Grain Bin Capacity & Inventory Calculator

Compare two round grain bins or two readings from the same bin. Use the recorded inside diameter, eave and roof dimensions, and measured grain heights at the wall and center. A tapered hopper can be full or entered separately at a partial fill height. The cutaways show the entered shapes and the ledger separates grain in the hopper, upright cylinder and roof.

Grain inventory

Compare grain bin capacity and inventory

Use measured bin dimensions and grain levels to compare volume, geometric space, and estimated mass for two bins or two readings.

Inventory and unfilled space

The bars share one volume scale. Hatched space is the unfilled part of the entered geometry.

Bin A · Peaked surface

9,088.09 US bu

11,309.73 ft³ · 80% of geometric envelope

Unfilled space
2,272.02 US bu
Geometric envelope
11,360.12 US bu
Estimated mass
249.92 short tons

Bin B · Dished surface

6,816.07 US bu

8,482.3 ft³ · 60% of geometric envelope

Unfilled space
4,544.05 US bu
Geometric envelope
11,360.12 US bu
Estimated mass
187.44 short tons

Bin B minus Bin A inventory −2,272.02 US bu

Edit bin measurements

Use the flat floor or the base of the upright sidewall as zero. Measure the roof rise from the eave.

Enter both grain readings above the sidewall base. Their difference defines the peak or dish.

Use the measured or assumed pounds per physical bushel of grain.

Grain bin profiles

Both cutaways use the same width and height scales. The lower dashed line marks the sidewall base.

Bin A
Bin A cross-section30 ft inside diameter. Grain is 14 ft at the wall and 20 ft at the center. Amber grain fills 80% of the envelope.

Grain is 14 ft at the wall and 20 ft at the center.

30 ft inside diameter · Peaked surface

Bin B
Bin B cross-section30 ft inside diameter. Grain is 14 ft at the wall and 8 ft at the center. Amber grain fills 60% of the envelope.

Grain is 14 ft at the wall and 8 ft at the center.

30 ft inside diameter · Dished surface

Show bin volume ledger
Bin A
Bin sectionGeometric volumeGrain volumeUS bu
Hopper0 ft³0 ft³0 US bu
Upright cylinder12,723.45 ft³11,257.37 ft³9,046.02 US bu
Roof envelope1,413.72 ft³52.36 ft³42.07 US bu

Wall-level grain volume 9,896.02 ft³. Signed center adjustment +1,413.72 ft³.

Estimated mass 499,845.18 lb at 55 lb per US bu.

Bin B
Bin sectionGeometric volumeGrain volumeUS bu
Hopper0 ft³0 ft³0 US bu
Upright cylinder12,723.45 ft³8,482.3 ft³6,816.07 US bu
Roof envelope1,413.72 ft³0 ft³0 US bu

Wall-level grain volume 9,896.02 ft³. Signed center adjustment −1,413.72 ft³.

Estimated mass 374,883.89 lb at 55 lb per US bu.

Export the bin comparison

Save entered dimensions, geometric volumes, mass assumptions, and all profile coordinates.

Download grain bin CSV
Show selectable CSV

How to use this calculator

  1. Choose Peaked vs dished or Hopper-only vs above hopper. Select Bin A or Bin B to edit its dimensions.
  2. Enter the recorded inside diameter, the eave height above the sidewall base and the roof rise above the eave. Use zero roof rise to stop the estimate at the eave.
  3. Choose Flat floor or Hopper below sidewall, then enter wall and center readings from the shared datum. For grain below the sidewall, choose the hopper-only reading and enter the height above the hopper bottom.
  4. Enable Estimate mass from bulk weight when you have a measured or assumed number of pounds per physical US bushel.
  5. Compare the profiles, open Show bin volume ledger, and download grain bin CSV for dimensions, section totals, weight assumptions and profile coordinates.

The Formula

The mathematical logic powering this calculation is:

For diameter D feet the upright cross-sectional area A equals πD²/4. The volumes of the geometric envelope are A × eave height for the cylinder, A × roof rise/3 for the roof, and π × hopper depth × (D² + Dd + d²)/12 for a hopper with lower diameter d. The datum is the flat floor or the junction between the hopper and upright walls. Hoppers extend down from it and the roof rises above the eave.
A wall and center reading gives a symmetric, straight sloped surface from the wall to the center. Above the datum, volume equals A × wall reading plus A × (center reading − wall reading)/3. The adjustment is positive for a peak and negative for a dish. In this mode a hopper is full. If the center is above the eave, let h be the center height above that line and s the center height minus the wall height of the grain. The tip diameter at the eave is D × h/s, and the modeled volume above the eave is π(D × h/s)²h/12. Subtract that from the above-datum total to get the grain volume inside the upright cylinder.
Hopper-only mode uses a level surface. At height t above the lower lip in a depth H hopper, diameter at the fill line equals d + (D − d)t/H. The occupied bottom segment is a frustum of height t with the two entered or derived diameters. At t = H this equals the full hopper volume.
Unfilled space is the geometric envelope minus the occupied volume. Convert cubic feet to physical US dry bushels using 2,150.42 cubic inches per bushel and 1,728 cubic inches per cubic foot. Optional mass in pounds equals physical bushels × entered pounds per physical bushel. A US short ton equals 2,000 pounds. Source examples that use rounded 0.8 bushels per cubic foot give slightly different estimates. The calculation applies neither a packing factor nor an assumed commodity density.
Diameter and eave height are 1–200 ft. Roof rise is 0–100 ft. A hopper extends 0.0001–100 ft below the datum and uses a lower diameter from 0 through D. Wall reading is 0 through the eave, center reading is 0 through eave plus roof rise, and hopper-only fill is 0 through its depth. Bulk weight supports 1–200 lb per US bu. Inputs allow up to four decimal places.
This worksheet estimates a cylindrical bin with an optional conical roof and tapered lower segment from recorded geometry. Geometric space includes any entered roof envelope. Operational or structural capacity, filling limits, handling instructions, packing, moisture and commercial bushel weights are outside this model.

Worked Example

If you input:

  • Both bins: 30 ft diameter, 18 ft eave, 6 ft roof rise, flat floor, 14 ft grain at wall
  • Bin A: 20 ft grain at center
  • Bin B: 8 ft grain at center
  • Illustrative bulk weight: 55 lb per physical US bushel

Result:

Bin A holds 9,088.09 US bu and Bin B holds 6,816.07 US bu. The 6 ft peak and 6 ft dish create a difference of 2,272.02 US bu at equal wall height. At the example bulk weight, the modeled masses are 249.92 and 187.44 US short tons.

Frequently Asked Questions

How many bushels are in a round grain bin?

For level grain in the upright cylinder, multiply π times the squared radius by the grain height. Add any modeled hopper volume and divide cubic feet by about 1.244456 to calculate physical US dry bushels.

How much does a peak change the estimate?

The modeled peak adds one third of the center rise as an average depth over the bin. A center dish uses that same relationship with a negative depth difference.

Can this calculate a partially filled hopper?

Yes. Use the hopper-only reading to enter the level height above the lower lip. The upper diameter of that occupied frustum is interpolated from the dimensions of the hopper.

Why do two equal wall readings give different grain volumes?

The center reading changes the extent of the sloping surface. In the default example both wall readings are 14 ft, and raising versus lowering the center by 6 ft changes the inventory by about 2,272 physical US bushels.

Does the bushel estimate use the grain’s trade weight?

The bushels are a volume measure with a fixed number of cubic inches. The optional mass reads the weight per physical bushel you supply. Commercial bushel reporting follows its own commodity and transaction basis.

What does geometric unfilled space include?

It includes unused volume in the entered cylinder, lower hopper and roof. The geometry describes available physical space in that model. Any operational fill limit comes from the applicable equipment and site requirements.

Similar Calculators