Heating Oil Usage Calculator & Delivery Planner

Use a measured oil-use interval to estimate gallons per heating degree day. Compare mild and cold outlooks or two delivery schedules using the same low and high tank estimates. The chart shows when each scenario crosses the reserve, how a delivery changes inventory, and where demand may exceed available oil.

Heating fuel planning

Compare heating oil use and delivery dates

Forecast assumptions

Enter measured usage and your own forecast assumptions. The same gauge range and reserve apply to both scenarios.

Edit measured use and tank estimates
Edit Scenario A weather and delivery

Blocks run in order. The selected mean is used for every day in its block.

Block 1

Day 1 is the forecast start. Oil arrives before that day’s use.

Edit Scenario B weather and delivery

Blocks run in order. The selected mean is used for every day in its block.

Block 1

Day 1 is the forecast start. Oil arrives before that day’s use.

Scenario A holds the reserve through the forecast. Scenario B falls below reserve on Dec 10, 2026.

Calibrated use 0.075 gal per heating degree day, plus 0.4 gal per day for other uses.

Scenario A

102.375 gal

45-day estimated demand

Low estimate stays at or above reserve.

End stock
62.625–72.625 gal
Latest morning before reserve breach without an earlier delivery
Dec 24, 2026
Delivered on Dec 12, 2026
60 gal
Quoted delivery cost
$220.00

Scenario B

169.875 gal

45-day estimated demand

Low estimate falls below reserve on Dec 10, 2026.

Low estimate leaves 4.875 gal unmet, first on Jan 1, 2027.

End stock
0–5.125 gal
Latest morning before reserve breach without an earlier delivery
Dec 10, 2026
Delivered on Dec 12, 2026
60 gal
Quoted delivery cost
$220.00

Oil inventory and reserve by day

Each shaded band spans the low and high starting estimates. A vertical rise marks a modeled delivery.

━ Scenario A┄ Scenario B··· Reserve 25 gal
Forecast heating oil inventory in US gallonsStarting low and high gauge bounds are 105–115 gal. Scenario A holds the reserve through the forecast. Scenario B falls below reserve on Dec 10, 2026. The selected reserve is 25 gal.122.680Nov 19Jan 2

Horizontal axis is the forecast date. Vertical axis is usable oil in US gallons. The daily ledger lists both paths.

How much oil can fit on the delivery day?

Scenario A

22.375 gal needed to hold the low estimate at or above reserve after delivery.

137.325 gal is the largest fixed order that fits both gauge estimates on that morning.

Scenario B

89.875 gal needed to hold the low estimate at or above reserve after delivery.

171.825 gal is the largest fixed order that fits both gauge estimates on that morning.

Low estimate crossed reserve before delivery on Dec 10, 2026.

Oil usage and delivery ledger

Open daily forecast

Volume ranges show the minimum and maximum across the two gauge estimates. The CSV identifies each path.

Scenario A forecast by day
DateMean (°F)DemandOpeningDeliveredClosingUnmet
Nov 19, 2026402.275 gal105–115 gal0 gal102.725–112.725 gal0 gal
Nov 20, 2026402.275 gal102.725–112.725 gal0 gal100.45–110.45 gal0 gal
Nov 21, 2026402.275 gal100.45–110.45 gal0 gal98.175–108.175 gal0 gal
Nov 22, 2026402.275 gal98.175–108.175 gal0 gal95.9–105.9 gal0 gal
Nov 23, 2026402.275 gal95.9–105.9 gal0 gal93.625–103.625 gal0 gal
Nov 24, 2026402.275 gal93.625–103.625 gal0 gal91.35–101.35 gal0 gal
Nov 25, 2026402.275 gal91.35–101.35 gal0 gal89.075–99.075 gal0 gal
Nov 26, 2026402.275 gal89.075–99.075 gal0 gal86.8–96.8 gal0 gal
Nov 27, 2026402.275 gal86.8–96.8 gal0 gal84.525–94.525 gal0 gal
Nov 28, 2026402.275 gal84.525–94.525 gal0 gal82.25–92.25 gal0 gal
Nov 29, 2026402.275 gal82.25–92.25 gal0 gal79.975–89.975 gal0 gal
Nov 30, 2026402.275 gal79.975–89.975 gal0 gal77.7–87.7 gal0 gal
Dec 1, 2026402.275 gal77.7–87.7 gal0 gal75.425–85.425 gal0 gal
Dec 2, 2026402.275 gal75.425–85.425 gal0 gal73.15–83.15 gal0 gal
Dec 3, 2026402.275 gal73.15–83.15 gal0 gal70.875–80.875 gal0 gal
Dec 4, 2026402.275 gal70.875–80.875 gal0 gal68.6–78.6 gal0 gal
Dec 5, 2026402.275 gal68.6–78.6 gal0 gal66.325–76.325 gal0 gal
Dec 6, 2026402.275 gal66.325–76.325 gal0 gal64.05–74.05 gal0 gal
Dec 7, 2026402.275 gal64.05–74.05 gal0 gal61.775–71.775 gal0 gal
Dec 8, 2026402.275 gal61.775–71.775 gal0 gal59.5–69.5 gal0 gal
Dec 9, 2026402.275 gal59.5–69.5 gal0 gal57.225–67.225 gal0 gal
Dec 10, 2026402.275 gal57.225–67.225 gal0 gal54.95–64.95 gal0 gal
Dec 11, 2026402.275 gal54.95–64.95 gal0 gal52.675–62.675 gal0 gal
Dec 12, 2026402.275 gal52.675–62.675 gal60 gal110.4–120.4 gal0 gal
Dec 13, 2026402.275 gal110.4–120.4 gal0 gal108.125–118.125 gal0 gal
Dec 14, 2026402.275 gal108.125–118.125 gal0 gal105.85–115.85 gal0 gal
Dec 15, 2026402.275 gal105.85–115.85 gal0 gal103.575–113.575 gal0 gal
Dec 16, 2026402.275 gal103.575–113.575 gal0 gal101.3–111.3 gal0 gal
Dec 17, 2026402.275 gal101.3–111.3 gal0 gal99.025–109.025 gal0 gal
Dec 18, 2026402.275 gal99.025–109.025 gal0 gal96.75–106.75 gal0 gal
Dec 19, 2026402.275 gal96.75–106.75 gal0 gal94.475–104.475 gal0 gal
Dec 20, 2026402.275 gal94.475–104.475 gal0 gal92.2–102.2 gal0 gal
Dec 21, 2026402.275 gal92.2–102.2 gal0 gal89.925–99.925 gal0 gal
Dec 22, 2026402.275 gal89.925–99.925 gal0 gal87.65–97.65 gal0 gal
Dec 23, 2026402.275 gal87.65–97.65 gal0 gal85.375–95.375 gal0 gal
Dec 24, 2026402.275 gal85.375–95.375 gal0 gal83.1–93.1 gal0 gal
Dec 25, 2026402.275 gal83.1–93.1 gal0 gal80.825–90.825 gal0 gal
Dec 26, 2026402.275 gal80.825–90.825 gal0 gal78.55–88.55 gal0 gal
Dec 27, 2026402.275 gal78.55–88.55 gal0 gal76.275–86.275 gal0 gal
Dec 28, 2026402.275 gal76.275–86.275 gal0 gal74–84 gal0 gal
Dec 29, 2026402.275 gal74–84 gal0 gal71.725–81.725 gal0 gal
Dec 30, 2026402.275 gal71.725–81.725 gal0 gal69.45–79.45 gal0 gal
Dec 31, 2026402.275 gal69.45–79.45 gal0 gal67.175–77.175 gal0 gal
Jan 1, 2027402.275 gal67.175–77.175 gal0 gal64.9–74.9 gal0 gal
Jan 2, 2027402.275 gal64.9–74.9 gal0 gal62.625–72.625 gal0 gal
Show selectable CSV

How to use this calculator

  1. Enter the forecast start date and one measured oil-use interval. Use base-65°F heating degree days from the same dates.
  2. Enter average daily oil use for domestic hot water or other non-space heating. Use zero if the measured oil served space heating alone.
  3. Enter low and high estimates of current usable oil, the confirmed fill limit, and your planning reserve.
  4. For each scenario, enter daily mean-temperature blocks. Choose no delivery, a fixed order, or a fill to the entered limit, and enter the delivery date index and quote if applicable.
  5. Compare the low and high stock bands, the first reserve or unmet-demand dates, and the modeled amount and cost of each order. Open or export the daily ledger for the full path.

The Formula

The mathematical logic powering this calculation is:

Use oil consumed over a measured interval, its length in days, and base-65°F heating degree days for the same dates. Remove the estimated non-space-heating gallons per day multiplied by the number of days. Divide the remaining heating gallons by the entered degree days. The worksheet does not infer separate home heating and hot-water loads from a single interval.

For each forecast day, base-65°F heating degree days equal max(0, 65 − entered daily mean in °F). Predicted gallons equal the entered non-space-heating rate plus gallons per degree day times daily degree days. A block uses the same daily mean for every day in that block. Two starting stock estimates produce the low and high paths. Daily demand reduces each path to zero at minimum. An amount beyond the stock is recorded as unmet demand. The reserve is crossed only when closing stock is strictly below the entered reserve. A start already below reserve is shown separately.

The optional delivery arrives before use on its selected day. The delivered volume is the requested amount capped by room to the entered fill limit. Fill-to-limit mode uses all that room. The estimate charges the entered price per delivered gallon plus the entered delivery fee if some oil is delivered, with the total rounded half up to cents. The two quote amounts follow the two gauge paths. Actual orders and supplier fees can work differently.

The low path needs the positive part of reserve plus remaining demand minus stock before delivery. The maximum fixed quantity that fits both gauge estimates uses room on the high-stock path. Check both numbers. A later delivery can replenish the tank without repairing an earlier reserve breach. The latest reserve-safe delivery morning comes from the low starting estimate without any earlier delivery. It is the morning of the first modeled day whose closing amount would fall below reserve.

The tool uses US gallons and °F, with up to four decimal places in input quantities. A forecast has one to eight temperature blocks and up to 180 days per scenario. Use a positive fill limit confirmed for your system, a known starting range, and entered mean temperatures. Day 1 is the chosen start date. The temperature outlook, historical use and gauge range are user inputs. Results estimate oil demand and the entered quote. They do not infer tank capacity, gauge accuracy, weather or permitted operating levels.

Worked Example

If you input:

  • Observed days: 40 with 960 heating degree days
  • Measured oil used (gal): 88
  • Other oil use per day (gal): 0.4
  • Starting stock and reserve (gal): 105–115 with a 25 gallon reserve
  • Weather and delivery: 45 days at 40°F or 20°F. Order 60 gallons on day 24.

Result:

Measured non-space-heating use is 16 gal, leaving 72 gal for space heating. The coefficient is 0.075 gal per heating degree day. The 40°F path uses 102.375 gal and ends at 62.625–72.625 gal. At 20°F, the low starting path falls below reserve on Dec 10, before the delivery on Dec 12, and later has 4.875 gal of unmet modeled demand. Moving the cold-weather delivery to day 22 and entering 90 gal leaves 25.125–35.125 gal at the end.

Frequently Asked Questions

What is a heating degree day?

It measures how far a day's mean temperature is below a base temperature. At a 65°F base, a day averaging 55°F has 10 heating degree days. Days at or above the base contribute zero.

Does a recent delivery tell me how much oil I used?

Use a measured consumption interval. If both refills reach the same confirmed level, the later delivered amount can estimate the oil used between them. Different fill levels require a separate stock reconciliation.

Why enter two starting estimates?

A low/high range shows the effect of uncertainty in the current tank reading. The lower path may cross the reserve earlier, while the higher path can leave less room for a scheduled order.

Why is the modeled delivery smaller than my order?

The model limits delivered gallons to the room below the entered fill limit. The quote uses delivered gallons and adds the entered flat fee when more than zero gallons are modeled. Check the supplier's order terms for any minimum or trip charge.

Why does a late delivery leave a reserve warning after the tank is refilled?

The dates describe the full daily path. The order can raise later stock while the earlier closing reserve breach remains part of the forecast history.

Can I reuse the coefficient in a different building or season?

The coefficient comes from your historical interval and assumptions about other oil use. Equipment changes, different indoor temperatures, and atypical usage can change the relationship. Use the scenario comparison to see how different entered conditions affect timing.

Similar Calculators