Impedance Matching Calculator & L-Network Smith Chart
Enter measured resistance and signed reactance at a chosen design frequency. Compare every distinct ideal two-element L-network order that matches the load to a positive real reference. Follow the two reactive moves on a normalized Smith chart. Apply the same ideal component values to an optional second measured frequency and impedance to compare reflected power there.
Match a measured impedance with an L-network
Compare valid reactive branches at your design frequency, then check an optional second measured point.
Choose a matching branch
Series inductor · shunt capacitor.
Smith chart from load to source
Follow the two reactive steps from the measured load to the real reference at the chart center.
- Step 1 · shunt
- Step 2 · series
- Second reading with network
Reflected power at the second reading
At 120 MHz, apply the same ideal component values to the entered second impedance.
Review branch values and worksheet CSV
Exact radicands · Load-side 1/10000 S² · Input-side -5000 Ω²
| Branch | Series | Shunt | Input | Numerical |Γ| |
|---|---|---|---|---|
| Load-side shunt + | 79.5775 nH | 15.9155 pF | 50 + j0 Ω | 0 |
| Load-side shunt − | 31.831 pF | 159.155 nH | 50 + j0 Ω | 0 |
How to use this calculator
- Enter the real reference and measured complex impedance at the desired frequency.
- Use positive reactance for an inductive load and negative reactance for a capacitive load.
- Choose a branch and inspect its series and shunt elements and the Smith-chart arcs from load to source.
- If you have a second frequency measurement on the same reference plane, enter that full complex reading to compare modeled reflected power.
- Review the branch ledger and download the exact input and numerical output worksheet.
The Formula
The mathematical logic powering this calculation is:
Use one complex measured passive load Z = R + jX and a real reference resistance R₀. In the series-then-shunt order viewed from the load, first choose total series reactance u = ±√(R(R₀ − R)). The added series reactance is u − X. Then add input shunt susceptance B = u ÷ (R R₀). A negative radicand leaves this order unavailable.
In the shunt-then-series order viewed from the load, write load admittance 1/Z = G + jBᴸ. Find the total shunt susceptance u = ±√(G/R₀ − G²). Add load-side shunt susceptance u − Bᴸ. The resulting impedance has real part R₀ and imaginary part −uR₀/G. Add series reactance uR₀/G to cancel that imaginary part. The sign on a branch denotes its chosen root, not the sign of every component. A zero root appears once. An exact zero added reactance or susceptance omits that element. Equivalent reduced networks appear once.
For angular frequency ω, positive series reactance gives L = Xₛ/ω and negative series reactance gives C = −1/(ω Xₛ). Positive shunt susceptance gives C = B/ω, while negative susceptance gives L = −1/(ω B). The Smith chart plots Γ = (Z − R₀)/(Z + R₀) as each series or shunt element is added from load to source. Its center is the ideal design target Γ = 0. Reflected-power fraction is |Γ|². The second reading applies the same L or C quantities at its own frequency and entered load. It is a discrete comparison on the same real reference plane.
Enter source and load resistance 0.01–1,000,000 Ω, reactance from −1,000,000 to +1,000,000 Ω, and frequency 0.001–100,000 MHz, using plain decimals with up to six decimal places. Branch existence and zero-element decisions use exact arithmetic. Square roots, component values and circuit evaluation use double precision. At extreme ratios the calculated numerical residual is subject to cancellation. This ideal small-signal worksheet leaves out component Q, tolerances, parasitics, self-resonance, impedance variation between readings, and practical component sizing. Physical implementation requires a suitable circuit model and independent measurement.Worked Example
If you input:
- Design: 50 Ω reference and a 100 + j0 Ω load at 100 MHz.
- Second reading: 90 − j10 Ω at 120 MHz.
Result:
The two branches use series 79.5775 nH with shunt 15.9155 pF or series 31.831 pF with shunt 159.155 nH. At 120 MHz the entered direct load reflects 8.62944%. The two branches reflect about 5.05768% and 1.53825% respectively using the same ideal components.
Frequently Asked Questions
How can more than two branches match the same load?
A complex load may qualify for both element orders. Each order can support a positive and a negative algebraic root. Exact collapsed equivalents are counted once.
Why does one branch show an omitted element?
Its ideal solution needs zero added reactance or susceptance at that location. An already matched real load has a direct branch with neither element.
What changes when I select a different branch?
The series and shunt values and plotted route can change. Each viable exact branch shares the ideal target at the design frequency, but its second-reading reflection can differ.
What is the difference between a Smith-chart radius and reflected power?
The radius is the voltage-wave reflection magnitude |Γ|. The squared radius is the fraction of incident power reflected on the stated real reference.
Can two measured points establish the matched bandwidth?
Each reflects modeled behavior at its own entered impedance and frequency. Assess bandwidth on sufficiently sampled measurement data with realistic components.
Why is the numerical reflection residual sometimes very small and nonzero?
The closed-form branch lands on the real reference in exact arithmetic. Numerical evaluation of its component operations can leave finite rounding error, especially at extreme impedance ratios.
Similar Calculators
VSWR Calculator & Reflection Sweep Audit
Compare sampled VSWR or reflection-magnitude readings. Check exact sample bounds against a ceiling, see reflected power and return loss, and identify measurement gaps.
Passive Filter Bode Plot & Load Planner
Plot gain and phase for two loaded RC or series RLC filters. Compare cutoff shifts, half-power frequencies and source-referenced gain at your test frequency.
Series RLC Step Response & Ringdown Calculator
Compare two series RLC transients. Inspect damping, capacitor voltage, current and energy after a constant source step or during source-free ringdown.
Complex Number Plane & Root Branch Calculator
Graph complex numbers, perform exact rectangular arithmetic, compare polar forms and visualize every nth root on the complex plane.