Gambrel Roof Calculator & Attic Headroom Planner

Compare two symmetric gambrel roof profiles against the same span and attic floor. Enter both slopes and where each profile changes pitch. See the ridge and break heights, roof-face lengths and area, and how much centered attic width clears the height you enter.

Gambrel profiles

Compare headroom under two roof profiles

Use both pitches and the slope break to check centered attic width at your target height.

Clear width. Profile A: 16 ft. Profile B: 18 ft.

Attic clearance comparison

Target 16 ft wide at 7 ft clear height.

Profile A

Target width and height fit

Clear width at target height
16 ft
Ridge above attic floor
11.5 ft
Clear height at target width
7 ft
Clearance line position
slope break

Profile B

Target width and height fit

Clear width at target height
18 ft
Ridge above attic floor
10.5 ft
Clear height at target width
7.33 ft
Clearance line position
slope break
Roof cross-sections

The clearance line is 7.5 ft above the attic floor, including the vertical allowance.

  • Profile A
  • Profile B
  • Clearance line
Shared dimensions and clearance
Profile A
Profile B
Gambrel geometry ledger

Roof-face measurements run from eaves to ridge and exclude overhangs. Fit uses unrounded dimensions.

Gambrel profile dimensions and clearance
MeasurementProfile AProfile B
Lower horizontal run4 ft3 ft
Upper horizontal run8 ft9 ft
Lower rise6 ft6 ft
Upper rise4 ft3 ft
Total rise above eave10 ft9 ft
Slope break above floor7.5 ft7.5 ft
Ridge above floor11.5 ft10.5 ft
Lower roof-face length7.21 ft6.71 ft
Upper roof-face length8.94 ft9.49 ft
Lower slope angle56.31 °63.43 °
Upper slope angle26.57 °18.43 °
All roof-face area969.32 ft²971.7 ft²
Clear width at target height16 ft18 ft
Clear height at target width7 ft7.33 ft
Show geometry CSV text

How to use this calculator

  1. Enter the span between eaves, reference height above the attic floor and length along the ridge.
  2. Enter each profile’s horizontal eave-to-break distance and both pitches. The break must fall before the middle of the span.
  3. Set the clear height, centered width and a vertical allowance for space occupied by the assembly or finishes.
  4. Compare the chart and dimensions. Open the geometry ledger to review or export both sets of coordinates and measurements.

The Formula

The mathematical logic powering this calculation is:

Each symmetric roof half runs horizontally from its eave to the midpoint. Upper run = half of span − lower run. Each slope input is rise per 12 horizontal units. Rise for each leg equals its horizontal run × slope ÷ 12. Add the lower rise to eave height for break height, then add the upper rise for ridge height. The two rises together give total rise above the eaves.
Roof-face lengths are the hypotenuses of the two run/rise triangles. Roof-face area equals twice the sum of those lengths times the ridge length. The roof-face area describes the four idealized planes from eaves to ridge, with no overhangs, laps, trims or waste.
For attic headroom, add the entered vertical allowance to the desired clear height. At or below eave height, the whole span clears. At the slope break, the available width is the distance between the two mirrored breakpoints. Between the eave and ridge, locate the intersection on the active slope by dividing the rise above its start by that slope. Subtract both equal insets from the span. At ridge height the intersection is a point, so width is zero. A line above the ridge intersects no profile.
The centered-width check finds its two outer edges inside the span and evaluates the roof height there. It subtracts the same vertical allowance from the height. An exact equality meets the target. Fit checks use the exact entered decimals before displayed dimensions are rounded.
Lengths are feet. Span is 0.03–200 ft, ridge length 0.01–1,000 ft, eave height 0–80 ft, allowance 0–20 ft, target height 0–200 ft and target width 0.01–200 ft. The lower and upper pitched sections must have positive runs, with the lower slope steeper than the upper. Pitches are 0.01–48 rise per 12. Entries accept up to two decimals. The solver models two symmetric reference profiles. Structural member sizing, joints, loading, local headroom requirements, egress and construction detailing are outside the model.

Worked Example

If you input:

  • Span, length, eave height: 24 ft, 30 ft, 1.50 ft
  • Target height, allowance, centered width: 7.00 ft, 0.50 ft, 16.00 ft
  • Profile A: 4 ft lower run, 18:12 lower slope, 6:12 upper slope
  • Profile B: 3 ft lower run, 24:12 lower slope, 4:12 upper slope

Result:

Profile A rises 6.00 ft in the lower leg and 4.00 ft in the upper leg to reach an 11.50 ft ridge above the attic floor. Profile B rises 6.00 ft then 3.00 ft to a 10.50 ft ridge. The 7.50 ft line falls exactly at both slope breaks. The clear widths are 16.00 ft and 18.00 ft, so both meet the 16.00 ft target.

Frequently Asked Questions

Where do I measure the slope break distance?

Measure horizontally inward from the eave to the point where the steep lower plane meets the shallower upper plane. Both eaves use the same distance for each symmetric profile.

How should I enter the slopes?

Enter their rises over 12 horizontal units. An 18:12 lower pitch and 6:12 upper pitch lift the roof 18 and 6 units, respectively, for each 12 units of horizontal run.

Does the clearance allowance change the roof geometry?

It raises the height line used for clearance. The roof break, ridge, face lengths and area stay based on the reference lines entered.

What happens when the height line is exactly at the break?

The intersection uses the two breakpoints. For a 24 ft span and a break 4 ft in from either eave, the clear width there is 16 ft.

Can I use the result to select rafters or approve living space?

The worksheet compares two geometric profiles. Member dimensions, engineered connections and use of an attic as habitable space depend on the actual assembly, loads and local requirements.

Similar Calculators