force only, not a complete operating envelope.
1 inch = 25.4 mm; 1 metric tonne-force = 9.80665 kN; 1 US short ton-force = 8.896443230521 kN. US line loads use short ton-force per foot. Exact fractions preserve quantities during conversion and export; display values are rounded to two decimal places except meaningful tiny nonzero values. Broad numerical input bounds are computational limits, not validation of the empirical formula for every material or geometry. Bottoming, coining, hemming, off-center or concentrated loads, tooling geometry, flange feasibility, springback and cracking are outside scope.

Worked Example

If you input:

  • Material: 2 mm thickness; 420–700 MPa tensile strength
  • Bend: 1,000 mm uniformly loaded length
  • Machine: 300 kN nominal force; 2,000 mm usable length
  • Tool sets: 16, 20 and 24 mm V openings
  • Uniform line-load limits: Punch 200 kN/m; die 160 kN/m; holder 180 kN/m

Result:

For V = 16 mm, q = Rm × 4/16 × (1 + 8/16). At 420 MPa this is 157.5 kN/m; at 700 MPa it is 262.5 kN/m. For a 1 m bend the total forces are 157.5 and 262.5 kN. The upper case is below the 300 kN machine limit but exceeds all three tooling line-load limits. At V = 20 mm, upper line load is 196 kN/m, exceeding die and holder limits. At V = 24 mm, upper line load is 1400/9 kN/m (155.56 displayed), within all entered nominal limits. Its upper-strength nominal length bound is 13500/7 mm (1,928.57 displayed), limited by machine force. Shortening the V = 16 mm bend to 100 mm lowers upper total force to 26.25 kN but leaves line load at 262.5 kN/m and all three tooling overloads unchanged. These illustrative limits are not manufacturer ratings for a specified real tool.

Frequently Asked Questions

Is press brake tonnage the same as tooling capacity?

No. The machine has a force limit while punches, dies and holders also have applicable line-load limits. This planner checks each separately and checks usable bending length. A total force below machine capacity can still overload a tool or holder.

Why does a shorter bend still exceed a line-load limit?

The empirical line load depends on tensile strength, thickness and V opening, not bend length. Shortening the bend reduces force and the uniformly loaded tool's equivalent total capacity together; their utilization ratio remains unchanged.

Can the planner select a safe V die for me?

No. Increasing the V opening reduces calculated force but also changes bending geometry. Minimum flange, bend radius, punch geometry, material behavior and the actual machine/tool configuration require separate evaluation.

Does the formula cover bottoming or coining?

No. The method is for uniform air bending. Do not apply its results to bottoming, coining or hemming, or assume it includes off-center and concentrated-load derating.

Are the lower and upper strengths confidence intervals?

No. They are supplied tensile-strength endpoints. Equal endpoints represent a single material strength. The calculator does not infer a statistical distribution, material certificate or probability of exceeding a limit.

Which ton does the US display use?

US force values use US short ton-force, not metric tonne-force or long ton-force. The results show both metric tonne-force and US short ton-force equivalents. US line loads are short ton-force per foot.

What does the nominal length bound mean?

If every tooling line-load check is satisfied, it is the smaller of the machine-force length limit and usable bed length. Otherwise no positive length satisfies every entered constraint. It is not an approved maximum operating length or an assessment of tool geometry.

Why do fractions appear when I change units?

Exact fractions avoid silently changing physical quantities during conversion. You can retain them or enter a revised decimal quantity. Blank or invalid quantities remain editable and prevent dependent results and exports.

Similar Calculators