Heating Oil Usage Calculator & Delivery Planner
Use a measured oil-use interval to estimate gallons per heating degree day. Compare mild and cold outlooks or two delivery schedules using the same low and high tank estimates. The chart shows when each scenario crosses the reserve, how a delivery changes inventory, and where demand may exceed available oil.
Compare heating oil use and delivery dates
Calibrate from a measured interval, then compare gauge bounds and delivery timing under two entered weather scenarios.
Forecast assumptions
Enter measured usage and your own forecast assumptions. The same gauge range and reserve apply to both scenarios.
Edit measured use and tank estimates
Edit Scenario A weather and delivery
Blocks run in order. The selected mean is used for every day in its block.
Day 1 is the forecast start. Oil arrives before that day’s use.
Edit Scenario B weather and delivery
Blocks run in order. The selected mean is used for every day in its block.
Day 1 is the forecast start. Oil arrives before that day’s use.
Scenario A holds the reserve through the forecast. Scenario B falls below reserve on Dec 10, 2026.
Calibrated use 0.075 gal per heating degree day, plus 0.4 gal per day for other uses.
Scenario A
102.375 gal
45-day estimated demand
Low estimate stays at or above reserve.
- End stock
- 62.625–72.625 gal
- Latest morning before reserve breach without an earlier delivery
- Dec 24, 2026
- Delivered on Dec 12, 2026
- 60 gal
- Quoted delivery cost
- $220.00
Scenario B
169.875 gal
45-day estimated demand
Low estimate falls below reserve on Dec 10, 2026.
Low estimate leaves 4.875 gal unmet, first on Jan 1, 2027.
- End stock
- 0–5.125 gal
- Latest morning before reserve breach without an earlier delivery
- Dec 10, 2026
- Delivered on Dec 12, 2026
- 60 gal
- Quoted delivery cost
- $220.00
Oil inventory and reserve by day
Each shaded band spans the low and high starting estimates. A vertical rise marks a modeled delivery.
Horizontal axis is the forecast date. Vertical axis is usable oil in US gallons. The daily ledger lists both paths.
How much oil can fit on the delivery day?
Scenario A
22.375 gal needed to hold the low estimate at or above reserve after delivery.
137.325 gal is the largest fixed order that fits both gauge estimates on that morning.
Scenario B
89.875 gal needed to hold the low estimate at or above reserve after delivery.
171.825 gal is the largest fixed order that fits both gauge estimates on that morning.
Low estimate crossed reserve before delivery on Dec 10, 2026.
Oil usage and delivery ledger
Open daily forecast
Volume ranges show the minimum and maximum across the two gauge estimates. The CSV identifies each path.
| Date | Mean (°F) | Demand | Opening | Delivered | Closing | Unmet |
|---|---|---|---|---|---|---|
| Nov 19, 2026 | 40 | 2.275 gal | 105–115 gal | 0 gal | 102.725–112.725 gal | 0 gal |
| Nov 20, 2026 | 40 | 2.275 gal | 102.725–112.725 gal | 0 gal | 100.45–110.45 gal | 0 gal |
| Nov 21, 2026 | 40 | 2.275 gal | 100.45–110.45 gal | 0 gal | 98.175–108.175 gal | 0 gal |
| Nov 22, 2026 | 40 | 2.275 gal | 98.175–108.175 gal | 0 gal | 95.9–105.9 gal | 0 gal |
| Nov 23, 2026 | 40 | 2.275 gal | 95.9–105.9 gal | 0 gal | 93.625–103.625 gal | 0 gal |
| Nov 24, 2026 | 40 | 2.275 gal | 93.625–103.625 gal | 0 gal | 91.35–101.35 gal | 0 gal |
| Nov 25, 2026 | 40 | 2.275 gal | 91.35–101.35 gal | 0 gal | 89.075–99.075 gal | 0 gal |
| Nov 26, 2026 | 40 | 2.275 gal | 89.075–99.075 gal | 0 gal | 86.8–96.8 gal | 0 gal |
| Nov 27, 2026 | 40 | 2.275 gal | 86.8–96.8 gal | 0 gal | 84.525–94.525 gal | 0 gal |
| Nov 28, 2026 | 40 | 2.275 gal | 84.525–94.525 gal | 0 gal | 82.25–92.25 gal | 0 gal |
| Nov 29, 2026 | 40 | 2.275 gal | 82.25–92.25 gal | 0 gal | 79.975–89.975 gal | 0 gal |
| Nov 30, 2026 | 40 | 2.275 gal | 79.975–89.975 gal | 0 gal | 77.7–87.7 gal | 0 gal |
| Dec 1, 2026 | 40 | 2.275 gal | 77.7–87.7 gal | 0 gal | 75.425–85.425 gal | 0 gal |
| Dec 2, 2026 | 40 | 2.275 gal | 75.425–85.425 gal | 0 gal | 73.15–83.15 gal | 0 gal |
| Dec 3, 2026 | 40 | 2.275 gal | 73.15–83.15 gal | 0 gal | 70.875–80.875 gal | 0 gal |
| Dec 4, 2026 | 40 | 2.275 gal | 70.875–80.875 gal | 0 gal | 68.6–78.6 gal | 0 gal |
| Dec 5, 2026 | 40 | 2.275 gal | 68.6–78.6 gal | 0 gal | 66.325–76.325 gal | 0 gal |
| Dec 6, 2026 | 40 | 2.275 gal | 66.325–76.325 gal | 0 gal | 64.05–74.05 gal | 0 gal |
| Dec 7, 2026 | 40 | 2.275 gal | 64.05–74.05 gal | 0 gal | 61.775–71.775 gal | 0 gal |
| Dec 8, 2026 | 40 | 2.275 gal | 61.775–71.775 gal | 0 gal | 59.5–69.5 gal | 0 gal |
| Dec 9, 2026 | 40 | 2.275 gal | 59.5–69.5 gal | 0 gal | 57.225–67.225 gal | 0 gal |
| Dec 10, 2026 | 40 | 2.275 gal | 57.225–67.225 gal | 0 gal | 54.95–64.95 gal | 0 gal |
| Dec 11, 2026 | 40 | 2.275 gal | 54.95–64.95 gal | 0 gal | 52.675–62.675 gal | 0 gal |
| Dec 12, 2026 | 40 | 2.275 gal | 52.675–62.675 gal | 60 gal | 110.4–120.4 gal | 0 gal |
| Dec 13, 2026 | 40 | 2.275 gal | 110.4–120.4 gal | 0 gal | 108.125–118.125 gal | 0 gal |
| Dec 14, 2026 | 40 | 2.275 gal | 108.125–118.125 gal | 0 gal | 105.85–115.85 gal | 0 gal |
| Dec 15, 2026 | 40 | 2.275 gal | 105.85–115.85 gal | 0 gal | 103.575–113.575 gal | 0 gal |
| Dec 16, 2026 | 40 | 2.275 gal | 103.575–113.575 gal | 0 gal | 101.3–111.3 gal | 0 gal |
| Dec 17, 2026 | 40 | 2.275 gal | 101.3–111.3 gal | 0 gal | 99.025–109.025 gal | 0 gal |
| Dec 18, 2026 | 40 | 2.275 gal | 99.025–109.025 gal | 0 gal | 96.75–106.75 gal | 0 gal |
| Dec 19, 2026 | 40 | 2.275 gal | 96.75–106.75 gal | 0 gal | 94.475–104.475 gal | 0 gal |
| Dec 20, 2026 | 40 | 2.275 gal | 94.475–104.475 gal | 0 gal | 92.2–102.2 gal | 0 gal |
| Dec 21, 2026 | 40 | 2.275 gal | 92.2–102.2 gal | 0 gal | 89.925–99.925 gal | 0 gal |
| Dec 22, 2026 | 40 | 2.275 gal | 89.925–99.925 gal | 0 gal | 87.65–97.65 gal | 0 gal |
| Dec 23, 2026 | 40 | 2.275 gal | 87.65–97.65 gal | 0 gal | 85.375–95.375 gal | 0 gal |
| Dec 24, 2026 | 40 | 2.275 gal | 85.375–95.375 gal | 0 gal | 83.1–93.1 gal | 0 gal |
| Dec 25, 2026 | 40 | 2.275 gal | 83.1–93.1 gal | 0 gal | 80.825–90.825 gal | 0 gal |
| Dec 26, 2026 | 40 | 2.275 gal | 80.825–90.825 gal | 0 gal | 78.55–88.55 gal | 0 gal |
| Dec 27, 2026 | 40 | 2.275 gal | 78.55–88.55 gal | 0 gal | 76.275–86.275 gal | 0 gal |
| Dec 28, 2026 | 40 | 2.275 gal | 76.275–86.275 gal | 0 gal | 74–84 gal | 0 gal |
| Dec 29, 2026 | 40 | 2.275 gal | 74–84 gal | 0 gal | 71.725–81.725 gal | 0 gal |
| Dec 30, 2026 | 40 | 2.275 gal | 71.725–81.725 gal | 0 gal | 69.45–79.45 gal | 0 gal |
| Dec 31, 2026 | 40 | 2.275 gal | 69.45–79.45 gal | 0 gal | 67.175–77.175 gal | 0 gal |
| Jan 1, 2027 | 40 | 2.275 gal | 67.175–77.175 gal | 0 gal | 64.9–74.9 gal | 0 gal |
| Jan 2, 2027 | 40 | 2.275 gal | 64.9–74.9 gal | 0 gal | 62.625–72.625 gal | 0 gal |
Show selectable CSV
How to use this calculator
- Enter the forecast start date and one measured oil-use interval. Use base-65°F heating degree days from the same dates.
- Enter average daily oil use for domestic hot water or other non-space heating. Use zero if the measured oil served space heating alone.
- Enter low and high estimates of current usable oil, the confirmed fill limit, and your planning reserve.
- For each scenario, enter daily mean-temperature blocks. Choose no delivery, a fixed order, or a fill to the entered limit, and enter the delivery date index and quote if applicable.
- Compare the low and high stock bands, the first reserve or unmet-demand dates, and the modeled amount and cost of each order. Open or export the daily ledger for the full path.
The Formula
The mathematical logic powering this calculation is:
Use oil consumed over a measured interval, its length in days, and base-65°F heating degree days for the same dates. Remove the estimated non-space-heating gallons per day multiplied by the number of days. Divide the remaining heating gallons by the entered degree days. The worksheet does not infer separate home heating and hot-water loads from a single interval.
For each forecast day, base-65°F heating degree days equal max(0, 65 − entered daily mean in °F). Predicted gallons equal the entered non-space-heating rate plus gallons per degree day times daily degree days. A block uses the same daily mean for every day in that block. Two starting stock estimates produce the low and high paths. Daily demand reduces each path to zero at minimum. An amount beyond the stock is recorded as unmet demand. The reserve is crossed only when closing stock is strictly below the entered reserve. A start already below reserve is shown separately.
The optional delivery arrives before use on its selected day. The delivered volume is the requested amount capped by room to the entered fill limit. Fill-to-limit mode uses all that room. The estimate charges the entered price per delivered gallon plus the entered delivery fee if some oil is delivered, with the total rounded half up to cents. The two quote amounts follow the two gauge paths. Actual orders and supplier fees can work differently.
The low path needs the positive part of reserve plus remaining demand minus stock before delivery. The maximum fixed quantity that fits both gauge estimates uses room on the high-stock path. Check both numbers. A later delivery can replenish the tank without repairing an earlier reserve breach. The latest reserve-safe delivery morning comes from the low starting estimate without any earlier delivery. It is the morning of the first modeled day whose closing amount would fall below reserve.
The tool uses US gallons and °F, with up to four decimal places in input quantities. A forecast has one to eight temperature blocks and up to 180 days per scenario. Use a positive fill limit confirmed for your system, a known starting range, and entered mean temperatures. Day 1 is the chosen start date. The temperature outlook, historical use and gauge range are user inputs. Results estimate oil demand and the entered quote. They do not infer tank capacity, gauge accuracy, weather or permitted operating levels.Worked Example
If you input:
- Observed days: 40 with 960 heating degree days
- Measured oil used (gal): 88
- Other oil use per day (gal): 0.4
- Starting stock and reserve (gal): 105–115 with a 25 gallon reserve
- Weather and delivery: 45 days at 40°F or 20°F. Order 60 gallons on day 24.
Result:
Measured non-space-heating use is 16 gal, leaving 72 gal for space heating. The coefficient is 0.075 gal per heating degree day. The 40°F path uses 102.375 gal and ends at 62.625–72.625 gal. At 20°F, the low starting path falls below reserve on Dec 10, before the delivery on Dec 12, and later has 4.875 gal of unmet modeled demand. Moving the cold-weather delivery to day 22 and entering 90 gal leaves 25.125–35.125 gal at the end.
Frequently Asked Questions
What is a heating degree day?
It measures how far a day's mean temperature is below a base temperature. At a 65°F base, a day averaging 55°F has 10 heating degree days. Days at or above the base contribute zero.
Does a recent delivery tell me how much oil I used?
Use a measured consumption interval. If both refills reach the same confirmed level, the later delivered amount can estimate the oil used between them. Different fill levels require a separate stock reconciliation.
Why enter two starting estimates?
A low/high range shows the effect of uncertainty in the current tank reading. The lower path may cross the reserve earlier, while the higher path can leave less room for a scheduled order.
Why is the modeled delivery smaller than my order?
The model limits delivered gallons to the room below the entered fill limit. The quote uses delivered gallons and adds the entered flat fee when more than zero gallons are modeled. Check the supplier's order terms for any minimum or trip charge.
Why does a late delivery leave a reserve warning after the tank is refilled?
The dates describe the full daily path. The order can raise later stock while the earlier closing reserve breach remains part of the forecast history.
Can I reuse the coefficient in a different building or season?
The coefficient comes from your historical interval and assumptions about other oil use. Equipment changes, different indoor temperatures, and atypical usage can change the relationship. Use the scenario comparison to see how different entered conditions affect timing.
Similar Calculators
Propane Usage & Supply Planner
Estimate propane usage across appliances and changing daily routines. Compare fuel demand, reserve timing, supply shortfalls and replacement costs with exact ledgers.
Room Heat Loss & Retrofit Calculator
Explore room heat loss and sensible cooling, compare envelope and ventilation retrofits, and visualize heat flows and outdoor-temperature sensitivity with exact CSV ledgers.
Electricity Cost Calculator
Estimate appliance electricity cost from wattage, daily use, electricity rate, and billing fees.
Tankless Water Heater Demand & Sizing Planner
Compare tankless water-heater demand across fixture schedules and seasonal inlet temperatures. Visualize peak heat, flow limits, activation gaps and exact energy costs.