Pool Stabilizer (CYA) Mix & Label Worksheet

Use supplied pool volume, current CYA, fill-water CYA and an explicitly authored target to compare two independent fixed-volume replacement scenarios. Trace retained, removed and fill-water CYA mass, plot the dilution line and see whether the target is arithmetically reachable under your fraction and product-mass bounds. An optional label worksheet compares the entered CYA mass fraction with a separately entered stated rise. Rounded label statements are never treated as an assay or averaged into one result. This worksheet does not select a safe CYA target, evaluate sanitation, give chemical-handling steps or authorize a structural water replacement.

Measured readings · exact ledger · authored bounds

Separate dilution math from label assumptions

Compare two ideal mixtures, retain fill-water CYA, and distinguish a composition declaration from a stated label rise.

Compare the two entered mixtures

A mixed 62.5 mg/L; B mixed 38 mg/L

Scenario A · 25% replacement

Before authored product

62.5 mg/L

-17.5 mg/L from the current reading · 9463.5295 L represented by the fraction

Scenario B · 60% replacement

Before authored product

38 mg/L

-42 mg/L from the current reading · 22712.471 L represented by the fraction

The target and bounds are your arithmetic assumptions. This worksheet gives no safe CYA target, sanitation verdict, chemical-handling steps or structural water-replacement advice. Displayed ppm readings use the dilute-water mg/L convention.

Use supplied readings and an authored target

Examples are illustrative, including the target and replacement bound. Use actual test readings and a known water volume. A blank, unknown or off-scale CYA result is not zero.

Enter values in the selected units. Changing a unit selector reinterprets its number; it does not convert the typed measurement.

The original and fill samples are separate measurements; no zero-fill assumption.

Your chosen numerical reference, not a safe target or operating recommendation.

0–100%. This is a mathematical bound, with no assessment or permission to remove pool water.

Product interpretation
Scenario A
Scenario B

Homogeneous, fixed-volume arithmetic only. No sequential replacement, simultaneous flow-through, density correction, reaction, dissolution timing or test-accuracy guarantee is modeled.

Ideal replacement line

Each point independently mixes original water at 80 mg/L with fill water at 10 mg/L, keeping 37854.118 L final volume. Product interpretations are excluded from this line.

88 mg/L at top0 mg/L at bottom
CYA concentration versus ideal replacement fractionAt zero replacement the concentration is 80 mg/L; at the 75% bound it is 27.5 mg/L. A is 62.5 and B is 38 mg/L. Dashed amber is your target, not a safe operating threshold.
0% replacement75% authored bound

Teal circle = A; blue square = B. Overlapping markers can share a point. The axis represents one ideal mixture, not elapsed time or repeated replacements.

64.285714% is the algebraic target crossing; inside the entered 0–75% bound

Reachability under your entered bounds

Allow 0–75% ideal replacement. These are mathematical corner bounds, with no selected action or recommended operating range.

Dilution only

27.5 – 80 mg/L

Authored target 35 mg/L is inside this arithmetic envelope.

Conserved CYA ledger

Initial modeled CYA mass is 3028.3294 g. Removed + retained equals that initial mass; retained + fill equals the mixed-water mass. Nominal label equivalents are listed separately in the CSV.

Show exact-source mass ledger
Each scenario starts from the same original measured water. Display values are rounded; CSV includes exact fractions.
Mass-balance componentABUnit
Represented replacement water9463.529522712.471L
CYA removed with original water757.082361816.9977g
CYA retained from original water2271.24711211.3318g
CYA carried by fill water94.635295227.12471g
CYA in mixed water2365.88241438.4565g
Mixed concentration62.538mg/L

Keep the measured assumptions and math

The live local CSV records normalized inputs, exact mass fractions, separate interpretations, bounds, crossing and dilution-curve points.

Show selectable CSV

How to use this calculator

  1. Enter an actual water volume, current CYA test result, fill-water CYA result and the target you intend to compare. The example target is illustrative and is not a recommendation.
  2. Set your arithmetic replacement bound and two independent scenario fractions. The model assumes uniform mixing and the same final volume; it gives no structural or draining procedure.
  3. Keep Dilution only, or enable an interpretation supported by the label you actually have. Enter an explicit CYA mass percentage or a stated label mass/water/rise tuple. Available chlorine is a different quantity.
  4. If product interpretation is enabled, enter the authored product bound and scenario masses. Read each interpretation separately; nominal label scaling is not a measured outcome and is not averaged with the mass balance.
  5. Inspect the dilution plot, target crossing, arithmetic envelopes and exact mass ledger. Export the worksheet without treating a reachable number as a sanitation verdict or a direction to change the pool.

The Formula

The mathematical logic powering this calculation is:

Treat displayed dilute-water ppm readings as mg/L within this worksheet. For fixed water volume V litres, current measured CYA C, fill measurement F and an ideal replacement fraction r, mixed concentration is C(1−r)+Fr. Initial CYA grams = VC/1000. Removed grams = VCr/1000; retained grams = VC(1−r)/1000; fill-water CYA grams = VFr/1000. Retained plus fill equals mixed mass. The final volume remains V. Each scenario independently starts with the original measured water. No sequence of partial replacements, simultaneous flow-through, evaporation, reaction, dissolution rate, precipitation or unmeasured CYA source is inferred.
If C differs from F, the dilution-only algebraic target fraction is r=(target−C)/(F−C). The model retains signed roots and checks them against the entered 0-to-maximum replacement bound. An outside root is not clipped into a feasible fraction. If C=F, every fraction matches an equal target and no fraction reaches a different target. A computed fraction is an arithmetic crossing, not advice to drain or permission to remove water.
Optional CYA mass-fraction interpretation: an entered product mass m grams with declared CYA fraction p contains mp grams of CYA, and the ideal concentration increase is 1000mp/V mg/L. The declared percentage is divided by 100 to obtain p. Only an explicit CYA mass percentage belongs here; available-chlorine percentage, liquid volume, density guesses and other pool products are not substituted.
Optional stated-label-rise interpretation: if an entered label says mass M grams for water W litres corresponds to rise D mg/L, nominal scaled rise for authored mass m in V is D(m/M)(W/V). Its CYA-equivalent mass is rise×V/1000. That equivalent is an algebraic label scale, not a chemical assay, measured outcome or proof of physical purity. The rate-equivalent percentage is 100DW/(1000M); even a value above 100% is retained as an inconsistency diagnostic rather than silently accepted as actual composition. Both interpretations stay separate when compared.
The manufacturer Poolife label shown in the cited assets declares 98.5% CYA and separately states 1 lb per 10,000 US gallons for a 10 ppm rise. Exact mass-fraction arithmetic for that same authored dose gives about 11.802903 mg/L, while nominal label scaling gives 10. This factual label example does not reconcile the difference or override the product's full directions. No handling or addition procedure is supplied here.
For each selected interpretation, the arithmetic envelope allows replacement r anywhere from 0 to the authored maximum and product mass m anywhere from 0 to its authored nonnegative bound. The minimum is min(C, C+(F−C)rmax); the maximum is max(C,C+(F−C)rmax) plus that interpretation's rise at the product bound. The affine image fills the interval, so inclusive membership establishes mathematical reachability. The envelope is not an operating range, statistical confidence interval, dosing recommendation or assurance of a safe pool. No optimal physical action is selected.
Water inputs normalize to litres:1 US liquid gallon = 3.785411784 L; product and label mass normalize to grams:1 avoirdupois pound = 453.59237 g. Imperial gallons, fluid ounces, liquid-product volume and assumed density are unsupported. Exact decimal rational arithmetic preserves ledgers, crossings, bounds and exported fractions before display rounding. Measurements and product statements themselves remain user assumptions.
Plain unsigned decimal inputs allow six places. Current, fill and target readings 0–10,000 mg/L; replacement fractions 0–100%; normalized water and label volumes positive through 1,000,000,000 L; product bounds 0–1,000,000 g; declared CYA percentage positive through 100%; label mass and rise positive. Chosen fractions and masses must be inside the authored bounds. These are software limits, not safe concentrations or product/application guidance. Inactive mode drafts are retained and ignored.

Worked Example

If you input:

  • Water volume: 10,000 US liquid gallons
  • Measured current / fill CYA: 80 / 10 mg/L
  • Authored target: 35 mg/L, illustrative only
  • Comparison bound: 0–75% ideal replacement
  • Scenarios: A 25%, B 60%; dilution only

Result:

A mixes to 62.5 mg/L and B to 38 mg/L. The algebraic 35 mg/L crossing is 450/7%= 64.285714…%, inside the authored0–75% bound. The bounded dilution envelope is 27.5–80 mg/L. Fill water contributes CYA, so replacing 60% does not produce the 32 mg/L result that a zero-fill assumption would give. These are ideal arithmetic comparisons, not a recommended target or permission to replace water.

Frequently Asked Questions

Does a reachable CYA target mean the pool is safe?

No. Reachable describes this affine model and the bounds you entered. CDC treats chlorine, pH and water testing as separate pool-health requirements and notes that CYA affects disinfection. This worksheet supplies no sanitation verdict, safe target or contamination-response guidance.

Why do I need a fill-water CYA result?

The replacement water contributes its own concentration. A nonzero fill reading changes the entire dilution line and can put a target outside the allowed envelope. A blank, unknown or off-scale reading is not silently treated as zero.

Is the fraction a drain instruction?

No. It is a mathematical fixed-volume mixture fraction, with no assessment of groundwater, pool structure, equipment, local restrictions or feasibility. The worksheet gives no procedure or authorization to remove pool water.

Why can the label rise differ from CYA mass percentage?

A composition declaration and a rounded nominal dose statement are different inputs. The cited Poolife label supplies both 98.5% CYA and 1 lb for a 10 ppm rise in 10,000 US gallons; exact composition arithmetic and that nominal scaling differ. The worksheet keeps their results distinct and does not reinterpret the rate as purity.

Can I use the available-chlorine percentage or liquid ounces?

No. The mass-fraction field requires an explicit CYA mass percentage. Available chlorine, dichlor/trichlor content and liquid-product volume are different quantities. This worksheet does not infer CYA from them or invent a density.

What if fill water has more CYA than the current reading?

The same balance slopes upward. Replacement can raise the modeled concentration rather than dilute it. The algebraic crossing and attainable interval use the signed difference and do not force a decreasing curve.

What happens when current and fill measurements are equal?

Replacement leaves the modeled concentration unchanged. An equal target is matched at every allowed fraction; a different target has no dilution-only crossing. Optional authored product interpretations remain separate.

Do repeated replacements or immediate testing follow this line?

No. The plotted line represents independent single-step fixed-volume mixtures of the original well-mixed water and the stated fill water. It does not simulate sequential replacements, flow-through, dissolution or test kinetics, and it cannot establish that an actual measurement is complete or accurate.

Similar Calculators