Hydraulic Cylinder Force & Cycle Calculator
Enter bore, rod and stroke plus your chamber pressures, resistance and flow caps. See which flow cap limits each stroke and the pressure required for each entered load.
Compare hydraulic cylinder force
Compare push and pull across two geometries, account for opposing pressure, and find the flow cap that controls cycle time.
Geometry and chamber inputs
Force and cycle envelope
- Solid A
- Dashed B
- ● Entered drive
- □ At entered load
The force trace holds return pressure at 16 bar. The horizontal line marks the 30 kN entered load.
Plan A · Push
Above entered load33.898 kN
- Load margin
- 3.898 kN
- Required drive
- 107.496 bar
- Flow-only stroke
- 2.672 s
Supply flow caps speed
Plan B · Push
Above entered load54.671 kN
- Load margin
- 24.671 kN
- Required drive
- 70.919 bar
- Flow-only stroke
- 4.308 s
Supply flow caps speed
Chamber and flow ledger
Plan A
Cap 3117.245 mm² · annular 2099.369 mm²
Push
Inlet / exhaust 28 / 18.857 L/min
Inlet / exhaust volume 1.247 / 0.84 L
Flow-only speed 149.705 mm/s
Pull
Inlet / exhaust 16.163 / 24 L/min
Inlet / exhaust volume 0.84 / 1.247 L
Flow-only speed 128.318 mm/s
Plan B
Cap 5026.548 mm² · annular 3436.117 mm²
Push
Inlet / exhaust 28 / 19.141 L/min
Inlet / exhaust volume 2.011 / 1.374 L
Flow-only speed 92.84 mm/s
Pull
Inlet / exhaust 16.406 / 24 L/min
Inlet / exhaust volume 1.374 / 2.011 L
Flow-only speed 79.577 mm/s
How to use this calculator
- Enter the measured bore, rod diameter and stroke for each single-rod cylinder.
- Enter driving and opposing gauge pressures at the chambers. Use supply and exhaust flow caps available at the cylinder for the same comparison.
- Enter the axial loads and the resisting force you want to include. Compare push and pull traces and their required pressures.
- Open cycle time to inspect flow-only travel. Review individual chamber volumes, flow caps and force margins in the CSV.
The Formula
The mathematical logic powering this calculation is:
For bore D and rod d in millimetres, cap area is πD²/4 and rod-side annular area is π(D² − d²)/4. Pushing drives the cap area, and pulling drives the annular area. The opposite chamber supplies back pressure against the direction of the stroke.
For driving area A and opposing area B, signed force in kN is (drive_bar × A − return_bar × B)/10,000 minus the entered axial resistance. Load margin subtracts the direction's entered load. Required driving pressure in bar is [10,000 × (load + resistance) + return_bar × B]/A.
The same speed displaces different volumes on the two sides. With flows entered in L/min, flow-only velocity in mm/s is 10⁶/60 times the smaller of supply/A and exhaust/B. A positive speed gives stroke time = stroke/speed. A full cycle sums both strokes with no dwell. When a flow cap is zero, there is no positive modeled speed or finite stroke time. Oil volume for either chamber is its area times stroke divided by 10⁶ in litres.
The flow limit compares exact rational area/flow ratios before π cancels. The load relation uses rational lower and upper bounds for π. Rounded numerical values support charts and export. Enter positive bore and rod diameters up to 1,000 mm with rod smaller than bore, stroke up to 20,000 mm, gauge pressures from 0 to 1,000 bar, flow caps from 0 to 10,000 L/min and load or resistance up to 1,000,000 kN. Use decimal values with up to six places or fractional values with a positive denominator of up to six digits. The worksheet covers an ideal axial pressure balance and flow envelope. Mountings, buckling, pressure ratings, compliance, transients and verified load capacity require their own inputs or analysis.Worked Example
If you input:
- Plan A: 63 mm bore, 36 mm rod, 400 mm stroke
- Plan B: 80 mm bore, 45 mm rod, 400 mm stroke
- Drive and return: 120 and 16 bar
- Supply and exhaust: 28 and 24 L/min
Result:
Plan A has 33.898 kN of push and 20.055 kN of pull. Supply caps the push speed and exhaust caps the pull speed. Plan B has 54.671 kN of push and takes 9.335 seconds per flow-only cycle.
Frequently Asked Questions
Why are push and pull forces different?
The rod occupies some of the piston face on the rod side. That reduces the driving area on a pull stroke, and the full cap area then sees opposing pressure.
How can exhaust limit a stroke when supply flow is available?
The displaced oil must have an exit path. The opposing area times piston speed sets the exhaust requirement, which may exceed the entered exhaust cap first.
What does negative net force mean?
With these entered pressures and resistance, the modeled force in the commanded direction is negative. The opposing contribution dominates before the entered external load.
Does the plotted cycle time assume the load moves?
The time describes motion implied by incompressible flow, chamber geometry and stroke. The load headroom is evaluated separately, and actual motion also depends on the system.
Which pressures belong in the fields?
Use the gauge pressure at the driving chamber and the opposing gauge pressure at the other chamber. The shared scenario uses those two values for both commands, with the areas reversed.
Where do acceleration and end cushions appear?
The model uses constant flow during a full stroke and no dwell. Changes in flow, acceleration, valve timing and cushions need a time-dependent model.
Similar Calculators
Valve Cv Calculator & Catalog Travel Window
Compare entered valve Cv curves under clean-liquid assumptions. See where catalog travel may meet a flow target at an entered pressure drop range.
Pump Curve & Operating Point Planner
Compare pump curves and speeds against system head. Visualize operating flow, runtime, electrical energy and whether your target volume fits the available hours.
Measured Pump Head Calculator & Tap Audit
Calculate pump head from recorded suction and discharge pressures, pipe sizes, elevations and flow. Compare measured head and entered loss corrections.
Gas Spring Force & Lid Torque Calculator