Heat Tape Calculator for Length, Current & Cost

Audit already specified pipe heat cable runs against the documented maximum circuit length, supply voltage, and simultaneous current allowances. The comparison keeps powered lengths separate from the cable quantities on each written quote.

Heat cable audit

Compare heat tape length and current

Documented supply and current allowances
Already specified powered circuits
Option A
Option B
Only Option B meets all entered cable and current limits.
Option A entered purchase
$516.25
125 ft to purchase · Outside entered limits
Option B entered purchase
$579.70
117 ft to purchase · Meets entered limits

Powered lengths and current limits

Each marker is an entered limit. Amber bars exceed it. The current view assumes the entered circuits start together.

Option A current

Running4.914 / 7 A
Startup10.53 / 10.5 A

Entered voltages agree.

Option B current

Running5.382 / 7 A
Startup9.945 / 10.5 A

Entered voltages agree.

Option A circuit lengths

Circuit 128 / 50 ft
Circuit 237 / 50 ft
Circuit 352 / 50 ft

Option B circuit lengths

Circuit 128 / 60 ft
Circuit 237 / 60 ft
Circuit 352 / 60 ft
Review purchase lengths and exact cable CSV
  • Option A · 125 ft to purchase for 117 ft powered
  • Option B · 117 ft to purchase for 117 ft powered

How to use this calculator

  1. Enter the approved supply voltage and the documented running and startup current allowances.
  2. Enter each already specified powered circuit length.
  3. Copy the applicable maximum length, voltage and current rates from each option's documentation, along with the written prices and purchase increments.
  4. Compare length and current charts, review purchased versus powered footage, and export the exact audit.

The Formula

The mathematical logic powering this calculation is:

Enter lengths for circuits that have already been specified. For each cut-to-length product, use the cable documentation for that exact product and design condition, including the applicable supply voltage and maximum length per circuit. The audit compares each entered length with that maximum. A circuit at the exact entered maximum meets the length check.
Enter documented running and startup rates in amps per 100 ft only when those rates apply linearly to your specified lengths in that design condition. Total current for each state equals the rate times total powered length divided by 100. The worksheet assumes all entered circuits operate or start together and compares their sums with the respective entered allowances. All comparisons use exact input-derived values.
For purchasing, round each run's length up to the quote's increment, then add the individual rounded quantities. The difference is unpowered purchase extra. Calculate purchase cost as the rounded purchase quantity times the unit price, rounded half up to cents, plus stated fixed charges.
Enter one to six powered lengths of 0.01–2,000 ft, voltages of 12–600 V and current rates or allowances from 0–1,000 A in the indicated units. This worksheet checks documented limits supplied by the user. Actual heat loss, a product's suitability, supported circuits, temperature-dependent output, installation, circuit protection and electrical design require separate confirmation.

Worked Example

If you input:

  • Circuits: 28, 37 and 52 ft powered at 120 V.
  • Simultaneous allowances: 7 A running and 10.5 A startup.
  • Option A: 50 ft per circuit, 4.2 A running and 9 A startup per 100 ft, $3.25/ft and $110 fixed, ordered in 5-ft increments per run.
  • Option B: 60 ft per circuit, 4.6 A running and 8.5 A startup per 100 ft, $4.10/ft and $100 fixed, ordered in 1-ft increments per run.

Result:

The 52-ft circuit exceeds A's 50-ft limit and A draws an estimated 10.53 A at startup. B passes the entered checks with 9.945 A at startup and costs $579.70.

Frequently Asked Questions

Why can the startup and running comparisons differ?

The two entered rates represent separate conditions. Each total is compared with its respective simultaneous current allowance.

Does purchased length change the current estimate?

Current is calculated from the entered powered footage. Purchase rounding may leave material that remains unused.

Can multiple short runs offset one above the maximum?

The length limit is checked for each circuit. One circuit over its entered maximum fails the length check even if the sum of currents is within the allowances.

Where do I find the maximum heat cable circuit length?

Use the documentation for the specific cable and documented design conditions. Published maximums can vary with cable type, voltage and starting temperature.

Similar Calculators