O-Ring Squeeze & Gland Fill Calculator

Enter the installed circular ring cross-section limits and the closed cavity dimensions for two rectangular static face glands. Compare their full squeeze and cross-sectional fill ranges, see which dimensional limits hold at every tolerance extreme and audit the input combinations.

Static face gland

Compare O-ring squeeze and gland fill

Ring dimensions and target limits

Enter the circular cross-section diameter in its installed radial position, before axial squeeze.

Gland A
Gland B
Only Gland A meets both limits across its full range.
Gland A
Full range within limits
Squeeze and fill meet the entered limits
Squeeze 15–25%
Entire range within limit
Fill 64.465–83.7758%
Entire range within limit
Minimum cavity width at smallest height
3.9424 mm for the entered fill cap
Gland B
Review dimensional limits
See squeeze and fill separately below
Squeeze 11.6667–26.5625%
Part of range outside limit
Fill 66.6847–95.0647%
Part of range outside limit
Minimum cavity width at smallest height
4.0263 mm for the entered fill cap

Compare the tolerance envelopes

Axial squeeze (%)Shaded region is the entered target
AB102030
  • Gland A
  • Gland B

Height that meets the squeeze target across all ring sizes2.4–2.55 mm

Review tolerance corners and export CSV
Dimension combinations at the entered bounds
GlandRing (mm)Height (mm)Width (mm)Squeeze (%)Fill (%)
Gland A · 132.442073.6311
Gland A · 232.44.32068.494
Gland A · 332.5541569.2998
Gland A · 432.554.31564.465
Gland A · 53.22.442583.7758
Gland A · 63.22.44.32577.931
Gland A · 73.22.55420.312578.8478
Gland A · 83.22.554.320.312573.3468
Gland B · 132.353.621.666783.553
Gland B · 232.35421.666775.1977
Gland B · 332.653.611.666774.0942
Gland B · 432.65411.666766.6847
Gland B · 53.22.353.626.562595.0647
Gland B · 63.22.35426.562585.5583
Gland B · 73.22.653.617.187584.3027
Gland B · 83.22.65417.187575.8724

How to use this calculator

  1. Enter the minimum and maximum installed ring cross-section diameter before axial squeeze.
  2. Enter the minimum and maximum squeeze targets and the maximum fill figure from your requirements.
  3. Enter the closed height and cavity width bounds for both face glands.
  4. Toggle between squeeze and fill envelopes. Compare the calculated height window and the minimum width at each smallest height.
  5. Open the tolerance corners and export the worksheet. Squeeze values and the factors of π are retained as exact fractions.

The Formula

The mathematical logic powering this calculation is:

Use one solid circular cross-section ring and an ideal rectangular static face cavity per option. Let D be ring cross-section diameter in its installed radial position before the faces squeeze it, H the closed height and W the width of the modeled rectangle. Squeeze is 100 × (D − H) ÷ D. Negative squeeze means the entered section is smaller than the closed height. Cross-sectional fill is 100 × (πD²/4) ÷ (HW). This is the local cross-sectional model with square corners and no extra void or stretch calculation.
Minimum squeeze uses the smallest ring and largest height. Maximum squeeze uses the largest ring and smallest height. Minimum fill uses the smallest ring and largest height and width. Maximum fill uses the largest ring and smallest height and width. All dimensional bounds are treated as independently attainable. The audit lists the distinct combinations of endpoints. Squeeze compares exactly to a closed entered band, including equality. Fill compares the exact factor of π with a 38-decimal bracket before applying the cap.
A closed height meeting the squeeze band for all entered ring diameters must lie between Dmax × (1 − upper squeeze/100) and Dmin × (1 − lower squeeze/100). A reversed range or a nonpositive upper bound leaves no positive height. The minimum cavity width for the entered fill cap uses the largest ring and smallest entered height. It equals 25πDmax² ÷ (Hmin × fill cap), with the cap entered as a percentage. Zero cap has no finite width when the ring area is positive.
Ring bounds accept 0.1–30 mm and cavity bounds 0.1–100 mm. Squeeze targets and fill cap accept 0–100%, with at most six decimal places. The example dimensions and limits are illustrative. This worksheet checks only the entered geometric model. Material selection, corner radii, extrusion clearance, contact force, assembly effects, pressure, temperature, chemical swelling, dynamic seals and service suitability are outside the model.

Worked Example

If you input:

  • Ring cross-section: 3.0–3.2 mm
  • Squeeze targets: 15–25%
  • Maximum gland fill: 85%
  • Gland A: Closed height 2.40–2.55 mm, width 4.0–4.3 mm
  • Gland B: Closed height 2.35–2.65 mm, width 3.6–4.0 mm

Result:

Gland A exactly reaches the squeeze limits of 15% and 25%, with maximum fill about 83.7758%. Gland B spans about 11.6667–26.5625% squeeze and reaches about 95.0647% fill. Only A meets both entered limits across its full range.

Frequently Asked Questions

Is the ring cross-section the same as its outside diameter?

The cross-section is the diameter of the circular material form. Enter its installed value before axial closure. The full ring outside diameter includes the central opening and is a different measurement.

Can changing width change the squeeze?

Squeeze in this model depends only on ring cross-section and closed height. Width changes the rectangular cavity area and therefore the modeled gland fill.

What does a negative squeeze value mean?

The closed height is greater than the ring cross-section diameter at that combination, leaving geometric clearance in the squeeze direction.

Why is the width check calculated at the smallest closed height?

For the same ring and width, a smaller cavity height creates a smaller cross-sectional area. Using the largest ring and smallest height gives the width required to keep the whole dimensional range at or below the cap.

Why can no closed height satisfy the entered squeeze band?

The largest ring can require a height greater than what the smallest ring allows to stay above the minimum squeeze. When those bounds cross, there is no common height meeting both limits for the whole ring range.

Which squeeze and fill limits should I enter?

Enter the documented requirements for your actual seal application. This worksheet compares supplied dimensions and limits, while the examples are illustrative.

Similar Calculators