Check the annular space around a round pipe and compare two vendor-provided dimensional envelopes. Enter the actual pipe outside diameter, sleeve inside diameter, allowed diameter variations, and horizontal and vertical center shift. Inspect the nominal section and the tolerance cases that make the gap narrowest or widest.
Check the gap around a pipe penetration
Compare two vendor-provided dimensional limits against a measured pipe, sleeve and center shift.
Edit measured dimensions and tolerances
Edit both seal options
Use the documented gap and offset limits for each complete option. Enter zero offset for a centered-only seal.
Compare the measured and tolerance sections
- Near gap
- 0.7 in
- Far gap
- 1.3 in
- Center offset
- 0.3 in
Blue ring · sleeve. Teal disk · carrier pipe.
Option checks use the full tolerance range for every cross-section view.
Option A
Meets all entered limits
On limit
- Tolerance case
- 0.32 in
- Maximum allowed
- 0.32 in
Option B
Outside one or more limits
Within limit
- Tolerance case
- 0.32 in
- Maximum allowed
- 0.4 in
Review dimensional checks and export
| Option and check | Modeled | Limit | Result |
|---|---|---|---|
| A · Narrowest gap | 0.66 in | 0.65 in | Within limit |
| A · Widest gap | 1.34 in | 1.36 in | Within limit |
| A · Maximum center offset | 0.32 in | 0.32 in | On limit |
| B · Narrowest gap | 0.66 in | 0.7 in | Outside limit |
| B · Widest gap | 1.34 in | 1.36 in | Within limit |
| B · Maximum center offset | 0.32 in | 0.4 in | Within limit |
How to use this calculator
- Enter the actual sleeve bore and carrier pipe diameters at the planned sealing plane. Include their dimensional tolerances.
- Enter the two signed center shifts and any additional radial uncertainty. Treat positive horizontal as right and positive vertical as up.
- Copy the gap band and offset limit for each option from the vendor's written dimensions.
- Compare the measured, narrow-gap and wide-gap cases in the cross-section. Select a check to see which option is at or outside its limits.
- Open the verification ledger to inspect each comparison or download the exact operands.
The Formula
The mathematical logic powering this calculation is:
Model one cross-section with a circular opening and a circular carrier pipe on a common plane. Use the actual sleeve inside diameter S and pipe outside diameter P, with their independent symmetric diameter tolerances. At the same center the gap is (S − P) / 2. The smallest centered gap uses the smallest sleeve and largest pipe. The largest centered gap uses the largest sleeve and smallest pipe.
For entered signed horizontal and vertical shift x and y, the nominal eccentricity is √(x² + y²). The separate radial offset allowance is the maximum extra movement in any direction. The largest possible eccentricity is the nominal eccentricity plus the allowance, since both can align. Subtract that largest eccentricity from the smallest centered gap to get the narrowest gap. Add it to the largest centered gap to get the widest gap. A negative narrowest gap means projected interference and zero means contact.
Compare both extreme gaps with the vendor's closed dimensional band, and compare the largest eccentricity with the vendor's separately stated offset cap. All three checks must pass. To decide a boundary exactly, isolate the nominal square root. A negative remaining budget fails, otherwise square the budget and compare directly with x² + y². Equality passes and is marked on limit. The CSV contains these exact squared operands as well as human-readable modeled values. Inputs use up to three decimals in inches.
Use a vendor-confirmed envelope that covers the exact assembly. A centered-only option has a zero offset cap. The worksheet checks the entered dimensions at one cross-section. Product selection, sealing pressure, fire rating, fastening, supports, axial movement, tilted or misshapen penetrations and installation verification require the specified product details.Worked Example
If you input:
- Sleeve and pipe: 8 in sleeve bore, 6 in pipe OD, both with ±0.020 in diameter tolerance
- Offset: 0.180 in right, 0.240 in up, plus 0.020 in radial allowance
- Option A: 0.65–1.36 in gap, maximum 0.320 in offset
- Option B: 0.70–1.36 in gap, maximum 0.400 in offset
Result:
The tolerance gap is 0.66–1.34 in. Only Option A meets all limits, exactly at its 0.320 in maximum center offset. Increasing horizontal shift by 0.001 in pushes A beyond that cap, while B still requires a wider minimum gap.
Frequently Asked Questions
Why use the inside sleeve and outside pipe dimensions?
They are the two boundaries that delimit the free annular gap. Nominal pipe and sleeve sizes can differ from the dimensions at those boundaries.
Why is the gap different at opposite points?
Moving a circular pipe off center shortens the gap in the direction of shift and widens it opposite that direction by the same distance.
How should I enter a seal that requires a centered pipe?
Use zero for its maximum allowable center offset. Any entered center shift or radial allowance then falls outside that limit.
Are the narrowest and widest gaps from the same pipe and sleeve dimensions?
Each is a separate tolerance corner. The narrow corner uses the smallest sleeve and largest pipe, and the wide corner uses the largest sleeve and smallest pipe.
Can I use this to pick a brand-specific link count?
Use the manufacturer's product selection guide for link count and assembly options. Here you can compare the already supplied geometric limits with your measured opening and pipe.
Similar Calculators
O-Ring Squeeze & Gland Fill Calculator
Compare two static O-ring cavity tolerance ranges. Check minimum and maximum squeeze, gland fill, and dimensional bounds using your entered targets.
House Repipe Route, Stock & Quote Planner
Compare house repiping costs by mapping fixture runs, calculating whole PEX coils and checking which labor and restoration charges each quote includes.
Pipe Weight Calculator & Contents Planner
Compare empty, partly filled and full pipe weights from measured outside diameter and wall thickness, listed dry mass and separate fittings.